• Title/Summary/Keyword: 강북삼성병원

Search Result 113, Processing Time 0.021 seconds

Reliability of OperaVOXTM against Multi-Dimensional Voice Program to Assess Voice Quality before and after Laryngeal Microsurgery in Patient with Vocal Polyp (성대 용종 환자의 후두미세수술 전후 음성 평가에서 OperaVOXTM와 Multi-Dimensional Voice Program 간의 신뢰도 연구)

  • Kim, Sun Woo;Kim, So Yean;Cho, Jae Kyung;Jin, Sung Min;Lee, Sang Hyuk
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.31 no.2
    • /
    • pp.71-77
    • /
    • 2020
  • Background and Objectives OperaVOXTM (Oxford Wave Research Ltd.) is a portable voice analysis software package designed for use with iOS devices. As a relatively cheap, portable and easily accessible form of acoustic analysis, OperaVOXTM may be more clinically useful than laboratory-based software in many situations. The aim of this study was to evaluate the agreement between OperaVOXTM and Multi-Dimensional Voice Program (MDVP; Computerized Speech Lab) to assess voice quality before and after laryngeal microsurgery in patient with vocal polyp. Materials and Method Twenty patients who had undergone laryngeal microsurgery for vocal polyp were enrolled in this study. Preoperative and postoperative voices were assessed by acoustic analysis using MDVP and OperaVOXTM. A five-seconds recording of vowel /a/ was used to measure fundamental frequency (F0), jitter, shimmer and noise-to-harmonic ratio (NHR). Results Several acoustic parameters of MDVP and OperaVOXTM related to short-term variability showed significant improvement. While pre-operative value of F0, jitter, shimmer, NHR was 155.75 Hz (male: 125.37 Hz, female: 183.37 Hz), 2.20%, 6.28%, 0.16, post-operative values of these parameter was 164.34 Hz (male: 129.42 Hz, female: 199.26 Hz), 2.15%, 5.18%, 0.14 Hz in MDVP. While pre-operative value of F0, jitter, shimmer, NHR was 168.26 Hz (male: 135.16 Hz, female: 201.37 Hz), 2.27%, 6.95%, 0.26, post-operative values of these parameters was 162.72 Hz (male: 128.267 Hz, female: 197.18 Hz), 1.71%, 5.36%, 0.20 in OperaVOXTM. There was high intersoftware agreement for F0, jitter, shimmer with intraclass correlation coefficient. Conclusion Our results showed that the short-term variability of acoustic parameters in both MDVP and OperaVOXTM were useful for the objective assessment of voice quality in patients who received laryngeal microsurgery. OperaVOXTM is comparable to MDVP and has high intersoftware reliability with MDVP in measuring the F0, jitter, and shimmer

Pathological Factors Affecting DNA Quality in BRAF, EGFR, and KRAS Gene Molecular Tests (BRAF, EGFR, KRAS 유전자 분자병리검사에서 DNA 품질에 영향을 미치는 병리학적인 인자에 관한 연구)

  • Yun, Hyon-Goo;Kim, Bo-Ra;Lee, Joo-Mi;Song, Eun-Ha;Kim, Dong-Hoon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.4
    • /
    • pp.381-388
    • /
    • 2020
  • The quality control of pathological specimens is important for accurate molecular pathology testing. This study evaluated that specimen factors affecting the DNA quality during tissue processing and sample types for BRAF, EGFR, and KRAS mutations tests. One thousand seven hundred and seventy-two molecular pathology tests were investigated for the factors influencing the DNA quality, such as sample type, formalin fixation time, and reexamination status. Cytology samples stored in a saline solution had better DNA quality than commercial cytology preservation. Tissue samples fixed in formalin within 24 hours had better DNA quality than the samples fixed over 24 hours. Between the types of samples, fresh tissue samples and tissue samples with a high tumor cell density had relatively better DNA quality than the formalin-fixed paraffin-embedded (FFPE) tissues and cytology specimens. Of real-time PCR, the non-PNA Ct value increased proportionally with samples held for longer than 24 hours in formalin, and that the formalin-fixed time affects the sample DNA quality. In conclusion, the appropriate tumor cellularity and 10% neutral formalin fixation time are the most important factors for maintaining the DNA quality. These factors should be managed properly for an accurate pathological molecular test to ensure optimal DNA quality.

