• Title/Summary/Keyword: 개구부 형태

Search Result 72, Processing Time 0.027 seconds

Analysis of Compression Characteristics of the Steel Plate-Concrete Wall Structures with Openings (개구부가 있는 강판콘크리트 벽체의 압축특성 분석)

  • Choi, Byong-Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.245-256
    • /
    • 2012
  • The objective of this study is to investigate the effect of the openings on the structural behavior of SC walls. The test parameters were with or without the reinforcing of openings and sleeve thickness. The common failure showed that the crack in the concrete progressed with the plate's local buckling between the shear connectors. The failure of the openings showed that the vertical wall of the sleeve buckled toward the opening inside. The plate buckling load showed a similar value with or without the sleeve of the opening, respectively. However, the maximum compressive strength of the specimen without the opening was higher than that of specimen with the opening.

A study on the characteristics of gas explosion with vent area (밀폐공간에서 파열면에 따른 가스폭발특성에 관한 연구)

  • Kim Sang Sub;Chae Jae Ou;Jo Young Do;Jang Gi Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.53-60
    • /
    • 2003
  • Accident occurred by gas explosion in house or building causes damage on lives and properties. To avoid secondary damage, this study drew area ratio of vent area with the experiment for pressure variation with vent area versus building volume by selection of model for different size and shapes of vent area generated by explosion. In addition, Appropriate model was chosen to predict the damage by minimum pressure with the experiment of opening are shapes. This model can prevent secondary damage with the selected vent area and shape to guarantee building safety.

  • PDF

Effect of an Opening on Buckling Strength of Polygonal Section Wind Turbine Tower (다각형 단면 풍력타워 좌굴강도에 대한 개구부의 영향)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.163-163
    • /
    • 2011
  • 풍력타워 기둥구조물에는 유지관리 등의 이유로 출입구 역할을 하는 개구부가 존재하게 된다. 다각형 타워구조물에 개구부형상이 존재하게 되면 압축좌굴 강도에 영향이 있을 것으로 예상되지만, 이를 정량적으로 평가하거나 예측하기는 용이하지 않고 간접적으로 판단할 만한 관련 기준이나 지침도 부족한 상태이다. 이에 최병호 등(2011)에서 다룬 다각형 단면 기둥구조물의 하단에 개구부를 형상화한 수치해석 모델을 수립하고 축방향 압축하중을 재하하는 탄성좌굴 해석 및 비선형비탄성해석을 수행하였다. 본 논문에서는 기존 다각형 단면 기둥모델 중에서 6각형 단면모델에 관해 중점적으로 다루고 있다. 다각형 단면 기둥 해석모델은 단순한 다각형 단면 타워구조에 대해서 뿐 만 아니라, 각 subpanel에 종방향 보강재를 둔 모델에 대해서도 추가적으로 검토하였다. 개구부의 형상은 높이 2000mm, 폭 800mm이며 상하부에 만곡부를 둔 형태이다. 수치해석은 3차원 유한요소해석프로그램인 ABAQUS를 이용하여 수행하였으며, 보강방안으로는 일정범위까지의 모듈 subpanel의 판두께를 보강하는 방안과 edge stiffener를 적용하는 방안에 대해서 검토하였다. 각각의 보강방식에 따른 효과를 비교해 보기 위해 개구부가 없는 모델, 단순히 개구부만 설정한 모델, 판두께를 보강한 모델, edge stiffener로 보강한 모델에 대해 비교해석을 수행하였다. 보강재 없는 단순 다각형 타워구조 모델에 대한 해석결과로부터 개구부로 인한 강도저하는 미미한 수준인 것으로 나타났다. 반면, 종방향 보강재가 적용된 6각형 단면 타워구조 모델에서는 개구부로 인한 강도저감이 22.9%로 높게 나타났으며 상당한 영향이 있는 것으로 분석되었다. 또한 개구부 주변의 판두께 보강이나 edge stiffener보강 등으로 상당한 강도향상 효과가 확인되었으나, 개구부로 인해 손실된 강도 수준을 완전히 회복하는 수준에 미치지 못하는 것으로 나타났다. 따라서, 향후 다양한 보강방식에 대한 보다 포괄적인 변수연구를 통해 개구부의 영향 없이 온전한 다각형 단면 타워 구조의 극한강도에 도달되기 위한 보강 조건에 대해 검토될 필요가 있을 것으로 사료된다.

  • PDF

Application of Advanced Blast Demolition Simulation Method to the Drill and Blast Design for Demolishing Cylindrical Structures (원통형 구조물의 발파해체설계에 대한 최신 발파해체 시뮬레이션 기법의 적용)

  • Park, Hoon;Suk, Chul-Gi;Kim, Seung-Kon
    • Explosives and Blasting
    • /
    • v.26 no.1
    • /
    • pp.7-14
    • /
    • 2008
  • In order to complete successfully the demolition of a silo structure by means of felling method, structural properties and the geometric design of blast mouth have to be considered. In this study, a commercial software, 3-dimensional applied element analysis (3D AEM), was used to investigate the effect of the geometrical parameters of blast mouth on the collapse behavior of the silo structure.

