• Title/Summary/Keyword: 강도 열화

Search Result 579, Processing Time 0.027 seconds

A Study on the Development of Super Low-loss Type Pole Transformer Using the Hybrid Insulation (혼합절연을 이용한 초저손실급 주상변압기 개발에 관한 연구)

  • Min, Yun-Hong;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.84-93
    • /
    • 2007
  • The pole transformer is one of the most important facility to insure the stability of electric power supply. which distributes electricity to customers directly. However there are a lot of defects which are caused by manufacturing fails(in 3 years) or deterioration (in 13 years), so we need a more improved transformer which insures quality. This thesis talks about the development of the new-type transformer using the hybrid insulation that is durable thermally, mechanically, and electrically. It would show how to lay out and produce the transformer using the hybrid insulation. And finally we are sure that we could increase the utilization rate of a transformer by 160% as compared with its own capacity through the overload test. Also, we carried out the examination about the short-circuit and insulation with a 100[kVA] model transformer, so that we expound the analysis of magnetic-mechanical forces intensity and the measure for improving short-circuit efficiency.

A Study on the Performance Development of Sewage Concrete by Application of Antibiotics (항균제 도포에 의한 하수시설 콘크리트의 성능향상에 관한 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Khil, Bae-Su;Cho, Bong-Suk;Lee, Eui-Bae
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.371-378
    • /
    • 2006
  • Recently sewage facilities mainly consisted of concrete structures are being deteriorated seriously by biodeterioration originated from sulfur-oxidizing bacteria. In this study, to prevent biochemical corrosion of the sewer concrete, antibiotics which prevent growth of sulfur-oxidizing bacteria were developed and antimicrobial performance of it was investigated. After that, to consider applicability of antibiotics to concrete, physical properties of concrete covered with antibiotics were investigated. As a results of the study, it was proved that the antimicrobial performance of antibiotics was available. Also compressive strength and bond strength of concrete didn't closely connected with antibiotics, and resistance to abrasion, water absorption, air permeability, carbonation, salt damage and chemical attack of concrete was improved remarkably by covering with it.

Influence of low temperature degradation on the bond strength and flexural Strength of veneered Zirconia(3Y-TZP) (저온열화가 도재전장 지르코니아의 결합강도와 굴곡강도에 미치는 영향)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.193-202
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of pre-treatment of core and hydrothermal treatment on the bond strength and flexural strength of ceramic veneered zirconia. Methods: 3Y-TZP specimens(KaVo Zr, $25mm{\times}3mm{\times}1mm$)were prepared by five pre-treatment methods and divided into seven groups including control two groups, subsequently the specimens veneered with the E-MAX ceram according to manufacturer's information(total specimen thickness 1.5mm). Two groups from ceramic-zirconia specimens(n=105, n=15 per group)were assigned into two experimental fatigue conditions, namely storage in an autoclave at $134^{\circ}C$ for 5h, thermo-cycling(3,000cycles, between 5 and $55^{\circ}C$, dwell time 45s, transfer time 2s). A flexural strength test was performed in a universal testing machine(crosshead speed: 0.5mm/min). Data were statistically analyzed using one-way ANOVA and Tukey's test(${\alpha}$=0.05). Results: The ceramic-zirconia bond strength value for liner application group(LLW, $27.3{\pm}3.8$) were significantly lower than those of the pre-treatment groups($30.72{\pm}5.3$). The ceramic-zirconia bond strength and zirconia flexural strength was not affected by thermo-cycling(p>0.05), whereas it was affected by storage in an autoclave at $134^{\circ}C$ for 5h(p<0.05). Conclusion: The results indicated that the ceramic-zirconia bond strength and zirconia flexural strength was affected by low temperature degradation.

Acoustic Emission of Heat Treated Compacted Graphite Iron under 873~1173 K (873~1173 K에서 열처리된 강화흑연강(Compacted Graphite Iron, CGI)의 음향방출 특성)

  • Nam, Ki-Woo;Ahn, Byung-Kun;Lee, Soo-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.415-421
    • /
    • 2013
  • CGI is gaining popularity in applications that require either greater strength, or lower weight than cast iron. Recently, compacted graphite iron has been used for diesel engine blocks, turbo housings and exhaust manifolds. This paper were assessed acoustic emission characteristics according to the mechanical properties change of degraded CGI340 during 1-24 hours at 873~1173 K. In results of pencil lead fracture test, the dominant frequency and the velocity of base metal were 97 kHz and 5490 m/sec, respectively. The base metal in a tensile test was obtained relatively high dominant frequency. However, the heat treated materials, the longer the heat treatment time, the higher the heat treatment temperature, were obtained in the area of lower frequencies. This phenomenon appears by long-term use.

