• Title/Summary/Keyword: 강도계수변화율

Search Result 122, Processing Time 0.037 seconds

Relationship between Compressive Strength and Dynamic Modulus of Elasticity in the Cement Based Solid Product for Consolidating Disposal of Medium-Low Level Radioactive Waste (중·저준위 방사성 폐기물 처리용 시멘트 고화체의 압축강도와 동탄성계수의 관계)

  • Kim, Jin-Man;Jeong, Ji-Yong;Choi, Ji-Ho;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.321-329
    • /
    • 2013
  • Recently, the medium-low level radioactive waste from nuclear power plant must be transported from temporary storage to the final repository. Medium-low level radioactive waste, which is composed mainly of the liquid ion exchange resin, has been consolidated with cementitious material in the plastic or iron container. Since cementitious material is brittle, it would generate cracks by impact load during transportation, signifying leakage of radioactive ray. In order to design the safety transporting equipment, there is a need to check the compressive strength of the current waste. However, because it is impossible to measure strength by direct method due to leakage of radioactive ray, we will estimate the strength indirectly by the dynamic modulus of elasticity. Therefore, it must be identified the relationship between of strength and dynamic modulus of elasticity. According to the waste acceptance criteria, the compressive strength of cement based solid is defined as more than 3.44 MPa (500 psi). Compressive strength of the present solid is likely to be significantly higher than this baseline because of continuous hydration of cement during long period. On this background, we have tried to produce the specimens of the 28 day's compressive strength of 3 to 30 MPa having the same material composition as the solid product for the medium-low level radioactive waste, and analyze the relationship between the strength and the dynamic modulus of elasticity. By controling the addition rates of AE agent, we made the mixture containing the ion exchange resin and showing the target compressive strength (3~30 MPa). The dynamic modulus of elasticity of this mixtures is 4.1~10.2 GPa, about 20 GPa lower in the equivalent compressive strength level than that of ordinary concrete, and increasing the discrepancy according to increase strength. The compressive strength and the dynamic modulus of elasticity show the liner relationship.

Effect of Free Stream Turbulence Intensity on Heat/Mass Transfer Characteristics Around a Film Cooling Hole (주유동의 난류강도가 막냉각홀 주위의 열/물질전달 특성에 미치는 영향)

  • 이동호;김병기;조형희
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.56-63
    • /
    • 1998
  • The present study investigated local heat transfer characteristics around a film cooling hole with variations of free stream turbulence intensity The film cooling jet is injected through a single hole inclined at $30^{\cire}$ to the surface and laterally at $45^{\cire}$ for the blowing rates of 0.5, 1.0 and 2.0. Turbulence generating grids are used at upstream of the film cooling hole to change the turbulence intensity of free stream. Free stream turbulence intensity without grids is 0.5%. Two different turbulence generating grid is installed at different at locations upstream of the film cooling hole so that turbulence intensity of free stream varies from 3% to 10%. The naphthalene sublimation technique has been employed to determine local heat/ mass transfer coefficients. With low free stream turbulence intensity, heat/mass transfer augmented area by coolant or free stream is distinguished evidently. However, when free stream turbulence intensity is high, heat transfer is enhanced in all region and heat transfer enhanced regions are not clearly divided due to vigorous mixing of coolant and free stream. The peak values of heat/mass coefficients are decreased and the distributions of heat/mass transfer coefficients are more uniform with high turbulence intensity. The effect of turbulence intensity on heat transfer characteristics is more evident as blowing rate is higher.

  • PDF

Effect of Aggregate on Mechanical Properties of Ultra-High Strength Concrete Exposed to High Temperature (고온을 받은 초고강도 콘크리트의 역학적 특성에 관한 골재의 영향)

  • Kim, Young-Sun;Choi, Hyoung-Gil;Ohmiya, Yoshifumi;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.431-440
    • /
    • 2011
  • Concrete structures exposed to fire produce changes in their internal structure, resulting in their service life reduction due to the deterioration of its strength and performance capacity. The deterioration level are dependent on the temperature, exposure time, concrete mix proportions, aggregate property, and material properties. This study was performed to evaluate the thermal behavior of ultra-high strength concrete for the parameters of water to cement ratio (compressive strength), fine to total aggregate ratio, and maximum coarse aggregate size. At room temperature and $500^{\circ}C$, tests of ultrasonic pulse velocity, resonance frequency, static modulus of elasticity, and compressive strength are performed using ${\varnothing}100{\times}200\;mm$ cylindrical concrete specimens. The results showed that the residual mechanical properties of ultra-high strength concrete heated to $500^{\circ}C$ is influenced by variation of a water to binder ratio, fine to total aggregate ratio, and maximum coarse aggregate size.

