• Title/Summary/Keyword: 강심알루미늄연선

Search Result 9, Processing Time 0.021 seconds

A Study on Variation of Properties due to Corrosion in Power Lines (전력선의 부식에 의한 물성 변화에 관한 연구)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.259-260
    • /
    • 2016
  • 본 논문에서는 전력선의 부식에 따른 물성 변화에 대한 확인 및 검증을 위한 연구를 수행하였다. 산업단지 및 염해지역에 설치되어진 송전선로에 사용되고 있는 강심알루미늄연선(Aluminum Conductors Steel Reinforced, ACSR)은 타 지역에 비하여 스페이서, 슬리브 등의 접속부에서의 부식 정도가 상당히 빠르게 진행된다. 따라서 현재와 같은 내용연한을 획일적으로 적용할 수 없으므로 설치된 선로의 주위 환경 및 사용되는 부하의 조건 등이 반영된 합리적인 송전선로 운용이 필요하다.

  • PDF

Analysis of Properties according to Degradation in Transmission Line (송전선로의 열화에 따른 특성 분석)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.341-342
    • /
    • 2019
  • 송전선로에 널리 사용되고 있는 강심알루미늄연선(Aluminum Conductors Steel Reinforced, ACSR)은 스페이서와 같은 접속 부위에서 열화가 상당히 빠르게 진행된다. 그런데 현재와 같은 내용연한을 획일적으로 적용할 수 없기 때문에 설치된 송전선로의 주위 환경, 사용되는 부하 조건 등을 고려하여 합리적으로 송전선로를 운용하는 것이 필수적이므로 본 논문에서는 송전선로의 열화에 따른 특성 분석을 위한 연구를 수행하였다.

  • PDF

Corrosion Characteristics of Aluminum Conductors Steel Rainforced wires (강심알루미늄연선의 부식특성)

  • 김용기;장세기;이덕희
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.981-986
    • /
    • 2002
  • ACSR of the catenary wires is corrosion degradation progressed by the effect of atmospheric pollution. ACSR which consists of galvanized steel stranded aluminum. The inside of Steel Reinforced is hot-dipped zinc coating steel wire and it takes charge of tension. If ACSR is exposed in atmosphere, the galvanic corrosion is occurred because it is contacted with aluminum. It is occurred the chemical reaction rapidly so that the local a defect is also occurred. If the catenary wires are exposed in atmosphere of pollution conditions, it may cause to reduce the mechanical strength by corrosion degradation and may cause to damage the wires by micro cracks. Accordingly, this study presents the effects of mechanical properties through the corrosion of ACSR.

  • PDF

Assessment of Tracking Retardant Aluminium Stranded Conductor Aluminium Cald Steel Reinforced Outdoor Cable (ACSR/AW-TR/OC) (트래킹억제형 알루미늄피복강심 알루미늄 절연전선 평가기술)

  • Soh, Jin-Joong;Shim, Dae-Sub;Kim, Kyu-Sub;Yoon, Ki-Teak
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.227-228
    • /
    • 2005
  • 사용중인 OC의 사고가 외물접촉, 자연현상, 일반인 과실 등으로 인하여 전체 배전선로 일시고장의 대부분을 차지하고 있음으로, 피복의 트래킹 성능을 개선하여 수목 및 조류와의 접촉으로 인한 접촉부 전개 집중 시 또는 지지금구의 바인더부에 고전계 인가 시 트래킹에 의한 절연물의 탄화, 침식 등에 의하여 발생할 수 있는 절연파괴 등의 사고 위험을 줄이기 위하여 개발된 제품으로 산악지역 등에서 내트래킹, 내부식성, 수밀성 및 전기적인 특성이 우수하다. 본 평가기술에서는 알루미늄 묘|복강선, 연선 및 절연체의 일반적인 특성과 트래킹성, 도체수밀, 내후성, 밀착도, 교류파괴전압 등의 주요한 평가시험에 대한 방법을 검토하여 평가시험에 적용하여 평가시험시 문제점을 도출하고 평가시험방법을 정립하고자 한다.

