• Title/Summary/Keyword: 건물면적

Search Result 683, Processing Time 0.026 seconds

Studies on Productivity in Meadow Fescue ( Festuce pratensis Huds. ) V. Vertical distribution of leaf area and dry matter production (Meadow fescue의 건물생산량에 관한 연구 V. 엽면적의 수직적 분포와 건물생산)

  • 이주삼;정충섭
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.4 no.3
    • /
    • pp.187-193
    • /
    • 1984
  • Using the stratifying clip method, we examine the differences in vertical distribution of leaf area and its relationships with dry matter production were investigated in the primary swards of six varieties. The results obtained were as follows: 1. The varieties could be classified into 4 different types according to their of vertical distribution of leaf area within the canopy. Thus, M had a greater leaf area distribution in the base layers and became smaller towards the upper layers, Leto, First and Bundy had the leaf area distribution which was most abundant in the middle layers and became smaller towards the base and the upper layers, Tammisto had a greater leaf area distribution in the middle layers and intensively distributed to the upper layers, and Trader had the relatively uniform leaf area distribution over all layers. 2. Effective leaf area index(ELAI) correlated with leaf area index(LAI), dry weight of plant(DW), stem weight of plant(SW) and stem area index(SAI). 3. The variety with the heading tiller type had the effective leaf area intensively distributed to the upper layers of canopy, but the vegetative type showed a high ratio of effective leaf area index. 4. Varietal differenced was found between the effective leaf area and specific leaf weight(SLW) in each stratum above the layer indicating the highest leaf area density within the canopy. M and Trader had a highly negative significant correlation, but the other varieties was not significant correlation.

  • PDF

A new type liquid damper with adjustable natural frequencies (고유진동수 조절이 가능한 새로운 형태의 액체댐퍼)

  • Lee, Hye-Ri;Min, Kyung-Won;Park, Ji-Hun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.161-165
    • /
    • 2011
  • 본 논문에서는 고유진동수 조절이 가능한 새로운 형태의 액체댐퍼를 개발하였다. 동조댐퍼는 구조물의 설계단계에서 응답평가를 통해 필요성이 요구된다. 건물은 설계단계에서 고유진동수와 시공 후 고유진동수가 상이하다. 액체댐퍼의 형태는 설계단계에서 건물의 고유진동수를 동조시킬 수 있도록 설계되기 때문에 고유진동수가 고정이 될 수 있다. 본 연구에서는 제안한 댐퍼의 전체적인 형태는 기존의 Liquid Column Vibration Absorber(LCVA)와 같다. 기존의 LCVA는 시공 후 건물의 고유진동수에 동조시키기 위해 물높이를 조절하나 층고 때문에 제한이 있다. 우리가 제안한 새로운 형태의 액체댐퍼는 물높이 조절 뿐 아니라 수직관의 면적을 조절하여 고유진동수를 조절 할 수 있도록 개발하였다. LCVA의 수직관을 일정한 면적의 독립된 셀로 나누었으며 이 셀을 각각 밀폐시킬 수 있도록 하였다. 밀폐된 셀 안으로는 공기압력에 의해 물이 차지 않고 차 있는 물도 움직이지 않게 된다. 밀폐된 셀의 개수를 조정하여 수직관의 면적이 조절하여 고유진동수를 변화시킬 수 있다. 제작된 액체댐퍼의 밀폐된 셀 개수를 조절하여 진동대 실험을 통해 댐퍼의 고유진동수를 파악하였다. 실험으로 나온 고유진동수와 이론적으로 산정한 고유진동수를 비교하여 댐퍼의 사용성을 평가하였다. 개발된 액체 댐퍼의 수직관의 면적 조절을 통해 고유진동수 조절이 용이하여 실제로 사용이 가능함을 확인할 수 있었다.

  • PDF

초고층건물에서 발생되는 굴뚝효과 방지대책

  • 권용일;박명식
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.12
    • /
    • pp.32-38
    • /
    • 2004
  • 초고층건물의 건설이 증가되고 있지만 건물외파와 출입문의 기밀도가 낮게 유지될 때, 이러한 누설면적과 층별로 구획할 수없는 수직샤프트(계단실 등)와 직렬로 배치될 경우, 필연적으로 발생하게 되는 굴뚝 현상(stack effect)의 발생원인과 차압크기 산정하는 방법 및 예방대책을 소개하고자 한다.