Characteristics of Compressive Strength and Drying-shrinkage Equation of Alkali-activated Mortar (알칼리 활성화 결합재 모르타르의 압축강도 특성 및 건조수축 추정식에 관한 연구)

  • Park, Kwang-Min;Kim, Hyung-Suk;Cho, Young-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.114-121
    • /
    • 2017
  • The purpose of this study is to understand a compressive strength and propose a dry shrinkage strain equation being able to predict dry shrinkage of alkali-activated materials(AAM) mortar samples manufactured using fly-ash(FA) and ground granulated blast furnace slag(GGBFS). The main parameters investigated were the GGBFS replace ratios(30, 50, 70 and 100%) and sodium silicate modules(Ms[$SiO_2/Na_2O$] 1.0, 1.5 and 2.0). The compressive strength of AAM increased with increases GGBFS replace ratios or Ms contents. The dry shrinkage strain of AAM decreased with increases Ms contents. But, the dry shrinkage strain of AAM increased as the GGBFS replace ratio increases. Therefore, the GGBFS replace ratio seems to have very significant and important consequences for the mix design of the AAM mortar. The results indicated the R-square of single regression analysis based on each mix properties was the highest value; 0.7539~0.9786(average 0.9359). And the presumption equation of dry shrinkage strain with all variables(GGBFS, Ms and material age) has higher accuracy and its R-square was 0.8020 at initial curing temperature 23 degrees Celsius and 0.8018 at initial curuing temperature 70 degrees Celsius.

An Experimental Study of Permeable Concrete Pavement for Application (투수성 콘크리트포장의 실용화를 위한 실험적 연구)

  • 문한영;김성수;정호섭
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.3
    • /
    • pp.165-173
    • /
    • 1998
  • 투수성 콘크리트포장은 우천시 도로포장 노면의 배수, 차량 주행 안전성의 향상 및 소음의 저감등을 목적으로 개발된 포장이지만 주행환경 및 도로주변과의 환경조화에도 기여한다. 일반적인 배수성 아스팔트 콘크리트포장에서는 투수계수 1$\times$10-2cm/sec를 목표로 정하고 있으나 본 연구에서는 투수성 콘크리트포장의 실용화를 위한 연구의 일환으로 투수계수1$\times$10-1cm/sec를 목표로 정하여 골재의 최대치수, 잔골재율 및 단위시멘트량을 변화시킨 투수성 콘크리트의 공극률, 연속공극률 및 투수계수와 제강도를 측정한 결과에 대하여 고찰하였다. 투수성 콘크리트의 목표투수계수 1$\times$10-1cm/sec 일 때 공극률 및 연속공극률은 각각 15 %와 12%정도이며, 압축강도는 240kg/$\textrm{cm}^2$정도의값을 나타내었으며, 골재의 최대치수가 10~13mm일 경우, 잔골재율 10~20%, 단위시멘트량 380 kg/$\textrm{cm}^2$정도가 적절한 배합으로 생각된다.

A Study on the Correlation Evaluation of Confining Pressure and Pile-Soil Interface Strength Reduction Factor Using Numerical Analysis (수치해석에 의한 지중 구속압과 말뚝-지반 경계면 강도감소계수 관계 분석)

  • Tae-Gyeom Lee;Jung-Geun Han;Gigwon Hong;Seung-Kyong You
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • In order to evaluate the relationship between the ground confining pressure and the shear characteristics of the pile-soil interface, this study described the comparative results of the existing experimental results and the FEA results using the strength reduction factor. The strength reduction factor was applied to simulate the shear behavior of the pile-soil interface in finite element analysis(FEA). The analysis results showed that the maximum pullout resistance decreased due to the influence of low confining pressure, as the fines content increased. This trend was similar to the previous experimental research, and this FEA model simulated with the interface strength reduction factor was evaluated as reasonable. The analysis results of the variation in the interface strength reduction factor clearly showed that the interface strength reduction factor clearly increased at a high fines content when the confining pressure was 50kPa. However, it was found that the increase rate was low when the confining pressure was 100kPa and 150kPa. Therefore, confining pressure and fines content need to be considered in FEA to evaluate the shear behavior of the pile-soil interface.

