• Title/Summary/Keyword: 강선

Search Result 334, Processing Time 0.023 seconds

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique (압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상)

  • Rhyou, In-Hyeok;Suh, Bo-Gun;Kim, Hyung-Jin;Chung, Chae-Ik;Kim, Kyung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We wanted to evaluate the surgical results of early mobilization after rigid fixation of small coronoid fracture using the tension band technique Materials and Methods: Eight cases of coronoid fracture were fixed with the tension band technique and using K-wire and wire through the medial approach. All the cases were Regan-Morrey type 2. According to O'Driscoll, they were classified as 5 cases of the tip type (subtype 2) and 3 cases of the anteromedial type (1 case of subtype 2, and 2 case of subtype 3). The associated collateral ligament injuries (6 cases) and radial head/neck fractures (4 cases) were managed simultaneously. After immobilization for 5~7 days, active ROM exercise with a fitted hinge brace started and continued till postoperative 6 weeks. The patients were assessed for pain, ROM and functional disability using the Mayo elbow performance score (MEPS) at an average of 11 months (range: 6~28 months). The ulnar nerve symptoms were also investigated. Results: We observed solid union in all the coronoid fractures without hardware failure. An average of 2.2 wires (range: 2~4) were used. The mean extension was $3^{\circ}$(range: $0^{\circ}\sim25^{\circ}$), the mean flexion was $137^{\circ}$(range: $130^{\circ}\sim140^{\circ}$), the mean pronation was $69^{\circ}$(range: $45^{\circ}\sim90^{\circ}$) and the mean supination was $78^{\circ}$(range: $45^{\circ}\sim90^{\circ}$). The mean MEPS was 96 (range: 65~100). Ulnar nerve symptoms occurred at postoperative one day and persisted in one patient with the terrible triad of taking radial head excision and residual medial instability. Conclusion: The tension band technique uses easily obtained, economic K-wires and the wire was strong enough to permit early elbow ROM exercise and the technique might improve the elbow function. It was especially useful for fixation of multiple small fragments.

Pullout Characteristics of MC Anchor in Shale Layer (셰일지반에 설치된 MC앵커의 인발특성)

  • Lee, Bongjik;Kim, Josoon;Lee, Jongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.53-61
    • /
    • 2012
  • In this study, the research on MC anchor has been developed as composite type has done. MC anchor exerts bearing pressure on pre-bored hole where the end fixing device is expanded. Therefore, the uplift capacity is to be increased and it has the characteristics that the anchor body is not eliminated from the ground even if the grouting is not carried out properly. Furthermore, it reduces the loss of tension and raises the construction availability by inserting the reinforced bar as well as the anchor cable, while it can improve the long-term stability because the nail is expected to play the role when the loss of the anchor cable is occurred in a long-term. However, because the resistance mechanism of the compound anchor such as MC anchor is different from friction anchor, the estimation method of the uplift capacity by the frictional force of the ground and the grout is not proper. Particularly, in domestic cases, the problem to overestimate or underestimate the uplift capacity is expected because the design method considering the soil characteristics about the compound anchor has not been developed. Therefore, in this study, in order to evaluate the characteristics of MC anchor and a kind of compound anchor, we measured the uplift, the tension and the creep by nine anchors tests in shale ground that the fluctuation of the strength is great. In addition, we analyzed the test result comparing to the result of the general friction anchor and evaluated the characteristics of MC anchor movement to gather the results. As a result of the test, we found the effect that the uplift capacity is increased in shale ground comparing to the general friction anchor.

Operative Treatment of Symptomatic Os Acromiale (견봉 골의 수술적 치료)

  • Ji, Jong-Hun;Kim, Weon-Yoo;Park, Sang-Eun;Kim, Young-Yul;Moon, Chang-Yun
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2008
  • Os acromiale is the rare shoulder disease and its treatment is controversial. Despite conservative treatments for 6 months include medication, exercise, physical therapy and subacromial steroid injections, operative treatment for uncontrolled symptomatic Os acromiale is considered the treatment of choice. Operative treatment includes excision, arthroscopic or open reduction and internal fixation with a bone graft. Open reduction with tension band wiring and a bone graft is now the preferred treatment. We experienced 8 patients with symptomatic Os acromiale from March, 2001 to March, 2006. The average patient's age was 45 years and the man and women ratio were 2: 6. All 8 cases of symptomatic Os acromiale of the mesoacromion were treated with open reduction and internal fixation using tension-band wiring. The preoperative ASES($47.3\pm24.4$) and UCLA ($16.6\pm5.8$)scores were improved to $88.8\pm7.3$ and $31.5\pm1.9$, respectively, at the 2 year follow up. The overall UCLA score showed 1 excellent result and 7 good results. We think that symptomatic Os acromiale is a specific disease entity, and open reduction and internal fixation using tension-band wiring with K-wire is a good treatment modality.

Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems (포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동)

  • Han, Sang-Whan;Kee, Seong-Hoon;Kang, Tomas H.K.;Cho, Jong;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.595-602
    • /
    • 2006
  • An experimental study was conducted to investigate seismic behaviour of post-tensioned(PT) exterior slab-column connections used for the purpose to resist gravity loads only. For these, 2/3-scale, two PT post-tensioned exterior connections with two different tendon arrangement patterns and one conventional reinforced concrete(RC) exterior connection was tested under quasi-static, uni-directional reversed cyclic loading. During the lateral testing, gravity forces transferred to the column were kept constant to closely simulate a moment to shear ratio of a real building. One of the objectives of this study was to assess the necessity and/or the quantity of bottom bonded reinforcement needed to resist moment reversal which would occur under significant inelastic deformations of the adjacent lateral force resisting systems. The ACI 318 and 352 provisions for structural integrity were applied to provide the bottom reinforcement passing through the column for the specimens. Prior test results were also collected to conduct comparative studies for some design parameters such as the tendon arrangement pattern, the effect of post-tensioning forces and the use of bottom bonded reinforcement. Consequently, the impact of tendon arrangement on the seismic performance of the PT connection, that is lateral drift capacity and ductility, dissipated energy and failure mechanism, was considerable. Moreover, test results showed that the amount of bottom reinforcement specified by ACI 352. 1R-89 was sufficient for resisting positive moments arising from moment reversal under reversed cyclic loads. Shear strength of the tested specimens was more accurately predicted by the shear strength equation(ACI 318) considering the average compressive stress over the concrete($f_{pc}$) due to post-tensioning forces than that without considering $f_{pc}$.

Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report - (관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 -)

  • Kim, Hyung-Sik;Koh, Il-Hyun;Kim, Sung-Guk;Chun, Yong-Min;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.94-98
    • /
    • 2011
  • Purpose: We present a case of anterior glenoid rim comminuted fracture that was treated with arthroscopic reduction and an AO headless compression screw (HCS) fixation. Materials and Methods: A 31-year old man complained of left shoulder pain after falling down on stairs. The anterior glenoid comminuted fragments were arthroscopically reduced. Fixation with an AO HCS was done after placement of 1.1 mm Kirschner wire as a guide pin through a standard cannulated anterosuperior portal. Results: Twelve months after the operation, union of the fracture was achieved and the range of motion was fully recovered. He did not complain of any discomfort during his activities of daily living. Conclusion: An AO HCS had various screw sizes and this was good for fixation of a small glenoid fracture and a long drill bit and screw driver were useful for fixation of deep seated glenoid fracture. A short guide wire could be replaced by a 1.1 mm K-wire. An AO HCS was useful for fixation of an anterior glenoid rim comminuted fracture.

Seismic Performance and Retrofit of Reinforced Concrete Two-Column Piers Subjected to Bi-directional Cyclic Loadings (이축반복하중을 받는 2주형 철근콘크리트 교각의 내진성능과 보강)

