Gas flow pattern through a long round tube of a gas fueling system (I) (기체연료주입계의 긴 원형도관에서 기체 흐름의 유형)

  • IN, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.465-474
    • /
    • 2006
  • A gas fueling system composed of a gas reservoir, an on-off valve, and a gas transferring tube, which is the simplest construction for the pre-programmed gas puffing, was simulated by numerically solving the time-dependent one-dimensional gas flow equation. The purpose of the simulation is to establish the relationship between the gas flow pattern (the elapsed time to the maximum flow, the maximum flow rate, the gas pulse duration) and the system parameters (the filling pressure and the volume of the gas reservoir, and the length and the diameter of the gas transferring tube).

The Comparative Study on Safety Factors at Elevator Management System Operation (승강기 관리시스템 운영 시 안전요소에 관한 비교연구)

  • Park, Joo-Bong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.159-162
    • /
    • 2014
  • Recently, from 2008 to 2012, there are many of elevator safety patents from patent office survey. In this paper, we analyzed the elevator safety patent from 2009 to 2013, found out safety factor is safety control, emergency stop equipment and door opening equipment. Through reliability statistics, we defined the most important things for safety elevator factor is this three things, studied the reason about many patents. Finally, we propose the Kinect Scada elevator system for prevention safety accident.

System Design and Fundamental Experiment for Thrust Control of $GO_2$/PE Hybrid Rocket ($GO_2$/PE 하이브리드 로켓의 추력제어를 위한 시스템 설계 및 기초실험)

  • Lee, Yong-Wu;Kang, Wan-Kyu;Huh, Hwan-Il
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.1
    • /
    • pp.40-47
    • /
    • 2010
  • In this study, basic research on the thrust control by controling oxidizer mass flow rate of a $GO_2$/PE hybrid rocket is presented. For this purpose, hybrid rocket system including oxidizer flow control system and data acquisition system was developed. To control oxidizer mass flow rate, we used needle valve with stepping motor which was controled by LabVIEW program. During the fundamental experiments, this system managed to follow the pre-programmed (20 N - 10 N - 20 N - 0 N) thrust level.

독립전원으로 구동되는 변압기 일차측 개폐 회로를 적용한 대기전력 저감 장치에 관한 연구

  • Choe, Dae-Seop;Jeong, Chan-Ung;Park, Seong-Tae;Hwang, Min-Yeong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.434-435
    • /
    • 2008
  • 최근 국내 IT 산업의 발달에 따른 디지털화에 따라서 대기전력에 의해서 소비되는 전력소모량은 일반 가정용 전원을 기준으로 할 때 전체 사용량의 11%에 육박하는 수준까지 나타나고 있으며, 이는 다른 선진국에 비해서도 상당히 높은 수준으로 미국의 5% 수준의 2배가 넘는 수치이다. 전기, 전자제품의 디지털화 의 추세는 일반가구 및 산업시설에 공급되는 공급전압에 비해서 상당히 낮은 전압으로 제품이 동작하게 되며, 이러한 전압변환은 제품에 내장된 변압기에 의해서 수행되는데, 변압기는 전기, 전자제품이 구동하지 않는 경우에도 일차측에 인가된 전압에 의해서 발생되는 대기전력 소비량에 의해서 일정 크기의 전력소모가 지속적으로 이루어지고 있다. 본 연구에서는 대기전력에 대해서 가전제품의 대기상태를 유지하기 위한 상태에서 소모되는 전력량 및 변압기의 1차측에서 유도되나 2차측에서 전력에너지로 변화되지 못하고 소실되는 손실을 모두 포함하는 것으로 정의를 내리고, 해당 적용 제품의 비구동상태에서 독립된 전원으로 구동되어 변압기의 1차 측을 완전히 개방하여 1차 측 전압인가에서 발생되는 손실까지 모두 줄일 수 있는 회로에 대한 기술적인 구성과 적용가능성에 대하여 연구하였다.

  • PDF

Flashover Voltage of 800kV Class Composite Hollow Insulator for $SF_6$ Gas Insulated Switchgear (GIS) (800kV $SF_6$ 가스절연 개폐장치용 (GIS) 복합절연애자 (Composite Hollow Insulator)의 표면오손시 내전압특성)

  • Lee, C.R.;Yoon, J.H.;Choi, B.H.;Yoon, C.Y.;Ko, K.S.;Ban, S.G.;Huh, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1449-1451
    • /
    • 2002
  • A developed 800kV class composite hollow insulator for $SF_6$ Gas Insulated Switchgear (GIS) was tested as to insulation with their surfaces contaminated. The wet power frequency withstand voltage of the silicone rubber housing was about 135kV at an equivalent salt deposite density of $5kg/m^2$, to sufficiently satisfy the required performance. According to IEC 60507, the salt fog withstand voltage was measured at 565kV, and the highest measured leakage current was below 0.2mA. Therefore, it was clarified that the composite hollow insulator has sufficient insulation performance even when it is contaminated on the surface.