  • PDF

울진 1,2호기 Cavity에 대한 노심용융물 고압분출 실험 연구

  • 김상백;박래준;김희동;김도형;이규정
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.569-574
    • /
    • 1997
  • 프랑스 가압경수형 원전인 울진 1,2호기 cavity의 격납용기 직접가열에 대한 특성을 분석하기 위하여 노심 용융물 고압분출 실험 연구를 수행하였다. 울진 1,2호기 격납건물은 국내의 Westinghouse와 CE형 원전과 달리 원자로용기 하부 cavity내 수평통로에 의한 출구가 없어 원자로용기 외곽의 환형통로를 통해 cavity와 격납건물 상부 대기와 직접 연결되어 있는 특성을 가지고 있다. 본 연구에서는 환형통로 면적, 파손 직경 용융물 질량 등에 따라 원자로용기 압력을 변화시키면서 용융물을 물, 증기를 질소기체로 각각 모의하여 실험을 수행하였다. 실험결과, 노심용융물 고압분출에는 원자로용기 파손 직경이 많은 영향을 미치는 것으로 나타났고 환형통로 면적과 용융물 질량은 큰영향을 미치지 않는 것으로 나타났다. 또한 환형통로 면적의 감소는 노심용융물 고압분출시 cav의 압력을 다소 상승시키는 결과를 보여주었다. 본 실험 연구에서 노심용융물 고압분출에 많은 영향을 미치지 않는 것으로 나타난 환형통로 면적에 대해서는 종합적으로 분석하는 추가 실험 이 필요하다.

  • PDF

Kyobo Tower (교보타워)

  • Yoon, Chun-Ho;Lee, Hee-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.8-20
    • /
    • 2003
  • 2003년 4월 대지면적 2,047평, 지하8층, 지상25층, 연면적 28,047평으로 지어진 이 건물은, 서울 강남을 상징하는 회색빛 상업건물들을 압도하는 듯한 붉은색 벽돌타일관 두개의 타워, 그 사이를 이어주는 유리벽 통로로 구성되어 한국 건축문화의 새로운 장을 연 건축물이다. (중략)

A Study on the Correlation between the Building Perimeter and Safety Management Cost (건물의 외주길이와 안전관리비의 상관관계 분석에 관한 연구)

  • Han, Bum-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.4
    • /
    • pp.359-370
    • /
    • 2022
  • Despite continuous efforts to reduce on-site safety accidents, the construction industry remains a high-risk sector with a high rate of fatal accidents. Design for Safety(DFS), which manages safety risk factors at the design stage, is being used as a method to lower the construction safety accident rate. However, due to limited knowledge, designers are unaware of the design-results risks during the different of the project lifecycle, including construction, operation, and maintenance. Effective DFS can be conducted if the designer understands the effect of the building shape on the safety accident rate and corresponding safety management cost(SMC). The cost of safety facilities such as fall prevention nets and safety fences will vary depending on the shape of the building. This study analyzes the outer perimeter length's impact on SMC. Following the data collection from 21 projects for this study, an analysis was conducted using the independent variables of the building perimeter(BP), building shape factor(BSF), and building area(BA), the dependent variable of SMC. The correlation R2 was found to be 0.876, 0.801 and 0.792 between the BP and SMC, BSF and SMC, BA and SMC, respectively, indicating that these factors were closely related.

Principal Component Analysis for the Growth Data of Rice (주성분분석을 이용한 수도의 생장해석)

  • Hahn, Weon-Sik;Chae, Yeong-Am
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.31 no.2
    • /
    • pp.173-178
    • /
    • 1986
  • Principal component analysis was used for ana1zing growth data to know the relationship between growth characteristics and yield as well as its components. The first principal component accounted for average time of the specific leaf area sampled, leaf area index, and dry weight, and the second component for the position of the changing point of growth characteristics. The component scores were more affected by the nitrogen level than variety. Yield were affected by fertility ratio and number of spikelets per hill which have close relation with the component score of leaf area index and dry weight per hill.

