• Title/Summary/Keyword: 건물영향분석

Search Result 814, Processing Time 0.025 seconds

Investigation of Optimal Outrigger Location of High-rise Offset Outrigger System (초고층 오프셋 아웃리거 구조시스템의 최적 아웃리거 위치에 대한 탐색)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.16-24
    • /
    • 2017
  • The purpose of this paper is to search the optimal location of offset outrigger system in high-rise building after a structural schematic design of 80 stories building was conducted, making use of MIDAS-Gen. In this research, the key factors of analysis study were column stiffness, outrigger position in plan and outrigger location in height. For the aim of finding out the optimum position of offset outrigger system in tall building, we studied the lateral displacement in top floor which is the very essential variables in the structural design of high-rise building. The results of study showed that the column stiffness, the outrigger location in plan and outrigger location in height had an effect on the optimal position of outrigger system. Also, it is indicated that the research results can be useful in acquiring the structural design materials for seeking the optimum position of offset outrigger system in tall building.

Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure (의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석)

  • Lee, Sangmoon;Cho, Jinkyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.

Source and Sink Relationship in Diallell Grafting among Sweet potato Cultivars (고구마 품종 간 이면접목에 의한 생산능력과 저장능력)

  • 남상영;정승근;김인재;김민자;이철희;김태수
    • Korean Journal of Plant Resources
    • /
    • v.14 no.2
    • /
    • pp.89-93
    • /
    • 2001
  • To obtain the basic information for varietal improvement and cultural practice, source and sink relationship in the diallel grafting was analyzed among five sweet potato cultivars, Yulmi, Shinyulmi, Gunmi, Hongmi and Seonmi, whose source and sink capacities are different one another. General grafting effect(GGE), specific grafting effect(SGE) and reciprocal grafting effect(RGE) of top weight, tuberous root weight and total weight showed considerable differences. Grafting decreased total dry weight but its effect was different among grafting combinations. Growth and dry matter production of top were affected more by scion, while those of underground were influenced more by stock. Shinyulmi which has great potential source and sink capacities resulted the highest total dry weight, while Hongmi and Yulmi which have low potential source capacity resulted the lowest total dry weight.

  • PDF

Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings (초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.89-94
    • /
    • 2009
  • The stack effect in high-rise buildings is expected more significant at nights in winter due to the large temperature difference between the inside and outside of the buildings. However, the existence of large openings such as natural ventilators on the floor may effect the position of neutral plane, smoke spread at fire and thus obstruct the door openings for rescue. In this paper, the vertical and horizontal pressure distribution with different openings of natural smoke ventilators was experimentally analyzed by investigating pressure differentials.

Shaking Table Tests of a 1/4-Scaled Steel Frame with Base Isolators (1/4축소 철골구조물을 이용한 건물 기초분리장치의 진동대실험)

  • 송영훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.39-48
    • /
    • 1997
  • New form of base isolators made of steel spring coated with both natural and artficial rubber were manufactured and tested for material properties. Shaking table experiments were performed using a model structure attached with the bearings. The model structure used in the test is a 1/4 scaled steel structure, and earthquake records were used to check the lateral and vertical stability and effectiveness of the isolators. According to the results all three types of isolators turned out to be effective in reducing the acceleration induced by the earthquake vibration.

  • PDF

Analysis on the Impact of Load Factors in Building Energy Simulation Affecting Building Energy Consumption (에너지시뮬레이션에서의 부하요소가 건물에너지사용량에 미치는 영향 분석)

  • Yoon, Kap-Chun;Jeon, Jong-Ug;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.71-78
    • /
    • 2011
  • The goal of this study is to analyze the impact of load factors on building energy consumption by using EnergyPlus program. We selected a campus building and monitored energy consumption from January 2009 to November 2010. First, we simulated energy consumption basically with weather data, building heat gain and EHP performance data. And then we simulated energy consumption with three additional parameter(infiltration, OA control and schedule). Simulation results are verified by MBE and Cv(RMSE) proposed by M&V guideline 3.0. Simulated total energy consumption was 104.3% of measurements, 4.33% of MBE, and 13.62% of Cv(RMSE). Results show infiltration and schedule were revealed as the most dominant factor of heating energy consumption and of cooling energy consumption, respectively.

