• 제목/요약/키워드: 개구부 형태

Search Result 72, Processing Time 0.026 seconds

A Experimental Study on Window Glass Breakage in Compartment Fires (구획 화재시 창유리 파괴 현상에 관한 실험적 연구)

  • 이수경;김종훈;최종운;이정훈
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.21-30
    • /
    • 1998
  • This is a study on the relation of window glass breaking time, shape, and vent condition in a compartment fire through the experiment. We recognize the phenomenon that window glass breakage in a compartment fire be arose from the thermal stresses due to the temperature temperature difference was 233.4$^{\circ}C$ for test 1-3, 138$^{\circ}C$ for text 2-1, 83.6$^{\circ}C$ for test 2-2. The interior test 2-2, 400.9$^{\circ}C$ for test 2-3. so if the flame didn't reach at the surface of window glass, the breakage of glass occure at 40$0^{\circ}C$~50$0^{\circ}C$. when the fire size reached to 1541.14kW, the window might be broken by thermal stress. But window glass was not collapsed.

  • PDF

Application of LRBs for Reduction of Wind-Induced Responses of Coupled Shear Wall Structures (전단벽 구조물의 풍응답 저감을 위한 LRB의 적용)

  • Park, Yong-Koo;Kim, Hyun-Su;Ko, Hyun;Kim, Min-Gyun;Lee, Dong-Guen
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.47-56
    • /
    • 2011
  • In general, shear walls are employed as lateral resistance system. Most of shear wall structures require openings in shear walls and thus shear walls are linked by floor slabs or coupling beams resulting in the coupled shear wall structures. In this study, an LRB (lead rubber bearing) was introduced in the middle of the coupling beam of the coupled shear wall structures and the wind-induced response reduction effect of this system was investigated. In order to evaluate the control performance of the proposed method, 20- and 30-story building structures were used as example structures and boundary nonlinear time history analyses have been performed using artificial wind excitation. Japanese vibration evaluation criteria was employed to evaluate whether the proposed system could improve the serviceability of the tall coupled shear wall structures under wind excitation. Based on analytical results, it has been shown that the proposed method that connects shear walls with LRBs can improve the wind-induced response control effect.

Design of the Parabolic Reflector Antenna with Bended Elliptical Conductor Plate Feed (절곡된 타원형 도체평판 급전부를 갖는 포물선 반사판 안테나 설계)

  • Kim, Byung-Mun;Yun, Li-Ho;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.989-996
    • /
    • 2017
  • The proposed directional pencil beam antenna consists of a waveguide feeder with bended elliptical conductor plate feed and a parabolic curved reflector. Two rectangular apertures located at the broad wall near the end of the feed waveguide inserted from behind the reflector are located at the focus of the reflector and emit electromagnetic energy with bended elliptical conductor plate. This plate is designed to reflect electromagnetic energy primarily and to face the main reflector. The two rectangular apertures located at the waveguide end have inwardly protruding tabs for impedance matching of the antenna system, the shape of the tabs is a truncated oval. The proposed parabolic reflector antenna has a diameter of 400 mm and a focal length of 134.23 mm. The antenna gain is 33.68 dBi at the center frequency of 16.5 GHz, the beam width is $3.3^{\circ}$ and the reflection loss is -15 dB. Using the HFSS-IE, simulation results are performed to validate the proposed antennas.

