• Title/Summary/Keyword: 건물성능평가

Search Result 539, Processing Time 0.025 seconds

An Experimental Study on the Estimation for the Flow Coefficient of Elevator Hoistway (엘리베이터 승강로의 유량계수 산정에 관한 실험 연구)

  • Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • Recently, evacuation safety of building resident become the major concern, as the building has been higher and more complicated. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is progressing. This study shows the flow coefficient of hoistway when elevator is moving. The results of this study can be used for the study of elevator piston effect as basic data. Experiments were performed in 5 different hoistways at 3-story and 2-story buildings. According to the result of flow coefficient experiments, average flow coefficient is 0.954. Considering the $4{\sigma}$ to guarantee 99.99 % reliance, it is 0.86. This result is 3.6 % bigger than 0.83 that Klote and Tamura suggested. It represents that the maximum critical pressure is decreased about 7 % on the same condition of elevator and elevator shaft. When the smoke control performance of high-rise building is evaluated, the result is significant economically by applying a more realistic and less value of elevator piston effect.

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.

Estimation of Interstory Drift for Moment Resisting Reinforced Concrete Frames Using Equivalent SDOF System (등가 1자유도계를 이용한 철근콘크리트 골조건물의 층간변위 응답 산정)

  • Kang, Ho-Geun;Jun, Dae-Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.25-33
    • /
    • 2004
  • To evaluate the seismic capacity of a multistorey building structures in performance based seismic design, it is needed to convert MDOF model into equivalent SDOF model. This paper presents predictions for interstory drift of multistorey structures using method of converting a MDOF system into an equivalent SDOF model. The principal objective of this investigation is to evaluate appropriateness of converting method through performing nonlinear time history analysis of a multistory building structures and an equivalent SDOF model. Comparing the interstory drift of multistorey structures calculated by time history analysis and those evaluated by an equivalent SDOF model, the adequacy and the validity of converting method is verified. The conclusion of this study is following; A method of converting a MDOF system into an equivalent SDOF model through the nonlinear time history response analysis is valid. Inelastic first mode shapes are expected to be more accurate than elastic first mode shapes in obtaining interstory drift of multistorey structures from equivalent SDOF model.

Compressive and Adhesive Strengths of Mortars using Re-emulsification Type Polymer and Ultra-Rapid-Hardening Cement (재유화형 분말수지와 초속경 시멘트를 혼입한 모르타르의 압축강도 및 접착강도 특성)

  • Lee, Kwang-Il;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.329-335
    • /
    • 2018
  • The objective of this study is to develop a mortar mixture with high workability and adhesive strength for section jacketing in seismic strengthening technology of existing concrete structures. To achieve targeted requirements of the mortars (initial flow exceeding 200 mm, compressive strength of 30MPa, and adhesive strength exceeding 1MPa), step-by-step tests were conducted under the variation of the following mixture parameters: water-to-binder ratio, sand-to-binder ratio, polymer-to-binder ratio, dosage of viscosity agent, and content of ultra-rapid-hardening cement. The adhesive strength of the mortars was also estimated with respect to the various surface treatment states of existing concrete. Based on the test results, the mortar mixture with the polymer-to-binder ratio of 10% and the content of ultra-rapid-hardening cement of 5% can be recommended for the section jacketing materials. The recommended mortar mixture satisfied the targeted requirements as follows: initial flow of 220 mm, high-early strength gain, 28-day compressive strength of 35MPa, and adhesive strength exceeding 1.2MPa.

Progressive Collapse Resisting Capacity of Moment Frames with Viscous Dampers (점성감쇠기가 설치된 모멘트골조의 연쇄붕괴 저항성능)

  • Kim, Jin-Koo;Lee, Seung-Jun;Choi, Hyun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.517-524
    • /
    • 2010
  • In this paper the progressive collapse resisting capacity of steel moment frames with viscous dampers was evaluated by nonlinear dynamic analysis. The effects of dampers installed in steel beam-column sub-assemblages with varying natural period and yield strength were evaluated after sudden removal of a column. According to the parametric study the vertical displacement general decreased as the damping ratio of the system increased, and the dampers were effective both in elastic and elasto-plastic systems. The nonlinear dynamic analysis results of the 15-story analysis models showed that the decrease in vertical deflection of the structure with 9m span length, which showed larger deflection, was more predominant than that of the structure with 6m span length.

A study on indoor navigation system using localization based on wireless communication (무선통신기반 위치인식을 이용한 실내 내비게이션 시스템에 관한 연구)

  • Kim, Jung-Ha;Lee, Sung-Geun;Kim, Jong-Su;Kim, Jeong-Woo;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.114-120
    • /
    • 2013
  • Recently, navigation systems based on wireless communication have been applied to the internal structures such as building or ship. If a stable azimuth information is obtained, these systems can effectively guide the direction of the user's progress through the information and then can improve the performance of guidance. Since conventional method which has acquired an azimuth information using geomagnetic and acceleration sensor(azimuth sensor hereafter) is sensitive to the effects of the magnetic field, it has unstable error range according to the surrounding environment. In order to improve these problems, this paper presents a new relative azimuth estimation algorithm using the displacement of a mobile node and its rotation angle based on Wireless communication. For the performance assessment of the proposed algorithm, experiments using rotating arm are performed and the results are confirmed that the proposed system can estimate the relative azimuth without using additional sensors.

