• Title/Summary/Keyword: 개폐

Search Result 1,128, Processing Time 0.03 seconds

Measuring Changes of Dominance in Designs of Mobile Phones (휴대폰 디자인에 있어서 지배성 변화 측정)

  • Park, Sang-June;Lee, Yu-Ri
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.91-102
    • /
    • 2010
  • This study investigates the dominant degree of product design factors through the process of change of design factors. The previous research suggested a concrete measurement method of dominant designs, but it did not investigate empirically the degree of dominance due to the limited data for changes of designs. In this research, thus, after collecting design data of mobile phones and we measured the dominance and structure change of the designs by year. The analyses showed the following two things. First, in design factors of mobile phone the dominance on the body form and the edge grows more and both of them as dominant design factors tend to converge into the rectangular body form and the round edge, respectively. Second, the dominance on other design factors(e.g. the button type, the open type, whether or not to have digital multimedia broadcasting(DMB) and video telephony functions, the combination of colors and the body color) increases and decreases; and hence, design levels tend to diverge. In conclusion, the measurement of dominance on product design factors contributes to marketing managers and designers who are required to establish a strategy for products under the rapidly changing circumstances of market. This research aims to provide those managers and designers with a guide line for a successful development of new product to prepare for the dominant design from this empirical study.

  • PDF

Physiological and Biochemical Response of Blood on Low Temperature Stress in Sevenband Grouper, Epinephelus septemfasciatus (저수온 스트레스에 따른 능성어 (Epinephelus septemfasciatus) 혈액의 생리생화학적 반응)

  • Park, Jong Youn;Park, Jae Min;Hong, Chang Gi;Kim, Kyong Min;Cho, Jae Kwon
    • Korean Journal of Ichthyology
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted to investigate the physiological responses of sevenband grouper, Epinephelus septemfasciatus at low temperature condition in winter season. Water temperature was dropped from $12^{\circ}C$ to $5^{\circ}C$ by two different interval (interval I: $-1^{\circ}C/24h$ and interval II: $-1^{\circ}C/8h$). The experimental fishes were exposed for 9 days at each water temperature condition, and were observed survival rate. The blood sample was collected from fishes for analysis of cortisol, glucose, total protein (TP), and electrolytes ($Na^+$, $Cl^-$, $K^+$). Mortality of fish was not observed until $5^{\circ}C$. The mortality (12 individuals) began after 170 h and all fish were death after 174 h in interval I case, whereas the mortality (9 individuals) began after 72 h and all fish were death after 76 h in interval II case. Little different was observed in the physiological responses, but trend was similar between two intervals. The physiological metabolism of plasma cortisol and glucose were increased rapidly, and swimming ability and respiration response was faster at $7^{\circ}C$. This result means that the critical temperature of sevenband grouper was $7^{\circ}C$ at low water temperature condition.

C00rdinated Testing between transformer Tap Selection and Inverter Voilage Control in the PV Distributed Generation system (태양광 분산 발전 시스템의 계통연계용 변압기탭 선정과 인버터전압조정 협조시험)