Characteristic of Wave Diffraction and Reflection for Irregular Waves in SWASH Model Around Small Port Structures (소규모 항만 구조물 주변에서 불규칙파에 대한 SWASH 모형의 반사 및 회절)

  • Kwon, Kyong Hwan;Park, Chang Wook;Park, Il Heum;Kim, Jong Hoon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.468-477
    • /
    • 2019
  • The numerical model of Boussinesq approximation, which is mainly used for evaluating the port calmness due to the irregular waves, has a limit of applicability of lattice size in ports such as marinas with narrow port openings of around 30m. The SWASH model controls the partial reflection according to the depth, porosity coefficient and structure size when applying the reflected wave incident on the structure and terrain. In this study, the partial reflection evaluation at the front of the structure according to the bottom shape and the shape of the structure are examined. In order to evaluate the reproducibility of the model due to the diffraction waves entering the term, the area of incidence at right angles and inclination of the structure is constructed and compared with the diffraction theory suggested by Goda et al. (1978). The experimental results of the sectional structure reflectances calculated as the depth mean show reflectances similar to the approximate values of the reflectances presented by Stelling and Ahrens (1981). It is considered that the reflected wave is well reproduced according to the control of the reflected wave at the boundary and the shape and topography of the structure. Compared with previous studies to examine the diffraction of the wave incident from the breakwater opening, the wave incidence angle and the shape of the diffraction wave are very similar to the theoretical values, but both oblique and rectangular incidence In the case where the direction concentration is small, the diffraction degree is underestimated in some sections with the crest ratio of 0.5 to 0.6.

Light and Scanning Electron Microscopy of Tetragomphius procyonis (Ancylostomatoidea) from Wild Badger (한국산 야생 오소리에서 분리한 오소리구충 (Tetragomphius procyonis)의 광학 및 주사전자현미경 소견)

  • Son, Hwa-Young;Oh, Yoon-Hee;Kim, Hyeon-Cheol;Park, Bae-Keun
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.379-385
    • /
    • 2009
  • Tetragomphius procyonis Baylis & Daubney, 1923 were obtained from the pancreatic duct of a naturally infected Eurasian badger, Meles meles, which was submitted to animal hospital for parasitic diagnosis from Gyeryongsan National Park in Korea. The hookworms were examined by light and scanning electron microscope. The length of body measured male 15.0-18.8 mm, female 21.5-25.5 mm, respectively. In both sex, the ventral cutting plates of oral margin are much reduced and elongated latero-dorsally, the dorsal cutting plate is located long follow doral margin of the oral opening. The buccal capsule is cup-shaped and thicken with four cusped tooth at its base. The copulatory bursa has elongated ventral lobes and their large rays are parallel, while the dorsal lobe with its supporting rays is slightly split in two. The slender spicules are filariform and very long (8.7-9.3 mm), and their tips are fused together. The hookworm has following characters: dorsal cone on the both sex, gubernaculum on the male and terminal spine on the female tail absent; vulva is opening in the juction of the fourths and fifths of the body; dorsal ray with two long stems. The eggs from the uterus are 16 cell stages and those from the rectal feces, 32 cell stages. The size of eggs is 77.48-83.45 ${\times}$ 50.75-63.38 ${\mu}m$.

Evaluation of Punching Shear for Flat Plates Using GFRP Plate Shear Reinforcement (GFRP 판을 전단보강재로 사용한 플랫 플레이트의 뚫림전단 성능 평가)

  • Lee, Young Hak;Kim, Min Sook;Hwang, Seung Yeon;Choi, Jinwoong;Kim, Heecheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.413-420
    • /
    • 2014
  • The purpose of this study is to experimentally investigate the shear behavior of flat plate that reinforced by embedded GFRP(glass fiber reinforced polymer) plate with openings. Shape of the GFRP shear reinforcement is a plate with several openings to ensure perfect integration with concrete. The test was performed on 7 specimens to check shear strength of flat plate that reinforced by GFRP plate. The parameters include the spacing of the shear reinforcement and amount of the shear reinforcement. The result of test showed that when amount of shear reinforcement was increased, shear strength improved. The result of test showed that maximum shear strength was confirmed when spacing of shear reinforcement was 0.3d. The calculation of the shear strength of reinforced flat plate with GFRP plate based on the KCI was compared with the test results.