Performance assessment of multi-hazard resistance of Smart Outrigger Damper System (스마트 아웃리거 댐퍼시스템의 멀티해저드 저항성능평가)

  • Kim, Hyun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.139-145
    • /
    • 2018
  • An outrigger system is used widely to increase the lateral stiffness of high-rise buildings, resulting in reduced dynamic responses to seismic or wind loads. Because the dynamic characteristics of earthquake or wind loads are quite different, a smart vibration control system associated with an outrigger system can be used effectively for both seismic and wind excitation. In this study, an adaptive smart structural control system based on an outrigger damper system was investigated for the response reduction of multi-hazards, including seismic and wind loads. A MR damper was employed to develop the smart outrigger damper system. Three cities in the U.S., L.A., Charleston, and Anchorage, were used to generate multi-hazard earthquake and wind loads. Parametric studies on the MR damper capacity were performed to investigate the optimal design of the smart outrigger damper system. A smart control algorithm was developed using a fuzzy controller optimized by a genetic algorithm. The analytical results showed that an adaptive smart structural control system based on an outrigger damper system can provide good control performance for multi-hazards of earthquake and wind loads.

A Study on Comparison and Analysis of Revision Building Rating System for Environment-friendly Residential Building (국내 친환경 공동주택의 활성화를 위한 개정 건물 성능 평가제도 비교 연구)

  • Park, Kyung Soon;Kim, Chul;Kwon, Moon Hee
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.19-28
    • /
    • 2010
  • As design tools, building performance certification systems can be applied to provide adequate guidelines on design process to create environment-friendly buildings. Domestic certification systems of residential building took effect by doing supply to designers and contractors from affiliated organization of governments in the early 2000s. As a result, Building Energy Rating System, Apartment Performance Rating System, Green Homes and other means to promote green designs have been operated. International trends of applying certification systems were started in the early 1990s as forms of LEED in USGBC, BREEAM in BRE, GBTool Canada. These systems aim to evaluate building performance in line with the Climatic Change Convention and realize sustainable building design. In 2009, residential buildings accounted for the largest portion of the internal real estate market with 67.9 percent according to the National Statistical Office data. And for 18 years since 1991, apartments among constructed residential buildings have ranked top taking up 77.7% as of 2009. Apartment performance evaluations accordingly are to promote to constitution of improving tenant quality of life, the residential environment and saving energy and resources in the internal building market. The purpose of this study is to compare and analyze valuation bases of each sector in evaluation systems of residential buildings at home and abroad to upgrade current systems through reflecting the characteristics of residential buildings. Implementation of this study basically include comparison of valuation bases and partial analysis on properties of rating systems to suggest requisites for improvement in building performance certification.

Evaluation of Pull-Out Strength of Connections with Roof Cladding using Honey Comb Panel Secured Cool Roof Performance (Cool Roof 성능을 확보한 Honey Comb Panel 지붕 접합부의 인발 성능 평가)

  • Lee, In Ho;Park, Sang Woo;Ko, Kwang Il;Chung, Mi Ja;Lee, Eun Taik
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.139-149
    • /
    • 2016
  • Roof cladding of buildings are required for the measures about the 'screw pull-out' which causes the casualties and the property damage by typhoons. In this study, the pull-out resistance was increased by increasing the penetration depth of the screw installing a ironware called 'insert nut' on the roof cladding frame. Tensile tests were conducted to compare the pull-out strengths of a general screw-joint and a nut insert joint. Roof cladding that is actually being used in the field was produced using the 'solid work' and then the roof claddings using a general screw-joint and a nut insert joint were compared by a static test and dynamic test.

Performance analysis of campus wireless LAN in outdoor environment (실외환경에서 캠퍼스무선랜의 성능분석)

  • Kang Min-soo;Kim Myeong-hwan;Park Yeoun-sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.4
    • /
    • pp.753-757
    • /
    • 2005
  • Wireless LAN was developed by alternative of LAN and because establishment was easy, have used into special field and special expenditure. Recently, Standard and a technology developed by leaps and bounds. Present is used into purpose of the Building to Building or wide connection etc. and relay of the high speed Internet and usage of picture communication that require multimedia band width. Specially, campus wireless LAM is thought that must secure radius $100\;\~\;200\;m$ dimension at the minimum 10Mbps speed as Internet transit trunk. But, there is difference as degressive here. In this paper, wireless LAN measured for effectiveness proof as Internet transit trunk in actuality utilization environment. Proved that should compose IEEE802.11b as AP more than minimum 3 when compose network to base as measuring result. Hereafter, there is the purpose that achieve performance evaluation of wireless UM in marine environment.