  • Yoon, kap koo;CHO, SeongSoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1098-1099
    • /
    • 2015
  • ${\bullet}$ 시험대상: 영월태양광 4,990kW(998kW ${\times}$ 5호) ${\bullet}$ 13.07.31 연계기술검토의뢰 ${\bullet}$ 13.08.28 한전검토결과: 인근변전소 영월S/S(40MW) 초과로 10.8km 지점의 평창 D/L 평창간 347호 주진S/S에 다음의 보완대책과 연계 권고 ${\cdot}$ 문제점: 적정전압이탈 및 순시전압변동률 유지불가 ${\cdot}$ 연계기준만족을 위해 한전에서 제시한 보완대책 : 계통용량증설(설비보강), 연계용량 감소 및 전용선로 연계 ${\bullet}$ 14.01.09 분산형설치자의 용역사(에이스기술단)에서 송배전용전기설비 이용규정과 연계기준 만족을 위한 보완대책 제안 ${\cdot}$ 태양광발전시스템 인버터 자동전압(역률/무효전력) 조정기능 및 감시설비 구비 ${\cdot}$ 최적 공통연결점 선정: 분산형전원으로 부터 전기적으로 가장 가까운 영월D/L 영월S/S측에 개폐장치설치 하고 주진S/S 측으로 연계 ${\bullet}$ 14.01.29~06.19 한전(전력연구원)의 유효성 검토 ${\cdot}$ 보완대책 기술적 유효(실증시험 시행 후 시행공문 발송 예정) ${\bullet}$ 14.08.08 송배전용전기설비 이용규정 개정에 따른 협의 ${\cdot}$ 변압기 대당 20MW에서 25MW ${\cdot}$ 변전소 전체 60MW에서 75MW까지 허용 ${\cdot}$ 영월 S/S 측 문곡/영월 D/L 연계 공사 협의 ${\bullet}$ 14.10.04 사용전검사, 한전계통연계운전 시작 ${\bullet}$ 인버터 고정역률(99.9~100%) 운전 시험 ${\cdot}$ 14.11.21 22.9kV 계전기(SEL-751) 5대, 15분 간격 자료저장 ${\cdot}$ SEL-751/USB to RS232C/노트북 15분간격 측정(첨부) ${\bullet}$ 14.03.07 인버터 역률 95.0% 조정 15분간격 측정(첨부) ${\bullet}$ 변압기탭 선정과 인버터전압조정협조시험 계획 ${\cdot}$ 변압기탭을 현장에서 상하 1탭씩 변경 ${\cdot}$ 인버터역률을 인버터공급사에서 원격조정 ${\cdot}$ 22.9kV 보호계전기 SEL-751, 15분 간격 측정 ${\cdot}$ 인버터 370V 계전기 K-PAM DG3000/현장감시설비 연계 ${\cdot}$ 15분 간격 측정 저장 ${\cdot}$ 현장감시설비/인터넷 연결 원격측정(첨부예정)

  • PDF

Structural Analysis of Damping Hinge for Built-in Side-by-Side Refrigerator and Design Improvement of Bracket Pin to Reduce Stress Concentration (빌트인 양문형 냉장고 댐핑힌지의 구조해석 및 브래킷핀의 응력집중 저감을 위한 설계개선)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.373-379
    • /
    • 2020
  • This study performed stress and fatigue life analysis of the damping hinge of a built-in side-by-side refrigerator that occurs when the door is opened to the maximum angle. An analysis of the initial design showed that stress concentration occurred at the corner between the cylinder and upper disk of the bracket pin, and the maximum stress exceeded the yield strength. The maximum stress location and the calculated fatigue life were consistent with the door opening-and-closing endurance test results for a prototype. Three cases of design improvement for the bracket pin were derived with the aim of reducing the stress concentration that appeared in the initial design. An analysis of the cases showed that inserting a fillet between the disk and the cylinder of the bracket pin reduced the stress and increased the fatigue life. Moreover, changing the disk into two steps was more favorable. In conclusion, the best design improvement was the case that the disk was changed to two steps and the fillet with a large radius was inserted. In that case, the stress was the smallest and the fatigue life was infinite.

Atmosphere and Green Pepper Quality Influenced by Active Air Flushing in Fresh Produce Container Controlled in Real-time $O_2$ Concentration (실시간 $O_2$ 농도 제어 풋고추 용기에서 능동기체치환 시스템이 기체조성과 품질보존에 미치는 효과)

  • Jo, Yun Hee;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.2
    • /
    • pp.29-33
    • /
    • 2014
  • Active air flushing mini-pumps were installed in a rigid polypropylene container ($32cm{\time}23cm{\time}18cm$) containing 900 g of fresh green peppers for effectively controlling its $O_2$ concentration on real time basis to preserve the product quality. The performance of the constructed system was compared to that of the modified atmosphere (MA) container system with gas diffusion tube controlled in close/open cycles responding to real time $O_2$ concentration at 10 and $20^{\circ}C$. In the control logic, the $O_2$ concentration was programmed to be located exactly at 13% or stay in the range of 13-15%. The active air flushing system could control the $O_2$ concentration in the desired level or range at both temperatures, while the passive diffusion system could work only under the low temperature condition of $10^{\circ}C$. At higher temperature of $20^{\circ}C$, the passive diffusion system could not manage the produce respiration increased more highly than the gas transfer through the diffusion tube, resulting in too low $O_2$ concentration and too high $CO_2$ concentration which would be injurious to the green pepper. When tested at $20^{\circ}C$, the MA container system could preserve the green pepper better than the perforated air package in terms of weight loss, ascorbic acid and chlorophyll contents and firmness.

