• 제목/요약/키워드: 개별 공조시스템

검색결과 26건 처리시간 0.024초

개별환경제어시스템의 열 및 유동 해석 (Air Flow and Heat Transfer Analysis of Personal Environment Module System)

  • 조은준;서태범;박영철
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.252-261
    • /
    • 2001
  • Room air flow and temperature distribution was numerically investigated where a PAC(personal air conditioning) system was installed. The calculated results were compared with those from experiments. The effects of the important operation parameters such as the air flow rate, velocity, and temperature at the diffuser on the thermal performance of the system were studied. The possibility of energy saving using the PAC system was verified from the results, It was shown that the warm air from the diffuser could not spread over the whole task area if the inlet temperature was too high.

  • PDF

열환경 제시를 위한 공조 시스템의 개발 (Air-conditioning System for Thermal Presentation)

  • 김영일;장영수;정구헌;이기섭
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 춘계학술발표 논문집
    • /
    • pp.275-280
    • /
    • 1998
  • 인간의 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져 있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들과 인간의 감성과는 밀접한 관련을 지닌다. 열환경과 관련된 인간의 감성을 측정, 평가하기 위해서는 주위의 열환경이 정밀하게 제어되는 공간에서 작업이 이루어져야 한다. 실내 공간의 열환경을 임의로 제어하기 위해서는 급기되는 공기의 조건과 벽체의 온도가 정밀하게 제어되어야 한다. 공기와 벽체 조건은 가열, 냉각, 가습 또는 제습에 의하여 정밀하게 제어되며 이를 실현하기 위하여 공조 시스템은 일반적인 시스템과는 달리 특수한 조건이 요구된다. 공조 시스템의 각 구성요소가 컴퓨터에 의해 개별적으로 제어될 수 있어야 하며 특수 조건에 따른 유연성이 뛰어나야 한다. 본 연구에서는 열환결 제시에 적합한 공조 시스템을 개발한다.

  • PDF

개별공조에 의한 CR에서의 Heat Gain과 재실자 온열성 연구 (Occupant's Thermal Comfort and Heat Gains in CR by PEM)

  • 김원태
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 추계학술대회 논문집
    • /
    • pp.13-18
    • /
    • 1999
  • 기존의 공조방식 및 본 연구에서 제안한 개별환경제어시스템(PEM)으로부터 열유체 유동 헤석용 PHOENICS 프로그램을 이용하여 3차원 시뮬레이션을 수행하여 재실자가 거주하고 있는 CR(컴퓨터실)에서의 Heat Gain과 재실자 온열성 특성을 감성공학적 측면에서 분석하였다. 본 연구로부터 바닥으로부터 공기를 유입하여 천정으로 유출하는 바닥취출공조방식이 실내 환경 개선에 유리하고 diffuser만을 통하여 공기가 유입되어 천정과 바닥으로 공기가 유출되는 PEM 방식은 열적 냉각 성능은 좋으나 PC와 재실자 주변에 강력한 재순환 유동이 발생되어 실내 환경의 쾌적성 측면에서는 불리하나 PEM과 TAM방식의 결합이 감성공학적 온열특성 분포로부터 CR실의 재실자 주변 온도 분포에 최적임을 알 수 있다.

  • PDF

개별공조시스템을 위한 전기히터의 PID 제어 (A PID Control of Electric Heater for PEM)

  • 장영준;박영칠;정광섭;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.59-65
    • /
    • 2001
  • The work presented here is an implementation of PID control to achieve a required supply air temperature in PEM(Personal environment module). In PEM, the air is heated to the required temperature while it flows through the supply duct, without any mixing chamber. This makes the control of air temperature in PEM difficult. Linear dynamic model of heat transfer in PEM is first obtained. Then P, PD and PID type control systems, to provide the rapid response without overshoot and saturation, are designed and implemented experimentally. Data obtained shows that the control system satisfied the design criteria and works properly in controlling the supply air temperature.

  • PDF

개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS))

  • 최익순;정광섭;박영철;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가 (Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System)

  • 김세환;박종일
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

LCC 기법을 이용한 신기술 냉 $\cdot$ 난방 공조설비 시스템의 경제성 분석에 관한 사례연구 (A Case Study on the Economic Analysis for an Advanced Technology-Based HYAC System Using LCC Technique)

  • 김용수;황성수
    • 한국건설관리학회논문집
    • /
    • 제6권2호
    • /
    • pp.129-138
    • /
    • 2005
  • 본 연구는 LCC 기법을 이용한 냉 $\cdot$ 난방 공조설비 시스템에 대하여 사업 실행전 LCC와 사업 실행후 LCC를 예측, 성과측정 및 경제성 평가를 목적으로 진행되었다. 이를 위해 신기술 냉 $\cdot$난방 공조설비 시스템의 Life Cycle동안의 비용자료를 실적자료와 견적자료, 인터뷰등의 방법으로 조사 $\cdot$ 분석하였다. 또한 분석기간 15년 동안의 사업 실행전 $\cdot$ 후의 LCC를 예측하여 성과측정 및 경제성 평가를 실시하였다. 이와 같은 과정을 통해 수행된 본 연구의 결과는 다음과 같다: 1)일체형 개별냉 $\cdot$난방공조설비의 설치로 인해 할인비용시 $21.6\%$의 경제성이 있는 것으로 분석되었다. 3)성과측정은 투자대비 회수배율로서 할인비용시 회수배율은 신축의 경우 4.8배, 리모델링의 경우 14.4배의 경제성이 있는 것으로 분석되었다.

WORK BARGE 선의 냉동.공조 SYSTEM (HVAC & Refrigeration System for Work Barge Vessel)

  • 남임우;정재천;김봉제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.583-590
    • /
    • 2008
  • 최근 작업자 숙소 및 이송용 외에 작업용으로 사용 가능한 Barge선의 일종인 Accommodation Work Barge 선의 건조량이 증가 추세인 바 현재 중국에서 건조 중인 해당 선박의 HVAC & Refrigeration system에 대하여 정리하였다. 본 시스템은 R404A Direct expansion 냉각방식 (직접팽창방식)이 적용되었으며 HVAC system 중 Air conditioning 부분에 대해서는 선박의 각 Deck 기준으로 Zoning 하여 개별적인 Air handling unit와 Condensing unit를 구성하였으며 (각 unit의 용량은 필요용량의 100%), 냉동 창고의 Refrigeration system은 해당 격실 (육고, 어고, 야채고)에 각각 Unit cooler를 설치하고, Condensing unit를 기계실에 설치하였다. 장비는 전체 용량 100%에 대하여 항시 운전하는 100% 용량의 장비와 비상시에 운전하는 100% 용량의 예비 장비로 구성된다. 냉동 창고에 인접한 Dry provision store는 냉동 창고와는 별개로 중앙 공조기로부터의 냉각 공기를 이용하여 Spot cooling하였다. 본 System의 구성에 대한 장점 및 단점은 아래와 같다. 1. Air conditioning system이 각 Zone에 대하여 구성되므로 각 Zone에 대하여 제어가 가능하다. 2. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 냉매 배관의 길이가 짧다. 3. Air con. 실에 Air handling unit와 Condensing unit가 설치되므로 실내의 Maintenance space 상에 여유가 없다.

  • PDF