• Title/Summary/Keyword: 개도율

Search Result 26, Processing Time 0.026 seconds

Analysis of Elastic Wave Based Leakage Detection Technology Using Accelerometers (가속도계를 이용한 탄성파 기반 누수탐지 기술 분석)

  • Choi, Kwangmook;Lee, Hohyun;Shin, Gangwook;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1231-1240
    • /
    • 2020
  • Water pipes are laid on the ground, making it impossible to visually detect leaks due to aging of pipes, and technology to detect leaks in pipes is mainly used to detect leaks in pipes by detecting leaks. In this paper, two accelerometers were attached to both ends of the constant water piping to calculate the time difference between the acquired data to detect leakage points. The leak test of piping was performed by installing valves at 4.3m, 8.6m, and 12.9m points on piping 17.2m, and changing the development rate of valves to 30% and 70%. Leakage can be detected for pressure drop in piping, which is 30% and 70% open valve. It is very important to detect leakage in the early stage, and it is judged that detection of the initial leak point from the algorithm applied in this paper will be possible.

Reproducing water flow using 3D game engine (3D게임엔진을 이용한 물 흐름 재현)

  • Woochul Kang;Eun-kyung Jang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.432-432
    • /
    • 2023
  • 한국건설기술연구원(Korea Institute of Civil Engineering and Building Technology, KICT)의 안동하천연구센터(Andong River Experiment Center, REC)는 다양한 하천 관련 실규모 실험을 수행하기 위해 3개의 수로를 보유하고 있다. 본 연구의 주목적인 실증 실험 계측 결과를 기반으로 3D 게임엔진을 이용하여 물 흐름을 재현하기 위해 A1 수로를 대상구간으로 설정하였다. 실증 실험의 경우 2개의 수문 개도율 조건에서 ADV와 ADCP를 활용하여 계측된 유량 및 유속 결과들을 비교하였으며, 추가적으로 영상 데이터로 부터 표면유속(LS-PIV)을 산정하였다. 3D 게임 엔진은 렌더링 엔진, 물리 엔진, 오디오 엔진, UI 시스템, 게임플레이 프레임워크 등이 잘 융합된 소스코드들과 개발자들이 이용하기 쉬운 방식으로 변환된 툴(tool)로 제공하여 현실 세계를 가상 세계에 시각화하여 구현하는데 큰 장점을 가지고 있다. 또한 기존의 흐름 재현이 가능한 수리/수문 모델링의 경우 특정한 목적으로만 이용가능하고 연산에 소용되는 시간 때문에 실시간 흐름재현이 어렵지만, 3D 게임엔진을 이용하는 경우 다양한 목적과 여러 분야와의 고려가 동시에 가능하며 연산의 단순화를 통해 실시간 흐름 재현이 가능하다는 장점이 있다. 본 연구에서는 언리얼 엔진의 Niagara Fluids와 Fluid flux 툴들을 활용하여 하천실증실험 시설 일부 구간에 대해 물 흐름을 재현하였다. 먼저 하천실험실증시설을 드론과 RTK-GPS를 이용하여 촬영된 결과를 정합하여 3D 게임엔진 기반 흐름 재현을 위한 지형 기초 자료를 구축하였다. 지형 계측 결과를 기반으로 A1 수로 전체 구간을 대상구간으로 설정한 이후 수문 조절을 통해 흐름 조건을 제어할 수 있도록 제작하였으며, 실제 흐름에 대한 계측 결과를 기반으로 재현된 흐름을 대상으로 material 값의 조정(방향 X, Y값을 RGB값으로 변환한 뒤 벡터 길이 값으로 환산)을 통해 0~100 사이 값을 이용하여 유속을 표현하였다. 최근 가상공간 (i.e. 디지털트윈) 관련 시장 성장이 매우 빠르고 다양한 사업에서 해당 기술의 수요가 증가하고 있으며, 본 연구를 통해 물 흐름의 디지털 트윈화를 위한 수단으로서 3D 게임 엔진의 활용 가능성을 확인하였다. 다만 실제 하천의 적용과 하천관리를 위한 실용화를 위해서는 추가적인 연구와 분석이 이루어져야 할 것이다.

  • PDF

Features and Cost Reduction Effect of High Pressure LNG Pipeline Network (고압 LNG 배관망의 특성 및 비용절감 효과)

  • Kim, Ho-Yeon;Hong, Young-Soo;Noh, Joo-Young;Eom, Yun-Seong;Kim, Cheol-Man
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.139-144
    • /
    • 2008
  • Recently due to march as the high oil price, It is necessary for Korea to grope a plan, which is to increase the energy efficiency of existing facilities as well as to develop overseas gas and oil resources. With this point, this work carried out to approach the high pressure LNG pipeline network of Inchon receiving terminal with Newton method as corrective flowrate. We found that the high pressure network mainly depends on FCVs(Flow Control Valves). The high pressure pump showed the maximum efficiency at the FCVs of 50% opening and could discharge LNG only above the LNG head of 1,500m from a system curve obtained. The operating cost of pumps was estimated from their operating points. We compared the operating cost under normal operation with the operating cost under maximum efficiency. Especially, we obtained the day savings of a year as wells as the hour savings of a day. From the results, the high pressure network win be able to reduce the operating cost of 138 million wons in a year. This means that a pump can reduce the operating cost of 9,823 thousands won. Consequently, this work could find the operating features of the pumps under the complicated high pressure LNG network and the savings effect of the pump operating cost. Also, the results will be able to macroscopically contribute the heightening of national energy competitiveness as well as to microscopically contribute the future effective operation of LNG receiving terminal.