초고층아파트 최적 설비시스템 개발 -급수설비시스템 개발을 중심으로-

  • 이대원;김태형;최도혁;김종필
    • 월간 기계설비
    • /
    • s.35
    • /
    • pp.84-96
    • /
    • 1993
  • 본 연구는 '초고층 아파트 최적 설비시스템 개발'의 제2차년도 연구로서 아직까지 국내에서 확립되어 있지 않은 초고층 아파트 급수설비 시스템 및 수격방지 시스템의 모델정립과 연돌효과에 의한 열손실 추정 및 적정 설계 지침 설정에 관한 연구를 수행하였다. 이를 위하여 이론 해석 및 현장실험을 수행하였고, 결과분석을 통하여 최적화 설계방안도 아울러 도출하였다. 급수설비 분야에서는 각종 급수 시스템의 해석 및 비교를 통한 효율적인 시스템의 설계 및 선정방법을 제시 하였고, 실제 초고층 아파트에 대한 수격현상 해석 및 실험을 통하여 수격작용의 영향을 감소시킬 수 있는 설계방안을 검토하였다. 또 입주중인 초고층 아파트 현장에서의 실측을 통하여 건물의 높이에 따라 불균일한 틈새가 있는 일반적인 경우에 대한 모델을 정립하였고, 수치해석을 통한 수직통로 내의 실제 열유동 현상을 정량화하고 설계지침을 제시하였다. 결과로서 각종 급수시스템의 해석을 위한 프로그램을 개발하였고, 수격의 발생을 억제하기 위한 최적 밸브 폐쇄형태를 제시하였으며, 초고층 건물의 내외부에 형성되는 압력차와 유인풍량 및 열손실량 사이의 관계식을 얻었다.

  • PDF

A Study on the Impact Factor of Sunlight and View by Apartment Building in its Neighboring Area (focused on the variation of building height) (공동주택에 의한 인접지역의 일조 및 조망 영향에 관한 연구 - 건물 높이 변화를 중심으로 -)

  • 김용이;최정민
    • Journal of the Korean housing association
    • /
    • v.14 no.6
    • /
    • pp.51-58
    • /
    • 2003
  • When apartment buildings are builed and re-builded, they tends to be taller. This tendency causes the problems for solar access and view in the neighboring area. So the impact factor of sunlight and view by apartment building in its neighboring area is examined. The results of this study are as follows: When analyzing sky view by dividing the sky vault into the differential area, the analysis of view can be efficient. The shorter the apartment building, the more the continuous solar access time. And the taller the building, the more the accumulated solar access time. As the height of building is taller and it is farther from the border of apartment building, view ratio, sky view ratio, and form ratio are increased. It implies that the slimmer the building, the more the visual environment can be improved.

Vertical Shortenings in a High-rise Building during Construction using Wireless Measurement System (무선 자동 계측 시스템을 이용한 고층건물의 시공 중 수직 축소량 모니터링)

  • Choe, Se-Un;Park, Hyo-Seon
    • Computational Structural Engineering
    • /
    • v.29 no.2
    • /
    • pp.18-23
    • /
    • 2016
  • 본 기사에서 소개한 무선 센서 네트워크 시스템을 이용한 고층건물의 축소량 자동 무선계측 시스템은 현장 적용을 통해 시스템의 적용성과 효율성을 확인하였다. 이는 무선 자동 계측이 가능하기 때문에 원거리에서 계측값 확인 및 관리가 실시간으로 가능하며, 축소량 업무와 관련한 인력 등의 비용을 감소시킬 수 있다. 또한 무선 센서 노드를 적용하여 사용 케이블을 최소화하였기 때문에 공사 작업에 대한 영향을 최소화하는 이점을 가진다. 무선 자동 계측은 다수의 센서 관리를 용이하게 할 뿐아니라, 다량의 데이터의 분석을 신속하게 할 수 있는 장점을 가지기 때문에, 축소량 기술을 축적하고 향상시키는데 기여할 수 있다.

Verification of FE models for various types of structures using measured dynamci properties (동특성 계측을 통한 건물 구조형식별 FE 구조해석 모델의 검증)

  • Kim, Ji-Young;Park, Jae-Keun;Cho, Ja-Ock;Yu, Eun-Jong;Kim, Dae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.598-601
    • /
    • 2011
  • 동적응답과 하중을 정확히 산정하기 위해서는 구조물의 동적특성을 정확히 평가하는 것이 중요하기 때문에, 현재 대부분의 경우 FE 모델을 이용한 Modal 해석을 dldydg하여 동특성을 평가하고 있다. 그러나 실제 건물의 계측결과와 동적특성의 해석결과가 많은 차이를 나타내고 있으므로 해석결과의 신뢰성을 향상하기 위해서는 FE 모델에 대한 Calibration이 수행될 필요성이 있다. 이 논문에서는 초고층, 아파트, 대공간 구조물에 대한 계측을 수행하고 이 결과를 바탕으로 동특성을 정확히 예측하기 위한 FE 모델의Calibration 과정을 제시하였다. 이 결과를 바탕으로 동적특성의 정확성이 풍동실험결과의 신뢰성에 미치는 영향을 분석하였다.

  • PDF