The Model to Generate Optimum Maintenance Scenario for Steel Bridges considering Life-Cycle Cost and Performance (강교량의 최적 유지관리 시나리오 선정 모델)

  • Park, Kyung Hoon;Lee, Sang Yoon;Kim, Jung Ho;Cho, Hyo Nam;Kong, Jung Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.6
    • /
    • pp.677-686
    • /
    • 2006
  • In this paper, a more practical and realistic method is proposed to establish the lifetime optimum maintenance strategies of the deteriorating bridges considering the life-cycle performance as well as life-cycle cost. The genetic algorithm is applied to generate the set of maintenance scenarios that is the multi-objective combinatorial optimization problem related to lifetime performance and cost as separate objective functions, and the technique to select optimum tradeoff maintenance scenario is presented. Optimum maintenance scenarios could be generated not only at the individual member level but also at the system level of the bridge. Through the analytical results of applying the proposed methodology to the existing bridge, it is expected that the methodology will be effectively used to determine the optimum maintenance strategy for introducing a real preventive maintenance system and overcoming the limits of existing maintenance methods.

Integral Method of Stability Analysis and Maintenance of Slope (비탈면 안정해석과 유지관리의 통합해석기법)

  • Park, Mincheol;Yoo, Byeongok;Baek, Yong;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.3
    • /
    • pp.27-35
    • /
    • 2016
  • Even if the various data analyzing methods were suggested to examine the measured slope behaviors, it is difficult to find methods or procedures for connecting the analyzed results of slope stability and measured slope data. This research suggests the analyzing methods combing the stability analysis and measured data based on progressive failure of slope. Slope failure analysis by time degradation were calculated by strength parameters composed of strength reduction coefficients, also which were compared to the measured data according to the variations of safety factor and displacement of slopes. The accumulated displacement curve were shown as 3rd degree polynomials by suggested procedures, which was the same as before researches. The reverse displacement velocity curves were shown as linear function for prediction of brittle slope failures, also they were shown as 3rd degree polynomials for ductile slope failures, which were the same as the suggested equation by Fukuzono (1985) and they were very similar behaviors to the in-situ failure cases.

A study on fatigue properties of GFRP in synthetic sea water (인공해수중 GFRP의 피로특성에 관한 연구)

  • 김연직;임재규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1351-1360
    • /
    • 1993
  • The fatigue behavior of GFRP composites is affected by environmental parameters. Therefore, we have to study on effect of sea water on fatigue behavior of GFRP composites as to maintain the safety and confidence in design of ocean structure of GFRP. In this paper, we investigated the fatigue properties of chopped strand glass mat/polyester composite in synthetic sea water. (pH 8.2) In case of the glass fiber (CSM type) reinforced polyester composite materials, the fatigue crack in the both dry and wet specimens tested in air or synthetic sea water occurred at the initial of cycle. Thereafter, it was divided with two regions that one decreased with the crack extension and the other increased with the crack extension. The transition point occurred during the crack propagation shifted to high ${\Delta}K$ value as load increase but its point is not changed regardless of immersion or test environment under a constant load. The synthetic sea water degrades the bond strength between fiber and matrix, thereby the tendency of rapid deceleration and acceleration of the crack growth was appeared.

A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid (고경질 도막을 이용한 PET 필름 접합공법의 필름 표면처리 방법에 따른 접합특성 연구)

  • Lee, Jong-Suk;Kim, Young-Sam;Shin, Hong-Chol;Kim, Young-Geun;Kang, Chung-Mo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.153-159
    • /
    • 2014
  • This research reviewed the joint and duration characteristics depending on the surface treatment condition and lap spliced length in the PET film jointing method using the high hardness liquid material. As a result, the corona discharge treatment was improved to the contact angle, joint tensile strength, and joint peel resistance compared to non-treatment. Particularly, a surface treatment E (Corona discharge + Primer + PU bond + Polyester fabric) turned out to the best, and especially when the lap spliced length is longer than 15mm, stable joint performance was secured under the long term deterioration treatment of 16 weeks. Thus, the joint is considered to be applicable as the water-proof material.