Shear Behavior of Reinforced Concrete Deep Beams with Web Openings (개구부를 갖는 철근콘크리트 깊은 보의 전단거동)

  • 이진섭;김상식
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.619-628
    • /
    • 2001
  • In building construction, openings of the story-height deep beams are usually required for accessibility and service lines such as air conditioning ducts, drain pipes and electric units. It is known that the main parameters affecting the load bearing capacity of deep beams with web openings are size, shape, location and reinforcements of openings. However, there have been no pertinent theories and national design codes for predicting ultimate shear strength of reinforced concrete deep beams with web openings. In this study, the shear behavior of simply supported reinforced concrete deep beams with web openings subject to concentrated loads has been scrutinized experimentally. A total of 34 specimens, the geometry of openings, its reinforcements and shear span to depth ratio, being taken as the experimental variables, has been cast and tested in the laboratory. The effects of these structural parameters on the shear strength and crack initiation and propagation have been carefully checked and analyzed. From the tests, it has been observed that the failures of all specimens were due to shear mechanism and the ultimate strength of specimens varies according to the location of openings, by which the formation of compression struts between the loading points and supports are deterred. All of the test results of specimens have been compared with the formulas proposed by previous researchers. The results were closely coincident with the formulas given by Ray and Kong's equation except for some X series specimens having a larger dimension of openings beyond the geometric limits of proposed equations.

Transmission Cross Section of the Small Aperture in an Infinite Conducting Plane (도체 평판에서 소형 개구의 투과 단면적)

  • Ko, Ji-Hwan;Park, Soon-Woo;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.300-306
    • /
    • 2019
  • Transmission cross section(TCS) is described analytically as $2G{\lambda}^2/4{\pi}$ irrespective of the aperture shapes for various transmission resonant apertures, such as small ridged circular or H-shaped, U-shaped, or Jerusalem cross-shaped apertures in an infinite thin conducting plane. The proposed expression is validated by comparison with the numerical results obtained from the method of moments(MOM). The TCS characteristics of the transmission resonant cavity structure in a thick conducting plane are also studied and the equivalence between the two small aperture structures is reported from the viewpoint of transmission efficiency.

Effect of Reinforcement for Web Opening on Shear Strength of Reinforced Concrete Deep Beams (철근콘크리트 깊은 보의 전단 내력에 대한 개구부 보강 효과)

  • Lee, Jong-Kweon;Choi, Yun-Cheul;Lee, Yong-Taeg
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.699-708
    • /
    • 2007
  • Reinforced concrete deep beams are general structural members used as transfer-girder, pile cap, foundation wall and so on. They have a complex stess formation. Generally, failure mechanisms differ from either continuous deep beams or simple supported deep beams. In continuous deep beams, a negative moment is occurred over intermediate support and the location of maximum moment coincide with high shear force. Therefore, failure usually occurs at this region. While on the other hand, in simple supported deep beam, the region of high shear coincides with the region of low moment. The web opening of deep beams for accepting a facility makes shear behaviors of deep beams more complex and gives rise to an expansion of crack around the opening and a decline of shear capacity of deep beams. Therefore, Engineers must determine a delicate reinforcement method to control a crack and increase a shear capacity. The purpose of this report is a computation of an effective reinforcement method through non-linear finite element method by means of adopting various reinforcement method as variables and a computation of shear capacity formula taking an effectiveness of reinforcement into consideration.

Stability Analysis of Concrete Shear Wall System with Opening (개구부를 갖는 전단벽의 안정해석)

  • Lee, Soo-Gon;Kim, Soon-Chul;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.109-118
    • /
    • 2005
  • A concrete shear wall system is commonly adopted in high-rise residential apartment buildings. In the construction stage, a rectangular opening is often made for the convenience of horizontal movement of workers, and construction materials and equipment. In the case of safety or stability assessment of a shear wall, the cutout part can be a critical factor. Finite element method is adopted to investigate the elastic stability behavior of the perforated unit shear wall. The key analysis parameters are the cutout location and its size. The effect of out-of-plane bending and horizontal shear are also examined in the stability analysis.

Experimental Study of Coupled Shearwalls with different Coupling Member (인방보의 형태에 따른 개구부가 있는 전단벽의 거동 특성에 대한 실험적 연구)

  • Bae, Baek-Il;Choi, Hyun-Ki;Choi, Yoon-Chel;Choi, Chang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.37-40
    • /
    • 2008
  • Many engineers find the way of improving the old building's structural behavior in the remodeling project which is performed using artificial openings for merging two houses. This test was performed to verify the characteristics of coupling beams according to the shape of the openings. One of test specimen has rectangle shape and the other was made by the circle shaped opening and one has coupling member only as slabs. Additionally, three specimens which have openings have 23% ratio in opening area to total wall area. Consequently, solid type which have no opening area shows shear failure. In the case of CW-RBS which have rectangular shaped opening, cracks are developed in coupling beam significantly. And CW-CS which has circular opening failed in shear showing development of diagonal cracks at wall toes and wall mid-height. It is thought that degradation of the wall strength is under the control of the opening shape and coupling beam-wall connection area.

  • PDF

Cyclic Vehavior of composite Beams with Double-Circular Web Openings (쌍원형 개구부를 가진 합성보의 이력거동)

  • 김원기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.162-169
    • /
    • 1999
  • Intentionally weakened girders near the beam-to-colum connection lead ductile failures at the weakened points prior to potential brittle failure at the connection points subjected to strong earthquake. Recent research investigated cyclic behavior of composite beams with a rectangular web opening and find out ductile failure of such beams due to plastic hinge formation of T-section at the four corners of the rectangular opening. But eventual failures of T-sections are resulted from local buckling of T-section having a narrow stem and a narrow bound of plastic hinge formation. This continuing research proposes double-circular opening instead of rectangular one in ofter to improve energy dissipation capacity as well as composite beam strength, Experimental test of two specimens was carried out and its results are compared with those of nonlinear finite element analyses

  • PDF