• Title/Summary/Keyword: 건물 에너지 절감

Search Result 204, Processing Time 0.025 seconds

A Consideration On The Surface Temperature Reducing Effect Of Green Roof System Flat Roof (옥상녹화 평지붕의 표면온도 저감효과에 대한 고찰)

  • Lee, Doo-Ho;Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.83-88
    • /
    • 2012
  • This study analyzed the measured value came out by the field test to verify the surface temperature reduction of the flat roof due to green roof, and confirmed the influence of the green roof based on it, and assessed the possibility of saving structures' energy and reducing $CO_2$ emission of structures. For the actual measurement, the differences of the average atmospheric temperature of the green roof and non-green roof flat roof were $8.67^{\circ}C$ and $0.787^{\circ}C$, and the average floor temperature gaps were $11^{\circ}C$ and $2.008^{\circ}C$ in October and November respectively. It was expected that if it's measured on around summer solstice that the temperature gets higher, the deviation of the surface temperature should be bigger, and it was confirmed that the green roof eventually raises insulating effect of structures and will influence on cooling and heating effects such as energy saving and insulating.

The Development of Average illumination Calculation Software (ZCM에 의한 평균조도 계산용 Software개발)

  • Yun, Mee-Rim;Sim, Sang-Man;Hur, Nam-Don;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.1-9
    • /
    • 2001
  • At the beginning of the lighting design, the improvement of lighting design method and standardization of the lighting design needed for saving lighting energy in the building design that can help to choose a high efficiency luminaire and it can calculate LLF(light loss factor). for that reason Average Illumination Calculation Software using ZCM for lighting designer was developed.

  • PDF

Trash Can with Automatic Segregation (자동 분리수거가 가능한 쓰레기통)

  • Yeo, Sang-Sam;Lee, Sang-Bin;Park, Jin-sol
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.165-166
    • /
    • 2020
  • 산업화 이후 무분별한 자원 개발로 인해 쓰레기 배출량은 증가하였으나 그 양을 감당할 쓰레기통의 개수는 부족하다. 그리고 쓰레기통이 있음에도 불구하고 시민의식 부족으로 인해 일반 쓰레기와 재활용쓰레기가 같이 버려져 있는 상태를 흔히 볼 수 있다. 작은 예로 자취하고 있는 대학생들 자취방 앞이나 상가 건물 앞에 분류되지 않고 아무렇게나 버려져있는 쓰레기들을 많이 볼 수 있다. 이는 환경 미화원이 직접 재분류를 하고 청소하는데 시간과 인력 비용이 낭비하게 된다. 본 논문은 이러한 문제점들을 개선하고 보완하고자 쓰레기를 자동으로 분리수거할 수 있는 '자동 분리수거가 가능한 쓰레기통'기술을 제안한다. 이는 분리수거율을 증가시키고 분리수거 다시 할 불필요한 시간과 인력과 예산을 줄일 수 있고 재활용된 자원을 사용하여 생산 자원을 줄여 원가 절감효과와 에너지 소비를 줄일 수 있다. 이로 인해 자원을 생산할 때 발생하는 탄소와 온실가스 방출량을 감소시켜 지구 온난화를 예방할 수 있다.

  • PDF

ZnO/Ag/ZnO Thin Films With Different Metal Layer Thickness (Metal Layer의 두께 변화에 따른 ZnO/Ag/ZnO 다층 박막의 특성 연구 Properties of Multi Layer)

  • Lee, Seung-Min;Lee, Sang-Ryeol;Kim, Hong-Bae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.352-352
    • /
    • 2013
  • 국내 에너지 소비량의 21.6%가 건물 분야에 소비되고 있다. 창호는 벽체에 비해 8~10배 이상 낮은 단열 특성을 가지기 때문에 열 손실량이 크다. 유리는 창호를 이루는 요소 중 가장 큰 면적을 차지하고 있으며, 창호의 단열성능을 2배로 향상시키면 30% 이상 건물의 에너지 절감 효과를 가질 수 있다. 창호의 단열 성능을 향상시키기 위해서 Low-e(emissivity) 기술 연구가 진행 중이다. 이번 실험에서는 RF 마그네트론 스퍼터링 시스템을 사용하여 XG 유리기판 위에 ZnO박막을 증착하고, evaporator 장비를 사용하여 metal층인 Ag를 증착하였다. 그리고 다시 한번 ZnO박막을 증착하였다. Low-e 연구에 활용할 수 있는지를 확인하기 위해 XRD, AFM, 투과도를 측정하였다. ZnO박막의 증착 조건은 초기압력 $3.0{\times}10^{-6}$ Torr, 공정압력 $2.0{\times}10^{-2}$ Torr, RF파워 30 W, Ar gas는 50 sccm, 증착온도는 상온으로 하였다. Metal층인 Ag를 증착하기 위해 evaporator의 증착 조건은 Rotate rate 2 rpm, voltage 0.3V, 공정압력 $5.0{\times}10^{-6}$ Torr이며, 변수로 Ag두께를 3,5,7,9,11,13,15 nm로 하였다. AFM 측정결과 Ag두께가 증가할수록 RMS roughness값이 높아졌으며, 최소 0.71 nm의 거칠기를 가지는 것을 확인하였다. XRD분석결과 37도 부근의 피크가 발생하여 ZnO 박막이 결정질 구조임을 확인할 수 있었다. 그리고 UV-Visible-NIR 분광 광도계를 이용하여 광학적 투과를 측정한 결과 Ag두께가 13 nm일 때 가시광 영역의 투과도가 최대 75%, 적외선 영역의 투과도가 최소 28%로 좋은 차단 특성을 가지는 것을 확인하였다. 위 결과들로 ZnO 박막이 Low-e 기술에 활용될 수 있음을 확인하였다.