  • PDF

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

Stomatal and Photosynthetic Responses of Betula Species Exposed to Ozone (오존에 노출된 자작나무류의 기공개폐와 광합성 반응)

  • 이재천;김장수;한심희;김판기
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • This study was conducted to determine the relationship of stomatal responses, photosynthesis, and intercellular $CO_2$ concentration( $C_{i}$) of Betula Species to ozone exposure. Five Betula Species(B. costata, B. davurica, B. schmidtii, B. platyphylla var, iaponica and B, ermani) were grown in the greenhouse. One-year-old potted seedlings of the five Betula Species were exposed to ozone(100 pub) for 8 hours da $y^{-1}$ for 5 weeks in a fumigation chamber. Net photosynthesis was significantly different among species and treatments from early in the period of the fumigation. Stomatal conductance and transpiration rate differences among species and treatments became significant after three weeks of fumigation. $C_{i}$ was significantly different only among treatments; $C_{i}$ of four species, except for B. davurica, was higher than that of control plants. Carboxylation efficiency and photo-respiration rate were significantly different among species or treatments; carboxylation efficiency and photo-respiration rate of the five Betula Species were decreased by ozone treatment. It was concluded that stomatal closure of Betula Species may be the result of the reduction of photosynthesis and rubisco activity and the resulting increase of $C_{i}$. The higher $C_{i}$ likely resulted from reduced photosynthesis because of physiological processes.ocesses.

Left Atrial Myxoma Associated with Mitral Regurgitation and Coronary Artery Disease (승모판막폐쇄부전 및 관상동맥질환과 동반된 좌심방 점액종)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Sae;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Park, Yoon-Ock;Moon, Hyun-Soo;Paik, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.862-865
    • /
    • 2003
  • Obstructive intracardiac lesions, like mitral stenosis or insufficiency (MR), by myxomas of the left atrium have been commonly reported, but the attenuation of MR by myxoma combined with coronary artery disease is very rare. We report a 70-year-old female patient whose left atrial myxoma had attenuated moderate MR to mild MR and required mitral valve surgery after removal of the myxoma. She also had coronary artery disease, severe pulmonary hypertension and moderate tricuspid regurgitation due to the mitral valve lesions obstructed by myxoma. The patient underwent removal of myxoma, mitral and tricuspid valve reconstructions, and coronary artery bypass grafting. She was discharged at the postoperative 14 day without any problems.

Sliding Wear Properties of Graphite as Sealing Materials for Cut off Hot Gas (고온차단 기밀용 그라파이트의 고온 미끄럼마모 특성 평가)

  • Kim, YeonWook;Kim, JaeHoon;Yang, HoYeong;Park, SungHan;Lee, HwanKyu;Kim, BumKeun;Lee, SeungBum;Kwak, JaeSu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1349-1354
    • /
    • 2013
  • Sealing structure to prevent flowing hot gas into the driving device, located between the driving shaft and the liner of On-Off valve for controlling the hot gas flow path was studied. Wear occurs due to the constant movement of the driving shaft controlled by actuator on graphite as the sealing material. In this paper, the dynamic wear behavior in high temperature of graphite(HK-6) to be used as sealing material was evaluated. Reciprocating wear test was carried out for the graphite(HK-6) to the relative motion between shaft materials(W-25Re). The results of friction coefficient and specific wear rate according to contact load, sliding speed at room temperature and $485^{\circ}C$ considering the actual operating environment were evaluated. Through the SEM analysis of the worn surface, third body as lubricant films were observed and lubricant effect of third body was considered.

Numerical analysis for deformation characteristics under the freezing and bursting of Al pipe (알루미늄 관의 동파 거동특성에 관한 수치적 연구)

  • Choi, Seung-Hyun;Lee, Dong-Won;Ko, Young-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4763-4768
    • /
    • 2014
  • Recently, aluminum pipes have been used instead of steel pipes for open and shut machines in vinyl housing because of its corrosion-resistance and light weight. In particular, the light weight is very useful for fitting and removal by human resources. On the other hand, an aluminum pipe is weak in winter because aluminum has a larger thermal expansion coefficient than steel. This study examined the freezing and bursting of aluminum pipes by numerical analysis. The mechanical-thermal deformation characteristics were analyzed under the condition of ice volumetric expansion in aluminum pipes reaching 50%. From numerical analysis, large stresses above the yield stress occurred in aluminum pipe after ice expanded in the net diameter immediately. In addition, the freezing and bursting of aluminum pipes was predicted around an ice volumetric expansion of 6 - 7% because the thickness of the aluminum pipe reached an aluminum elongation ratio of 17%. Therefore, it is recommended that aluminum pipes be sealed perfectly to prevent water flow in the pipe. These results suggest that it is very difficult to prevent freezing and bursting of aluminum pipes by water freezing in the pipe.