  • PDF

Mechanical and Electrical Properties of Aluminum Wires of ACSR Conductors due to Forest Fire (산불에 노출된 강심알루미늄연선 송전선 알루미늄 선재의 기계적 및 전기적 특성 거동)

  • Lee, Won-Kyo;Lee, Jung-Won;Kim, Byung-Geol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.730-735
    • /
    • 2010
  • Forest fire can cause a serious damage to overhead conductors. Therefore, detailed investigation on the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is of critical importance in maintaining transmission line safely. This paper examines the changes of mechanical and electrical properties of flame exposed conductor. Tensile strength (TS) decreased according to increase of forest fire temperature and conductivity changed according to forest fire temperature. Specimens were aluminum conductors of aluminium conductor steel reinforced (ACSR) 410, 240, 480 $mm^2$. In this paper, the electrical and mechanical characteristics of forest fires exposed overhead conductors depending on the diameter of aluminum conductors are presented. It was possible to estimate the degree of deterioration caused by forest fires. The detailed results are given in the paper.

Surface and Component Analysis of Deteriorated ACSR due to a Flame (화염에 열화된 강심알루미늄연선의 표면 및 성분분석)

  • Kim, Young-Dal;Shim, Jae-Myung;Park, Keun-Seok;Jeong, Yun-Mi;Kim, Jae-Kwang;Byun, Jeong-Seop;Lee, Dae-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1966-1971
    • /
    • 2011
  • Generally, the characteristics of the conductor that was affected by forest fire can be analyzed only when the forest fire is accurately modeled and its effect is identified. Few studies have been conducted with a forest fire model for transmission lines, and no results of the examination of the actual test specimens that were exposed to forest fire have been reported. As the deterioration characteristics of a forest fire are difficult to analyze in the actual field, an environment that was similar to that in the field was used in this study. Deterioration was deposited on a wire using an artificial flame experiment device, to analysis the temperature, surface and component characteristics. It seems that this analysis data in this study can be used as the basic data for the database that can be utilized to analyze wires exposed to forest fire and deterioration and to predict the ACSR wire refurnishment life.

Evaluation Method and Evaluation of Anti-icing Coating Material (결빙방지 코팅소재 평가법 및 특성평가)

  • Jo, Hui-Jae;Choe, Jun-Hyeon;Jeong, Yong-Chan;Lee, Su-Yeol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.40-40
    • /
    • 2018
  • 강원도 혹한지역에 설치된 ACSR cable(Aluminium Conductor Steel Reinforced, 강심 알루미늄 연선)에 겔러핑(Galloping), 슬릿점핑(Sleet jumping) 등 빙설해로 인한 단전 및 단락 사고가 발생하여 전력망 운영에 심각한 문제를 초래하고 있다. 특히, 빙설해로 인한 정전사고는 전기 품질의 저하 뿐만 아니라, 국지적으로 발생하여 광범위하게 영향을 미치기 때문에 이에 대한 대응 및 예방기술이 요구되고 있다. 본 연구에서는 ACSR cable의 원 소재인 알루미늄 합금(Al 6061)을 대상으로 낮은 표면에너지를 갖는 결빙방지 코팅소재로 표면처리하여 결빙방지 성능을 향상하고자 하였다. 코팅소재와 얼음과의 접합특성은 결빙접합 특성 시험기를 사용하여 정량적으로 측정하였으며 시험기의 신뢰성 확보를 위해 FEM Modeling을 수행하였다. 결빙특성 지표인 ARF(Adhesion reduction factor)를 적용하여 소재별 결빙방지 효과를 비교 평가하였다. 코팅소재는 현재 해외 국내에서 상용화되고 있는 소수성, 초소수성 소재를 선정하였으며, 결빙접합강도와 매우 밀접하게 연관되어 있는 표면 에너지, 표면 거칠기와의 상관관계를 분석함으로써 결빙방지 코팅소재의 적합성을 평가하였다. 본 연구에서 개발한 상온 경화형 실리콘 러버 코팅소재는 원 소재 Al 대비 약 8~9배 낮은 탁월한 방빙성(Anti-icing) 효과를 나타내었으며, 내구성 또한 상용소재 대비 우수한 특성을 나타내었다.