  • PDF

Development of Lighting Control System Based on Location Positioning for Energy Saving (에너지 절약을 위한 위치측위 기반 조명 제어 시스템 개발)

  • Cho, Kyoung-Woo;Jeon, Min-Ho;Oh, Chang-Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.2968-2974
    • /
    • 2014
  • When lighting has installed indoor, we control lighting using human-detecting sensors for people who pass at night and places that are lack of quantity of light. However, malfunction can be caused by positions of inappropriate sensors, and in the case of passages of big buildings, it is a problem that even after a person pass, light apparatuses are turned on for a long time. In this paper, we propose lighting control system based on location positioning for energy saving that control lighting in accordance with passers's position through indoor location positioning. This system use the fingerprinting technology that is one of the location positioning technologies and RSSI data that is collected by a smart device. Using those, it can turn on only lightings that are included in the positioned location and reduce unnecessary power consumption. As a result of experiment, on condition that four people were existing and illumination was 308 lux, we assured reduction effect of 49 Wh.

Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System (건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석)

  • IN, JUNGHYUN;LEE, YULHO;KANG, SANGGYU;PARK, SUNGJIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

Recommended Practice for Demand Factor using Regression Analysis Theory depending on Power Consumption Characteristics in Commercial Buildings (업무용빌딩의 전력소비 특성을 고려한 회귀분석이론을 이용한 수용률 기준 설정)

  • Kim, Se-Dong;Shin, Hyo-Seop;Kim, Soo-Gil;Oh, Kie-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.217-222
    • /
    • 2004
  • 고도 정보화 사회의 진전으로 전기에너지의 소비는 급격히 증가하고 있다. 특히 업무용 빌딩과 같은 전력다소비 건물에서는 전력의 효율적 이용에 의한 에너지절감은 물론 설계 단계에서의 합리적인 전기설비 설계가 요청되고 있다. 현재 우리나라의 기후 특성과 전력소비 특성을 고려한 합리적인 전기설비 설계를 위한 기초 자료가 매우 미흡한 실정이다. 본 연구에서는 합리적인 수용률 기준을 설정하기 위하여 사무소용 빌딩의 전력 소비 특성을 조사 분석하였고, 아울러 전기설비설계사무소에서 적용하고 있는 수용률을 조사 분석하였다. 조사된 자료 전체의 특징과 중심적인 경향을 알아내기 위해서 평균값, 중앙값, 표준편차, 최대 값, 최소 값, 회귀모형식, 최소제곱 평균오차 등의 확률 통계적 파라미터들을 수용률 기준 설정을 위한 특징 파라미터로 선택하였다. 그리고, 데이터의 신뢰성을 비교 분석하기 위하여 선형적인 방법과 비선형적인 방법으로 그 경향을 추정하여 곡선으로 나타내었다. 이러한 방법에 의하여 얻어진 분석 자료를 이용하여 적정 변압기 용량 설정을 위하여 데이터베이스화하였고, 변전설비용량의 합리적인 설계를 위하여 수용률 기준 적용시에 필요한 자료로 활용할 수 있으리라 사료된다.

  • PDF

Experimental Study of Cooling Energy Saving Verification Using Blinds and Phase Change Material(PCM) (창호 블라인드와 상변화물질 적용에 의한 냉방 에너지 사용량 절감효과에 대한 검토 연구)

  • Song, Young-Hak;Kim, Ki-Tae;Koo, Bo-Kyung;Lee, Keon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.26-31
    • /
    • 2014
  • This study looks into changing building energy use by application of phase change material (PCM). PCM does not need extra energy for operation and is used for reducing building energy use and, CO2 output by displaying semi-permanent effects after installation. It also is able to avoid the maximum electric power time-zone by inducing a time lag phenomenon of cooling and heating loads with high thermal capacity using latent heat. To verify the efficiency of blinds and PCM, tests about the PCM operation mechanism using air conditioning machinery and nocturnal panel cooling were done. In the test results of the case using PCM installation, a $45^{\circ}$ blind angle with machinery air conditioning and nocturnal panel cooling at the same time shows a 22 percent energy saving effect against general space. The test results of each case were compared and analyzed based on the blind and window opening settings. Finally, the energy reduction of existing buildings using PCM application was reviewed based on the final measurement results.

Recommended Practice for Demand Factor/Diversity Factor with respect to Power Consumption Characteristics in Commercial Buildings (업무용 빌딩의 전력소비 특성을 고려한 수용률/부등률의 적용에 관한 연구)

  • 김세동
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.74-79
    • /
    • 2002
  • This paper shows a reasonable design standard factor in commercial buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, load characteristic, etc., for 23 commercial buildings. With a rapid growth of national economics with the development of intelligence society , electrical energy consumption markedly increased Expecially, it is increased electrical energy consumption in the commercial buildings and thus an energy conservation through efficient use of electricity became more important In our country, the estimation of demand factor and electric equipment capacity are not properly and thus the application of these factors are confusing and different in each electric design of the field.

On Low-Carbon Green Waterfront Cities (해외 저탄소 녹색수변도시)

  • Kwon, Yong-Woo;Wang, Kwang-Ik;Yu, Seon-Cheol
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Low-carbon green waterfront cities for overseas cases were reviewed to propose the direction for Korea. The implications suggested include energy saving by resource circulation, compact land use planning, transit oriented development, and utilization of renewable energy. These in turn suggest the following implementations; (1) Energy saving according to compact city, complex land use, and transit oriented development, (2) Renewable energy use in buildings and daily lives, (3) Expansion of green space for carbon mitigation and improved quality of life, and (4) Water and resource circulation system. We finally discussed that development of the green waterfront cities in Korea requires the fundamentals of low-carbon green waterfront cities achieved by overseas cases study and technical investigation.