$CO_2$ 클러스터 표면 처리를 이용한 그래핀 특성 향상에 관한 연구

  • Choe, Hu-Mi;Kim, Jang-A;Jo, Yu-Jin;Hwang, Tae-Hyeon;Lee, Jong-U;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.655-655
    • /
    • 2013
  • 그래핀은 높은 전자 이동도, 열전도도, 기계적 강도, 유연성 등의 고유한 특성으로 다양한 분야에 응용하기 위한 연구가 수행되고 있으며, 특히 전자 소자에의 적용에 관한 연구가 활발히 이루어지고 있다. 전자 소자에 적용하기 위해서는 성장 및 물성에 관한 규명, 응용 소자에 따른 특성 평가가 필요하다. 이러한 소자 특성은 그래핀 물성에 의한 영향이 기본적이지만 에칭, 전사 등의 공정 중 발생하는 오염, 표면 특성, 잔여물 등에 의한 물성 변화 또한 분석 및 제어에 관한 연구가 필요하다. 열화학증착법(thermal chemical vapor deposition)을 이용한 그래핀 합성은 구리 기판을 사용하며, 합성된 그래핀의 에칭, 박리 및 전사 공정이 있다. 이러한 공정 중 발생하는 오염 입자가 그래핀 표면에 흡착되거나, 제거되지 않은 PMMA 잔여물이 그래핀의 특성에 영향을 미치게 된다. 따라서 본 연구에서는 $CO_2$ 클러스터의 표면 충돌을 이용하여 이러한 오염 물질 및 잔여물을 제거하고 그래핀 표면을 평탄화하는 것에 관한 연구를 수행하였다. 가스 클러스터란 작동기체의 분자가 수십에서 수백 개 뭉쳐 있는 형태를 뜻하며 이렇게 형성된 클러스터는 수 nm 크기를 형성하게 된다. 그리고 짧은 시간의 응축에 의해 수십 nm 크기 까지 성장 하게 된다. 클러스터를 이용한 표면 처리는 충돌에 의한 제거에 기반 한다. 따라서 생성 및 가속되는 클러스터로부터 대상으로 전달되는 운동량의 정도가 세정 특성에 영향을 미치며 이는 생성되는 클러스터의 크기에 종속적이다. 생성 클러스터의 크기 분포는 분사거리, 유량, 분사 각도, 노즐 냉각 온도 등의 변수에 관한 함수이다. 본 연구에서는 이러한 변수들을 제어하여 클러스터를 이용한 그래핀 표면 처리 실험을 수행하였다. 평가는 클러스터 표면 처리 전과 후의 특성 비교에 기반 하였으며, 광학 현미경을 이용한 표면 형상 측정, 라만분광 분석, AFM을 이용한 표면 조도 측정, 그래핀 면저항 측정 결과를 비교하였다. 평가 결과를 통하여 표면 처리를 하지 않은 그래핀에 비하여 면저항과 표면 조도가 낮아지는 것을 확인 할 수 있었다. 또한 클러스터 세정은 300 mm 웨이퍼 크기 이상의 대면적을 짧은 시간에 건식으로 세정할 수 있다는 장점이 있어 향후 최적화를 통해 그래핀 양산 시 특성 향상을 위한 후처리 방법으로 사용될 수 있음을 확인하였다.

  • PDF

A Study on the Corrosion Inhibitor Test Method in Acqueous Solutions (부식억제제의 부식억제능 측정법에 대한 연구)

  • 원덕수;김영근;이성민;고영태;박용수
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.45-45
    • /
    • 1999
  • 일반 구조용 탄소강은 수용액 중에 노출될 때 부식에 의한 손상을 받기 쉽다. 부식의 양지를 위한 방법으로 사용 매체 중에 부식억제제를 첨가하여 탄소강의 부식속도를 낮추는 방법은 흔히 사용되는 방법이다. 부식억제제는 부식억제의 원리에 따라 양극부식억제제, 음극부식억제제 그리 고 이들의 혼합부삭억 세제 둥 여러 종류가 목적에 따라 사용되고 있다. 일반적으로 부식억제제의 성능 평가에는 무게감량볍, 표면분석법, 분극거동측정, 부석전위, 선 형분극법에 의한 부식속도 측정 등 다양한 방법이 시도되고 있다. 이 중에서 전기화학적 평가볍 은 부삭억제제의 작용 기구 규명 등을 위하여 많이 사용되고 있다. 한편 제품의 개발 단계에서 실질적인 평가법으로 갈리 사용하고 있는 방법은 무게 감량법인데 이 방법은 전면부식에 의한 금 속 손실량을 측정하여 부식억제능을 측정하는 방법이다. 그러냐 실제로 부삭억제제가 사용되고 있는 환경에서의 부식양상을 판찰하여보면 전면부식에 의한 손상보다는 국부부식에 의한 손상이 보다 치명적언 경우를 종종 목격할 수 있다. 이러한 관점에서 가존의 무게감량법은 한계가 있다. 따라서 본 연구에서는 이러한 국부부식을 보다 효과적으로 평가하기 위해 새로운 시험법을 도 입 상용 부식억제제의 종류별로 비교하였다. 부식억제제로는 수용액 중의 부식억제제로 널리 사용되고 있는 Nalco 39L과 본 연구실에서 SK해미칼과 공동 개발한 GH-110 등에 대하여 MCA(Multiple Crevice Assembly)를 이용 틈부식 저항성을 평가하였다. 또한 박막화된 전기저항형 부석속도 측정 센서를 틈부식 형태의 부식측정 에 적용하는 연구를 행하였다. 시험에 사용한 재갚는 천연가스의 감압 온도보상용으로 운전하는 가스히터의 주 구성 재료인 저탄소강을 사용하였으며 열화된 부식억제제 용액으로 사용기간이 서로 다른 수용액들에 대하여 평가 방법을 적용하여 비교하였다 다양한 부식억 제 제 수용액을 비교한 결과 MCA(Multiple Crevice Assembly)를 이용한 틈부식 억제능 시험은 실제 현장 사험 결과와 어느 정도 일치하는 결과를 보였다. 새로운 틈부식 저항성 측정법으로 시도한 철박막을 이용 틈부식 측정법은 육안 검사를 실시하지 않고도 틈부식의 전행 여부를 확인할 수 있는 가능성을 확인하였다.

  • PDF