Analysis of the Effect of Intralesional Steroid Injection on the Voice During Laryngeal Microsurgery (후두 미세수술 중 병변 내 스테로이드 주입이 음성에 미치는 효과 분석)

  • Jae Seon, Park;Hyun Seok, Kang;In Buhm, Lee;Sung Min, Jin;Sang Hyuk, Lee
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.3
    • /
    • pp.166-171
    • /
    • 2022
  • Background and Objectives Vocal fold (VF) scar is known to be the most common cause of dysphonia after laryngeal microsurgery (LMS). Steroids reduce postoperative scar formation by inhibiting inflammation and collagen deposition. However, the clinical evidence of whether steroids are helpful in reducing VF scar formation after LMS is still lacking. The purpose of this study is to determine whether intralesional VF steroid injection after LMS helps to reduce postoperative scar formation and voice quality. Materials and Method This study was conducted on 80 patients who underwent LMS for VF polyp, Reinke's edema, and leukoplakia. Among them, 40 patients who underwent VF steroid injection after LMS were set as the injection group, and patients who had similar sex, age, and lesion size and who underwent LMS alone were set as the control group. In each group, stroboscopy, multi-dimensional voice program, Aerophone II, and voice handicap index (VHI) were performed before and 1 month after surgery, and the results were statistically analyzed. Results There were no statistically significant differences in the distribution of sex, age, symptom duration, occupation and smoking status between each group. Both groups consisted of VF polyp (n=21), Reinke's edema (n=11), and leukoplakia (n=9). On stroboscopy, the lesion disappeared after surgery, and the amplitude and mucosal wave were symmetrical on both sides of the VFs in all patients. Acoustic parameters and VHI significantly improved after surgery in all patients. However, there was no significant difference between the injection and control group in most of the results. Conclusion There was no significant difference in the results of stroboscopy, acoustic, aerodynamic, and subjective evaluation before and after surgery in the injection group and the control group.

Gastrointestinal Symptoms in Diabetes Occur Long before Diabetic Complications (당뇨병 합병증 발생 이전의 위장관 증상)

  • Hwanseok Jung;Eun-Jung Rhee;Mi Yeon Lee;Jung Ho Park;Dong Il Park;Woo Kyu Jeon;Chong Il Sohn
    • The Korean Journal of Medicine
    • /
    • v.99 no.4
    • /
    • pp.210-218
    • /
    • 2024
  • Background/Aims: Gastrointestinal (GI) manifestations are common in patients with diabetes complications, such as autonomic neuropathy. However, the prevalence of GI symptoms before the development of diabetes complications is unclear. Methods: We conducted an interview survey of functional GI disorders among patients with diabetes visiting the endocrinology clinic of a general hospital using the Rome III criteria. The survey consisted of questions regarding functional dyspepsia, irritable bowel syndrome, and functional constipation, including functional defecation disorder. Results: In total, 509 patients were included in the analysis. The patients were divided into three groups: prediabetes (n = 115), diabetes without neuropathy (n = 275), and diabetes with neuropathy (n = 119). With regard to GI symptoms, the prevalences of functional dyspepsia in the prediabetes, diabetes without neuropathy, and diabetes with neuropathy groups were 16.52%, 27.27%, and 23.53%, respectively; those of irritable bowel syndrome were 8.70%, 11.68%, and 16.81%, respectively, and those of functional constipation were 8.85%, 11.85%, and 15.25%, respectively. In the subgroup analysis, symptoms of postprandial distress syndrome (e.g., postprandial fullness and early satiety) were more prevalent than symptoms of epigastric pain. In the constipation group, symptoms of pelvic outlet obstruction (such as the sensation of anorectal obstruction or blockage and the need for manual maneuvers to facilitate defecation) were more prevalent than symptoms of slow-transit constipation. Conclusions: The prevalence of functional GI disorders increases with diabetes severity. Diabetes-related GI symptoms appear long before the onset of diabetes complications.