On the Validity of the Effective Cavity Model with the Transfer Matrix Method as a Frame of Reference In VCSELs (수직 공진기 반도체 레이저에서 전달 행렬 방법과의 비교를 통한 유효 공진기 모델의 타당성 검토)

  • 김태용;김상배
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.7
    • /
    • pp.31-36
    • /
    • 2004
  • In comparison with in-plane lasers, predicting the output power and differential quantum efficiency of Vertical-Cavity Surface-Emitting Lasers(VCSELs) is very difficult due to the distributed Bragg reflector(DBR) layers. Therefore, effective cavity model and transfer matrix method have been adapted in order to calculate the output power and differential quantum efficiency The effective cavity model is inappropriate to calculate output power and differential quantum efficiency while it is practically adequate to calculate the threshold gain and threshold current density The reason is that the effective cavity model can not take account of the absorption in GaAs stack layer right below the metal aperture. In this paper, we have compared the threshold current and differential quantum efficiency calculated by using transfer matrix method with effective cavity model and we have made a study of the validity of the effective cavity model. Finally, we have confirmed the versatility of the transfer matrix method with these studies.

Design Automation of Slab System by the Finite Element Method (유한요소법을 이용한 슬래브 시스템의 설계자동화)

  • 이성우
    • Computational Structural Engineering
    • /
    • v.4 no.4
    • /
    • pp.79-89
    • /
    • 1991
  • New design method of R/C slab system based on finite element method has been presented. The proposed method can substitute inaccurate existing method, which has limitation in its application, and provide accurate and efficient design results for any type of slab system. Isoparametric plate element used in the slab design has been efficiently formulated to save computational time. Reinforcement has been determined by strength design method and compared with code minimum values. Graphical output through comprehensive contour map for resulting moments and designed steel areas has considerably facilitated design process. Accurate shear results from isoparametric plate element enabled to check punching shear in a proper manner. In addition to strength design criteria, serviceability has also been checked by utilizing newly developed inelastic deflection multiplier method. An example for circular slab with opening showed that the proposed method could be applied to design of irregular slab without any difficulty.

  • PDF

Evaluation of Shear Strength for Reinforced Flat Plates Embedded with GFRP Plates (매립형 GFRP 판으로 보강된 플랫 플레이트의 전단강도 평가)

  • Hwang, Seung Yeon;Kim, Min Sook;Lee, Young Hak;Kim, Heecheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • In this study, The purpose of this study is to experimentally investigate the shear behavior of reinforced flat plate embedded with GFRP(glass fiber reinforced polymer) plate with openings. The GFRP shear reinforcement is manufactured into a plate shape with several openings to ensure perfect integration with concrete. The test was performed on 7 specimens. the parameters include the type of reinforcement and amount of the shear reinforcement., From the test, we analysed the crack, failure mode, Strain, load-displacement graph. a calculation of the shear strength of reinforced flat plate with GFRP plate based on the ACI 318-11 was compared with the test results. The results of the experiment indicate that GFRP plate is successfully applied as a shear reinforcement in the flat plate under punching shear.

Comparison of Shear Strength Equation for Flat Plates with GFRP Plate (GFRP 판으로 보강된 플랫 플레이트의 전단강도식에 관한 규준의 비교 분석)

  • Kim, Min Sook;Hwang, Seung Yeon;Kim, Heecheul;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.247-254
    • /
    • 2014
  • In this study, shear test performed to investigate the shear behavior of flat plate that reinforced by embedded GFRP(glass fiber reinforced polymer) plate with openings. Shape of the GFRP shear reinforcement is a plate with several openings to ensure perfect integration with concrete. The test parameters include the distance between the column face and the first line of GFRP plate and number of GFRP plate vertical strip. The result of test showed that when number of GFRP plate vertical strip was increased, shear strength improved. The shear strength for flat plate reinforced GFRP plate in various codes including ACI 318, BS 8110, EUROCODE 2, and KCI were compared to provide more rational approach for reinforced concrete flat plates with GFRP plate.