• 제목/요약/키워드: 강성저하

Search Result 360, Processing Time 0.03 seconds

Inter-Cell Cooperative Transmission Scheme for Improving Reliability at the Heterogeneous Network (이종 네트워크 환경에서 신뢰성 향상을 위한 인접 셀 간 협력 전송 기법)

  • Kang, Sung-jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.10
    • /
    • pp.1931-1933
    • /
    • 2015
  • This paper proposes inter-cell cooperative transmission scheme in order to improve the reliability of the wireless communication system at the heterogeneous network environments. The heterogeneous network can increase data rate by using existing network technologies. However, degradation of communication performance in the cell edge has been a serious problem. Therefore, this letter proposes an adaptive transmission scheme according to the diverse situations in order to solve this problem.

A Multiple Crack Propagation Analysis considering Initial Flaw and Stress Order in Riveted Specimens (리벳 시편의 초기결함과 응력배열을 고려한 다중균열진전해석)

  • Kim, Jung-Hoon;Zi, Goang-Seup;Kim, Min-Sung;Kong, Jung-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.326-329
    • /
    • 2010
  • 항공기는 전체 수명동안 무수한 반복하중에 노출되기 때문에, 동체에 피로로 인한 다중균열이 불가피하게 발생하게 된다. 이 다중균열은 기체의 강성을 저하시킬 뿐 만 아니라, 종국적으로는 해당 기체구조의 파단을 야기할 수 있다. 초기 결함과 운용 중에 작용되는 응력 스펙트럼은 구조물의 피로수명에 영향을 끼치며 고려해야 한다. 본 논문에서는 초기결함 특성을 파악하기 위한 등가초기결함크기 분포를 산출하고 리벳 시편의 다중균열모델에 대해서 초기결함과 응력배열을 고려한 해석을 수행하였다.

  • PDF

A Study on the Speech Recognition Moduleas Design Using HMM Speech Recognition Algorithm (HMM(Hidden Markov Model) 음성인식 알고리즘을 이용한 효율적인 음성인식 모듈 개발 설계에 관한 연구)

  • 김정훈;류홍석;강재명;강성인;이상배
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.337-340
    • /
    • 2002
  • 본 논문에서는 휠체어 시스템에 화자 독립 고립단어 인식을 위한 임베디드 시스템 설계에 관한 내용을 서술한다. 실제 환경에서는 잡음이 포함되어 있어 인식률을 저하시키므로, 잡음을 제거하는 방식 중 가장 간단한 방식인 스펙트럼 차감법(Spectral subtraction method)을 사용하여 잡음을 제거했다 전처리 단계에서는 12차 LPC&Cepstrum 방식을 사용했고, 인식 알고리즘은 DHMM (Discrete Hidden Markov Model)을 전반부 인식기로 사용했다. 이 알고리즘을 적용하기 위해서는 데이터 간소화를 위해 벡터양자화(Vector Quantization) 처리가 전제되어야한다 또한 인식알고리즘은 인식률을 향상을 위해 후처리 인식기로 신경망(MLP:Multi-layer Perceptron)을 통해서 인식률을 향상시켰다 화자 독립 시스템에 맞는 인식 단어의 구성은 총 7개단어로 남녀 총 25명 목소리로 구성하였다. 그리고 하드웨어 구성은 32-bits floating point 방식인 TMS320C32를 적용했고, 메모리 부분은 4Mbyte로 설계를 했으며, 메인보드의 설계는 현재 완성 단계에 있다.

Localization Improvement in GPS Interfering Spot Using Multiple Sensors of Smartphone (스마트폰의 다중 센서를 이용한 GPS 음영지역 위치추적 개선)

  • Kang, Seong-Jae;Kim, Min-Soo;Jeong, Yong-Ho;Hwang, So-Young;Yu, Don-Hui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.121-123
    • /
    • 2011
  • The accuracy of GPS varies depending on the number of GPS satellites and is declined in GPS interfering spot such as around forest or buildings. This paper proposes a localization improvement algorithm in GPS interfering spot by integrating information of multiple sensors in smartphone. The proposed algorithm is implemented in smartphone and the performance is evaluated in campus area.