  • PDF

CASE Study: Policy implications of HAZUS analysis

  • Kim, Yong-Gyun
    • Magazine of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.48-52
    • /
    • 2008
  • 대형태풍 카트리나가 준 주요 교훈 중의 하나는, 위험도 분석에 기반한 종합적인 재해경감 프로그램의 중요성이다. 미국에서는 이를 위해 다양한 위험도 분석(risk analysis) 프로그램 개발에 노력해 왔다. HAZUS(Hazarda-US) 프로그램은 대표적인 자연재해 예측 시스템으로서, 위험요인 파악(hazard identification), 지역사회의 취약성 분석(vulnerability of the society), 그리고 피해결과예측(loss estimation)의 세 가지 요소로 구성된다. 1992년 지진을 대상으로 개발된 이 프로그램은 현재, 지진 홍수 허리케인 윈드에 대해 피해예측을 할 수 있는 HAZUS-MH MR3가 사용 중에 있다. FEMA에서는 주정부에서 HAZUS를 활용, 피해 예측에 기반한 재해경감 정책을 추진할 수 있도록 다양한 재정적 기술적 지원을 하고 있다. 이에 따라, 2004년 머릴랜드 주에서는 미국 최초로 주 전역에 걸친 홍수피해 예측을 실히하고 이를 바탕으로 다양한 경감정책을 추진하였다. 머릴랜드 주정부에서 Salisbury 대학에 의뢰하여 수행한 홍수 피해 예측 과정은, 조사구역 및 위험요인(홍수) 결정, 사용 데이터 확정, 수문학적 분석, 수리학적 분석, 피해예측(건물 용도별 피해면적, 건물 용도별 피해액, 건물 재질별 피해면적, 건물 재질별 피해액, 지역의 경제학적 피해)의 과정으로 수행되었다. 홍수피해 예측 결과, 100년 빈도 홍수가 재현될 경우, 주 전체 면적 중 13%이상의 지역에서 약 80조 이상의 피해액이 예측됨에 따라, 종합적인 재해경감 대책의 필용성이 제기되었다. 이에 따라, 머릴랜드 주정부에서는 홍수피해예측 결과를 토대로, 주정부 재해경감 예산 재분배, 홍수터 보호, 건물규제 강화, 토지이용계획 재조정 등 보다 과학적이고 종합적인 재해경감 프로그램을 추진하였다. 머릴랜드 주정부의 이번 연구는 주정부로서는 최초로 HAZUS를 활용하여 주 전역에 걸친 피해예측을 실시한 것으로서, 피해예측 시스템이 어떻게 주정부의 과학적 피해경감 프로그램에 기여할 수 있는 지를 보여주는 사례이다.

  • PDF

Analysis of the Heating and Cooling Energy Load for Facade Variation in Plant Factory (식물공장의 건물 형태에 따른 냉난방부하 분석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.569-572
    • /
    • 2012
  • 식물공장의 다양한 건물형태에 따른 냉난방부하의 차이를 DesignBuilder를 이용하여 해석하였다. 엽채류 중 상추의 생육 적정온도인 $20^{\circ}C$를 실내온도로 설정하고 식물공장 외벽에 단일창호를 적용하여 온실형태에 따른 냉난방부하 변화를 계산하였다. 보광이 없는 건물자체의 냉난방부하를 계산한 결과 KNU 식물공장 단위유닛과 반원 온실형 식물공장이 냉방부하가 가장 적었다. 보광 적용 후에는 전반적으로 KNU 식물공장 단위유닛과 직사각형 식물공장이 양호한 냉난방 성능을 보여주었다. KNU 식물공장 창호의 면적이 와이드 스팬형보다 크기 때문에 건설비용의 증가가 예상되지만 회전형 스마트 조명 제어시스템을 적용하게 되면 재배면적을 넓히고 공간활용에 유리하다. 또한 LED 사용량을 줄일 수 있어 냉방부하와 보광에 드는 비용을 절감할 수 있다.

  • PDF

Research regarding the proposal of the site generation that applied GIS technology due to city spatial structure analysis (도시공간 구조 분석을 위한 GIS기술을 이용한 대지선 산출프로그램 개발에 관한 연구)

  • Kwon, Chang-Hee;Shin, Seung-Jung;Jung, Jong-Soo;Na, Jong-Wha;Bae, Sang-Hyun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05b
    • /
    • pp.867-870
    • /
    • 2003
  • 현재 한국과 일본은 실제 대지선을 디지털 맵으로 정비되어 있지 않은 상황에 따라 실 대지선에 대한 근접한 이론적 대지 선을 산출 및 작도하여 시가지 분석에 조력의 역할을 도모하게 하는 것을 목적으로 본 연구를 수행하였다. 도로와 건물간의 관계와 건물과 건물간의 위상관계를 감안하고 GIS 기술을 적용하여 이론 대지면적을 추출하고 실제측량에 의한 실제 대지와의 차의 정도를 파악하여 시가지 공간분석에 있어서의 필수 불가결한 평면적인 토지이용상황을 나타내는 지표인 건폐율을 산출하는데 필수 불가결한 대지면적산출의 정합성을 증명하였다.

  • PDF