  • PDF

Analysis of the Evacuation Safety of Indoor Stadiums with Automatic Opening/Closing Exit Installations (출입문용 자동개폐장치를 설치한 실내체육관의 피난안전성 분석)

  • An, Jae-Chun;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.15-21
    • /
    • 2020
  • This study analyzed the evacuation time in indoor stadiums when exits that automatically open/close when the fire sensor is triggered are installed as a means to improve the problem of closing certain exits. Firstly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 529.8 seconds when the automatic opening/closing exits are broken and employees are not present. Secondly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 445 seconds when the automatic opening/closing exits with 750mm width are working but employees are not present. Lastly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all spectators was 337 seconds when the automatic opening/closing exits with 1,500mm width are working and employees are present. As a result, it was revealed that the evacuation time is shortened when the automatic opening/closing exits are working. Additional comparative studies with actual simulations of people evacuating an indoor stadium and firefighting simulations considering smoke flow are necessary.

A Study on the Development of a Remote Monitoring Equipment for Ground Fault Current by Lightning Strike (낙뢰에 의한 지락전류 원격 감시장치에 관한 연구)

  • Pyo, Se Young;Kim, Tag Yong;Kim, Kee Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.783-788
    • /
    • 2020
  • Surges generated by direct strike or induction of lightning, frequent opening and closing of power system breakers, etc. cause excessive overvoltage, which can interfere with normal operation of transformers, circuit breakers, and power equipment. In order to prevent such phenomena, this study goes further from the method of establishing countermeasures by installing lightning arresters on power equipment or lines in parallel, and furthermore, remotely checking the condition of the lightning arrester and preparing immediate countermeasures when an event occurs. The purpose of the study is to prevent damage in advance.

Effect of a Diaphragm Opening Process on Flow Condition in Shock Tunnel (격막 파열과 충격파 터널 시험 시간에 대한 수치 연구)

  • Kim, Seihwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.6
    • /
    • pp.20-28
    • /
    • 2021
  • High enthalpy test facilities, such as a shock tunnel, are to be operated at the specific pressure ratio according to the desired test condition. A metallic diaphragm is machined or a forced rupture device is used to open it at a specific pressure ratio. The diaphragm opening procedure takes several hundred microseconds including rupture and deformation. This process is expected to affect the test conditions. In this study, numerical simulation was performed for different materials, thicknesses, and opening ratios. And the characteristics of shock wave generation and the stagnation condition in the tube are investigated. Results show that the final opening ratio and rupturing procedure directly affect the speed of a shock wave, stagnation pressure, and test time.

Analysis of Train Delay in Daejeon Metro (대전도시철도의 열차 지연운행 분석연구)

  • Kwon, Young-Seok;Lee, Jin-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • This study investigated the causes and problems of train operation impediments through the statistics analysis of 8 years'internal data of Daejeon Metropolitan Express Transit. By evaluating the risks regarding the system, equipment, and parts of high risk group, this study measured the Risk Index Severity, and applied the $5{\times}5$ Risk Assessment Matrix which is a method of risk management to calculate the scale of risk to analyze the safety level and allowance range. As a result, the car sector, the most serious risk, followed by machinery and equipment sector showed that the inherent risk. In particular, the door broken and the door rail signaling and control devices due to defects of the vehicle is high, but also the severity, and frequency are showing very frequent additional potential accidents. PSD also had defects in the machinery sector appeared to be the most dangerous of the PSD poor safety gates, it was found that the glass also involve the risk of mishandling and breakage of the PSD. This study intended to contribute to the transportation benefits through the safety and stable operation of Metropolitan Express Transit.

Flow Characteristics in the Downstream Region of a Butterfly Valve with Various Disk Opening Angle (디스크 회전각에 따른 버터플라이 밸브 하류에서의 유동특성)

  • Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.267-272
    • /
    • 2006
  • Butterfly valves have been used for shut-off and throttling-control application in many industrial fields. Recently, they are frequently used for cooling water, oil system and ballast piping system of many larger vessels. They are especially suited for flow throttling control of heat exchangers in engine room. Measurement by the PIV(Particle Image Velocimetry) was conducted to investigate the flow characteristics of butterfly valve inserted within circular pipe. Flow behaviors such as instantaneous and time-mean velocity vectors are investigated. Furthermore, to reveal systematic performance of the butterfly valve, wall pressure was measured at 6 points along the pipe by digital manometer. As the valve position moves to the closed side, flow separation increases and persists its tendency downstream until smoothly uniform flow developed. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 60 degrees.

  • PDF