  • PDF

A Novel Harmonic Compensation Method to Improve Power Quality in a Wind Power System (계통연계형 풍력발전시스템의 전력 품질 향상을 위한 새로운 고조파 보상기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.492-493
    • /
    • 2014
  • 비선형 부하 등에 의해 계통 전압의 왜곡이 존재하는 경우, 풍력발전 시스템과 같은 분산전원의 출력에는 5차, 7차, 11차 및 13차 고조파와 같은 저차 고조파 성분이 포함 되므로 풍력발전시스템의 전력품질이 저하 된다. 본 논문에서는 기존의 정지좌표계에서의 공진제어기를 이용한 보상기법 보다 연산량이 적고, 계통전압에 다수의 저차 고조파 왜곡이 존재하더라도 효과적으로 고조파를 보상할 수 있는 새로운 고조파 보상기법을 제안하며, 제안된 기법의 우수성을 시뮬레이션과 실험을 통해 증명하였다.

  • PDF

Flexural characteristic changes of fiber reinforced composite $(Fibrekor^{(R)})$ according to water absorption (물 흡수에 따른 fiber reinforced composite $(Fibrekor^{(R)})$의 굽힘 특성 변화)

  • Kim, Sueck-Bum;Kim, Min-Jeong;Kim, Kyung-Ho;Choy, Kwangchul
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.361-370
    • /
    • 2005
  • Fiber reinforced composite (FRC) has been widely used in operative and prosthetic fields of dentistry and its use is expanding into the orthodontic field. The purpose of this study was to examine the changes of flexural properties of FRC reinforced with silica glass fiber (FibreKor, Jeneric/Pentron Inc.. Wallingford. U.S.A.) according to the duration of water absorption. Specimens were grouped according to their shape as round and rectangular cross sections, and were immersed in distilled water at room temperature $(23^{\circ}C)$ for 0 hour 1 hour 1 week. 15 days, 1 mouth and 3 mouths. The number of specimens was 5 for each duration and bending test was done using a torque tester The flexural stiffness after 24 hour water immersion was reduced to 59% for round specimens and 25% for rectangular specimens and after 3 mouths of water immersion it was reduced to 29% and 19% stiffness of the 0 hour-specimen respectively Yield flexural moment after 24 hour water immersion was reduced to 45%for round specimens and 76% for rectangular specimens and after 3 months of water immersion it was reduced to 29% and 60% stiffness of the 0 hour-specimen respectively Ultimate flexural moment after 24 hour water immersion was reduced to 35% for round specimens and 76% for rectangular specimens and after 3 mouths of water immersion it was reduced to 25% and 37% stiffness of 0 hour-specimen respectively. Those results suggested that the flexural stiffness of FibreKor decreased greatly after initial water immersion. Consequently, further research for the maintenance of strength against water will be necessary

Evaluation of Strength and Stiffness Gain of Concrete at Early-ages (조기재령에서 콘크리트의 강도 및 강성 발현 평가)

  • Hong, Geon-Ho;Park, Hong-Gun;Eum, Tae-Sun;Mihn, Joon-Soo;Kim, Yong-Nam
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.237-245
    • /
    • 2010
  • Recently, deflection of the slab during construction periods becoming one of the important issues because of increasing the large-span structures. Early removing the form and support of the slab to achieve the rapid construction cause falling-off in quality of the structures. To reduce these deterioration and make rapid construction, construction of strength and stiffness gain model is needed by the research about the early-age concrete properties. Previous research results indicated that concrete model in existing design codes could not provide the mechanical properties of early age concrete. This paper carried out the concrete compressive strength tests on the curing age at early age stage. Evaluation of the accuracy of compressive strength and modulus of elasticity gain formula in existing various design codes was performed based on this test results, and new design model was proposed. This new model will be useful to develop the new rapid construction methods or prevent the deterioration of the deflection at construction periods. Material tests were performed at 1, 3, 7, 14, 28 curing days, total 159 cylinder style specimens were tested. Based on analyzing the test results, the relationship between compressive strength and modulus of elasticity at early age was proposed.