Optimal Ccontrol Strategy of Cooling System for Polymer Electrolyte Membrane Fuel Cell using Hardware-In-the-Loop Simulation (Hardware-In-the-Loop Simulation을 이용한 고분자 전해질 연료전지 냉각시스템 최적 제어기법 연구)

  • Choi, Eunyeong;Ji, Hyunjin
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.113-121
    • /
    • 2016
  • Polymer electrolyte membrane fuel cell(PEMFC) requires cooling system to maintain the proper operating temperature(about $65^{\circ}C{\sim}75^{\circ}C$) because the efficiency and power are affected by operating temperature. In order to retain the operating temperature of PEMFC, cooling system and coolant control logic are needed. Hardware-in-the-loop simulation(HILS) is one of effective methods to study and evaluate control algorithm. In this paper, the HILS system was designed to study the coolant control algorithm. The models of HILS system consisted of PEMFC, heat exchanger, and external environment associated with temperature. The hardwares in HILS system are 3-way valves, pumps, and a heat exchanger. The priority control and the control target temperature were investigated to improve the control performance using HILS. The 3-way valve in $1^{st}$ cooling circuit was selected as priority control target. The under limit value of $2^{nd}$ 3-way valve set as a function of PEMFC power and $2^{nd}$ circuit coolant temperature to correct temperature control performance. As a result, the temperature of PEMFC is stably controlled.

Evaluation of Effect of Low Opening Operation on Increasing Wear of Bearing Bushings of Guide Vanes used in Hydropower Plants (수력발전소 가이드 베인 저개도율 운전에 따른 가이드 베인 베어링 부슁의 마모 가속효과 평가)

  • Kim, Jong-Sung;Kim, Se-Na
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1267-1274
    • /
    • 2012
  • A guide vane plays a key role in controlling the flow rate of water supplied to the turbine of a hydropower plant. It has been reported that guide vane bearing bushings are subjected to considerable wear, which requires them to be maintained. An ancillary service such as frequency control and black start causes cyclic low opening operation of the guide vanes. It is empirically well known that such operation increases the wear rate of the guide vane bearing bushing. In this study, the effect of low opening operation on the increasing wear of the guide vane bearing bushing is quantitatively assessed via finite element flow analysis, finite element stress analysis, and relative wear evaluation. As a result of the assessment, it is identified that the pressure applied on the guide vane surface increases and the contact length between the outer surface of the guide vane stem and the inner surface of the bearing bushing decreases with a decrease in the opening of the guide vane. In addition, low opening of the guide vanes results in an increase in the relative wear owing to the generation of high contact pressure on the bearing bushing surfaces.

Simulating inundation depth and area in paddy fields considering back flows (역류를 고려한 논 침수 모의 해석 방법)

  • Noh, Jaekyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.31-31
    • /
    • 2021
  • 2020년 8월 7일부터 8월 8일까지 호우는 용담댐, 섬진강댐, 합천댐 등 하류 유역의 농경지에 막대한 침수피해를 일으켰다. 특히 논의 인삼재배 지역은 피해가 컸다. 지역에 따라 내수유입, 제방월류, 배수로 역류, 용수로 유입 등 유입량 과다의 침수 현상을 나타냈다. 여기서 이들 다양한 유입량 요소를 고려하여 제내지의 침수심, 침수면적을 모의할 수 있는 물수지 모형을 구축하였고, 하천 수위관측자료가 있는 금산 지역에 적용한 예를 제시하고자 한다. 물수지 모형의 구성은 저류량은 유입량과 방류량으로 구성되며, 유입량은 자체유입, 용수로 유입, 배수로 역류, 제방월류 등으로 구성하였고, 용수로, 배수로의 수문은 원형, 구형 두 가지로 개도에 따라 오리피스 공식을 적용하는 것으로, 제방월류는 여수로 공식의 계수를 조정 적용하는 것으로 하였다. 제내지 내용적은 1:1,000 지형도에서 DEM 자료를 추출하여 생성하였고, 자체유입량은 ONE 모형에 의해 10분 단위로 모의하는 것으로 하였다. 모형 적용 결과는 제원리 제내지 경우이며, 8월 6일 부터 8월 10일 까지 유역면적 322.1ha인 제내지의 10분 간격 물수지 분석 결과, 현장의 침수흔적 조사의 최고수위가 일치하도록 배수문과 배수통관의 방류시 개도율을 조정하며 분석하였다. 이 상태의 침수위 모의 분석결과는 월류고 EL.133.86 m, 월류길이 29m로 나타났다. 10분 최대 강우량 9mm, 1시간 최대 강우량 19mm, 총 강우량 225mm(724,725m3)였고, 10분 최대 유입량 5.619m3/s(3,371m3), 평균 1.264m3/s(758m3), 총545,933m3였다. 용수로 유입은 없었고, 배수문 역류 유입량은 13시간 50분 동안, 10분 최대 6,836m3, 총 28.26만m3였고, 제방월류 유입량은 9시간 30분 동안, 10분 최대 7,212m3, 총 33.15만m3였고, 배수문 방류량은 3일 20시간 20분 동안, 10분 최대 19,932m3, 총 116.13만m3였다. 하천수위는 최고 EL.134.45m, 최소 EL.128.51m, 평균 EL.130.69m였고, 내수위는 최고 EL.134.05m, 최소 EL.129.00m, 평균 EL.131.02m였다. 최고 침수위 EL.134.05m일 때 DEM으로부터 침수면적은 38.88ha로 분석되었다. 내수 유입에 의한 침수면적 19.54ha를 빼면 10.71ha가 배수문과 제방월류를 통해 유입된 수량으로 침수된 것으로 분석되었다.

  • PDF