  • PDF

Evaluation method of icing characteristics for ACSR cable in transmission line by 3D scan (3D 스캔을 활용한 송전선로 ACSR 케이블 결빙특성 평가)

  • Choe, Jun-Hyeon;Jo, Hui-Jae;Jeong, Yong-Chan;Lee, Su-Yeol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.43.2-43.2
    • /
    • 2018
  • 송전 및 배전선 선로에 사용되는 핵심 부품인 ACSR (Aluminum Conductor Steel Reinforced, 강심 알루미늄 연선) cable은 우수한 기계적 성질, 가벼운 중량, 내부식성 특징을 가지고 있어 송전 및 배전선 선로에 핵심 부품으로 사용된다. 하지만, 국내외 혹한 다설 지역에 설치된 ACSR cable에서 빙설해로 인한 단락 또는 지락 사고가 지속적으로 발생하고 있다. 빙설해에 의한 송전선로의 고장은 급격한 전압 강하로 인해 전기 품질에 큰 영향을 주어 민원제기의 주요 원인이 되며, 고장의 파급효과가 국지적으로 발생하지 않고 광범위하게 발생하는 특징이 있기 때문에 이에 대한 대응이 필요한 실정이다. 이러한 문제를 해결하기 위해 ACSR cable의 주 소재인 알루미늄에 대한 판상(Plate) 결빙강도 파악 및 결빙방지 소재개발 연구가 국내외에서 활발히 진행 중이나, 실제 원형의 전선다발이 나선형으로 감겨있는 구조의 ACSR cable 결빙 접합강도를 시험을 통해서 명확히 제시한 연구결과는 아직 보고된 바 없다. 본 연구에서는 실제 송전용 ACSR cable을 대상으로 얼음 간의 주 전단 응력, 파단에너지 등의 결빙특성을 정량적으로 측정할 수 있는 3D 스캔을 활용한 결빙특성 평가시험기를 개발하고, 345kV급 ACSR cable에 대한 결빙특성을 평가결과를 제시하였다. 또한 ACSR cable에 현재 상용화되고 있는 결빙방지 코팅소재를 적용함으로써 코팅소재의 적합성을 ARF(Adhesion reduction factor) 지표를 통해서 비교 평가한 결과를 포함한다.

  • PDF

Diagnosis of Deterioration Grades for Overhead Transmission Lines using Adaptive Neuro-Fuzzy Inference System (적응 뉴로퍼지 추론시스템을 이용한 가공 송전선의 열화등급 진단)

  • 김성덕;이상래
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.57-63
    • /
    • 2003
  • Aluminum Stranded Conductors Steel Reinforced (ACSR) in overhead transmission lines have slowly degraded due to pollutants in the air for a long period of time, so in the 2000, a number of them has been exceeded over their forecasted useful life. Since most of them are faced with assessment their present conditions in regard to economical maintenance, in this paper, we have suggested a method in order to evaluate the current condition of aged conductors by using dominant parameters such as elapsed years, environment index, and conductor configuration. A diagnostic system for predicting the deterioration grades corresponding to the lifetime of aged conductors is described, which is designed as an Adaptive Neuro-fuzzy Inference System (ANFIS) based on knowledge and experiences of experts. Applying this diagnostic system to practical transmission lines in domestic, it is shown that the system can be effectively used as a guide to perform nondestructive diagnosis and economical operation for old ACSR conductors.