Effects of Bar Deformation Height on Bond Degradation Subject to Cyclic loading (반복하중시 철근 마디높이에 따른 부착 손상특성)

  • Lee, Jae-Yuel;Kim, Byong-Kook;Hong, Gi-Suop;Choi, Oan-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • One of the reasons for brittle failure in reinforced concrete structures subjected to severe earthquake is due to large local bond-slippage of bars resulting in fast bond degradation between reinforcing bars and concrete. This study aims to evaluate effects of bar deformation height on bond performance, specially, bond degradation under cyclic loading. Bond test specimens were constructed with machined bars with high relative rib areas. The degree of confinement by transverse bars is also another key parameters in this bond test. From test results, amounts of energy dissipation are calculated and compared for each parameter. Test results show that bond strength and stiffness drops significantly as cycles increases. The confinement and high relative rib area are effective to delay bond degradation, as the reduction of bond strength of cyclic loading compared to monotonic loading decreased for bars with large confinement and high relative rib areas. The energy dissipation also increases as the degree of confinement and relative rib area increases. However, tested bars with very high rib areas show that the bond may be damaged at relatively small slip because of high stiffness. The study will help to understand the bond degradation mechanism due to bar deformation height under cyclic loading and be useful to develop new deformed bars with high relative rib areas.

A Study on the Evaluation of Smear Zone by In-situ Tests (현장시험에 의한 Smear Zone의 평가)

  • 이장덕;구자갑
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.207-216
    • /
    • 2003
  • To evaluate the smear zone caused by the drain installation, 10 piezometers were installed in the typical soft ground in the western coastal area of Korea. The dynamic pore water pressure developed during the drain installation was monitored using piezometers installed at a distance of 10cm, 20cm, 30cm, 40cm and 50cm from the location of the drain. The decay of pore pressure with time after pushing piezometers to depths of 5 meters and 7 meters during the drain installation was monitored to assess flow and consolidation characteristics of the soil after disturbance of the soil due to the drain installation. The drain installation results in shear strain and displacement of the soil and it decreases the permeability of the soil. Hence, the comparison between dissipation of the pore water pressure process in 10 pieszometers before as well as after installation of the drain indicated the diameter of disturbance zone and smear zone, which is related to the cross-sectional dimension of the mandrel. In addition, Cone-pressuremeter(CPM) tests were performed to obtain rigidity index of the soil for an interpretation of the dissipation processes. It has been evaluated by in-situ tests that the smear zone is from 3.0 to 3.6 times of the cross-sectional dimension of the mandrel. The hydraulic conductivity expressed in terms of the coefficient of consolidation after the drain installation was calculated from 3 to 8 times decrease evaluated by Teh & Houlsby equation and CPM test results.

A Study on the Thermal Treatment Conditions of Retort Pouched Fried Fish Meat Paste 1. Influence of Thermal Treatment Conditions on Quality (레토르트파우치 튀김어묵의 열처리조건에 관한 연구 1. 열처리조건이 품질에 미치는 영향)

  • HA Jin-Hwan;LEE Eung-Ho;KIM Jin-Soo;JI Seung-Gil;KOO Jae-Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.6
    • /
    • pp.573-581
    • /
    • 1987
  • The fish meat paste products are rapidly growing in its production. However, the recent prohibition of AF-2 gives a lot of difficulties in the marketing of fish meat paste products manufactured ty the conventional procedures. The present study aims to obtain the optimal conditions for retaining tile quality of the fish meat paste products with long shelf-life on the market. The fried fish meat paste was sealed in the retort pouches and sterilized under the conditions which the Fo value designated to 6. The effects of the sterilization temperature and the diameter of the products on the quality factors such as jelly strength, water holding capacity, texture and in vitro protein digestibility were investigated. The jelly strength and hardness increased as the sterilization temperature increased. On the other hand, there were no differences found in water holding capacity and elasticity. Of the samples, product with diameter of 12mm showed the highest values of jelly strength, hardness, L values and in vitro protein digestibility which sterilized at $124^{\circ}C$. However. tile results of the organoleptic tests showed rather score in the products with diameter of 16 mm than 12 mm which were sterilized at $124^{\circ}C $. From the results described above, it was concluded that the fried fish meat paste products with 16 mm or less in a diameter which were sterilized at higher temperature could keep high quality.

  • PDF