  • Chung, Young-Soo;Park, Chang-Kyu;Lee, Ho-Yul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.47-55
    • /
    • 2006
  • Seismic performance and retrofit of reinforced concrete (RC) two-column piers widely used at roadway bridges in Korea was experimentally evaluated. Ten two-column piers that were 400 mm in diameter and 2,000 mm in height were constructed. These piers were subjected to hi-directional cyclic loadings under a constant axial load of $0.1f_{ck}A_g$. Test parameters were the confinement steel ratio, loading pattern, lap splice of longitudinal reinforcing bars, and retrofitting method. Specimens with lap-spliced longitudinal bars were retrofitted with steel jacket, pre-stressing steel wire, and steel band. Test result showed that while the specimens subjected to bi-directional lateral cyclic loadings which consisted of two main amplitudes in the transverse axis and two sub amplitudes in longitudinal axis, referred to as a T-series cyclic loadings, exhibited plastic hinges both at the top and bottom parts of the column, the specimens subjected to bi-directional lateral cyclic loadings in an opposite way, referred to as a L-series cyclic loadings, exhibited a plastic hinge only at the bottom of the column. The displacement ductility of the specimen under the T-series loadings was bigger than that of the specimen under the L-series loadings. Specimen retrofitted with pre-stressing steel wires exhibited poor ductility due to the upward shift of the plastic hinge region because of over-reinforcement, but specimens retrofitted with steel jacket and steel band showed the required displacement ductility. Steel band can be an effective retrofitting scheme to improve the seimsic performance of RC bridge piers, considering its practical construction.

Behavior of RC Beam Strengthened with Advanced Lifting Hole Anchorage System (개선된 인양홀을 이용한 정착장치로 보강된 RC 보의 거동)

  • Oh, Min-Ho;Kim, Tae-Wan;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.91-99
    • /
    • 2010
  • In order to strengthen RC structures, various strengthening methods have been used. Particularly, external tendon strengthening method is very popular method to strengthen damaged structures in terms of efficiency, ease, economics. In this study, improved anchorage elements using the lifting hole were proposed to strengthen PSC or RC girder without any damage. Two types of anchorage elements were proposed and these elements were applied on six RC beams. Also, three types of existing anchorage elements were applied on three RC beams. Otherwise, any anchorage element was not applied on one RC beam to used as a control beam. To analyse behavior of these elements, static load tests were carried out. Test variables were anchorage shapes, prestressing level on the steel bar and tendon profiles. Deflections, strains and modes of failure were recorded to examine the strengthening effects of the beams. Ductility index and tendon stress were analyzed by comparing cracking load, yielding load and ultimate load. As a result, proposed anchorage elements using lifting hole were superior to existing anchorage elements in terms of strengthening effect and furthermore, they showed ductile behavior based on energy method.

Structural Characteristics Analysis of Steel Box Girder Bridge being stressed the PS Steel Wires at the Upper Slab of the Intermediate Support (지점부 상부슬래브에 PS강선 긴장된 강 박스거더교의 구조적 특성 분석)

  • Cha, Tae-Gweon;Jang, Il-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.1-7
    • /
    • 2021
  • The concrete deck slab at the continuous span support of the steel box girder bridge is a structure that is combined with the upper flange. It is a structure that can cause tension cracks in the deck slab at the support causing problems such as durability degradation in long span bridges. This is because the tensile stress in the longitudinal direction of the slab exceeds the design tensile strength due to the effects of dead load and live load when applying a long span. Accordingly, it is necessary to control tensile cracking by adding a reinforcing bar in the axial direction to the slab at the support and to introduce additional compressive stress. To solve this problem, a structural system of a steel box girder bridge was proposed that introduces compressive stress as PS steel wire tension in the tensile stress section of the upper slab in the continuous support. The resulting structural performance was compared and verified through the finite element analysis and the steel wire tension test of the actual specimen. By introducing compressive stress that can control the tensile stress and cracking of the slab generated in the negative moment through the tension of the PS steel wire, it is possible to improve structural safety and strengthen durability compared to the existing steel box girder bridge.

KSLV 추진기관 종합시험설비 피해 사고 예측 모델 해석

  • Lee, Jung-Ho;Kang, Sun-Il;Yu, Byung-Il;Kim, Yong-Wook;Cho, Sang-Yeon;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.163-170
    • /
    • 2005
  • According to the KSLV program of KARI, it is planed to develop various launch vehicle and satellite 10 years hereafter. Large-scale test facilities, such as ReTF and PTA-II, are needed to fulfill this launch vehicle/satellite development project. The authors intend to arrange and describe various indexes that are needed in test facility design, construction and operation process. This technical paper is describing model analysis of damage prediction of accident in KSLV Integrated Propulsion System Test Facility based on propellant storage quantity and layout. In addition, the result can be used to produce safer design of test facility.

  • PDF