Evaluation on Fire Test for the Concrete Filled Steel Tube Column -Fire Damage Evaluation on Steel Tube and Concrete after a Fire Test- (콘크리트충전 강관기둥의 내화실험에 대한 고찰 -재하가열실험후의 강관 및 콘크리트 화재손상평가를 중심으로-)

  • Park, Ki-Chang;Choi, Sung-Mo;Kim, Dong-Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.759-767
    • /
    • 2000
  • In this study, the time dependent internal stress changes of a Concrete Filled Steel Tube(CFT) column during a fire test were quantitatively analyzed. The strain ratio of a CFT column on the different loads was measured by tensile strength tests in terms of yield strength, tensile strength average extensibility and elasticity modulus. To understand the internal material properties change of concrete in CFT column damaged due to a fire, the compressive strength and elastic modulus tests were measured on a core sample from the center of the steel tube after the fire test. The elastic modulus test measured the strain from the stress. To determine the fire temperature of the test material, a differential thermal analysis was done. From the tested result, the gained data were conducted and an analysis method was suggested. The purpose of this work is to suggest a basic data for structure regulation enactments of the internal fire design of CFT.

  • PDF

A Study of Connection Stability for Reinforced Retaining Wall Constructed with Soilbag with Varying Connection Strength (연결강도 변화에 의한 Soilbag 보강토 옹벽 연결부의 안정성 평가)

  • Lee, Sang-Moon;Choi, Changho;Shin, Eun-Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.1
    • /
    • pp.101-107
    • /
    • 2013
  • Environmental-friendly and economical construction are the recent issues for civil structures and soilbag as facing wall is widely used for cut-slope remediation projects. However, the stability of structures is an important issue for the use of environmental-friendly and economical materials. In order to understand the stability of soilbag reinforced retaining wall, tensile resistance, rupture, tensile strength, and internal/external safety factor of the wall were analyzed with MSEW program and the results were compared to the safety factor of block-type reinforced walls. The stability of retaining wall was analyzed with reduction coefficients of connection strength to check the connection stability. Because it is possible to move between soilbag and geogrid connector for soilbag retaining wall, the safety factor of the wall was analyzed with different inclination angles of soilbag. The analysis result shows that the connection strength and internal/external stability of soilbag reinforced wall satisfy the stability criteria.

Assessment of a Slope Stability of Unsaturated Soils (불포화 자연사면의 안정성 평가)

  • Ryu, Chi-Hyob;Kim, Sang-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.773-778
    • /
    • 2002
  • 강우시 불포화 자연사면의 파괴메커니즘을 규명하기 위하여 사면내 모관흡수력의 변화를 고려한 안정해석을 수행하였다. 사면에는 강우계, Tensiometer, Pizometer, Water mock, 경사계 등이 설치되었으며 강우시 사면내 부간극수압과 임시지하수위의 거동을 관찰하였다. 실내실험으로부터 불포화 사면의 안정해석을 위하여 입력 값으로 사용되는 불포화투수계수, 불포화강도정수를 시료의 No.200체 통과량과 건조밀도를 기준으로 경험계수를 이용하여 추정 사용하였다. 강우의 침투로 인한 사면내 부간극수압의 분포는 계측값과 수치해석결과가 차이를 보였으며 이는 불포화 흐름시 흙속의 공기의 영향, 강우의 나무와 수풀에 의한 중간차단효과 및 증발의 영향을 해석에 고려하지 못했기 때문으로 사료된다. 사면안정해석결과 강우초기 모관흡수력을 고려하는 경우 약 10%의 안전율의 증가를 나타냈으며, 침투가 진행되면서 그 차이는 좁아져 임시지하수위가 표층까지 도달했을 때 흡수력을 고려하지 않는 해석과 안전율은 일치하였다.

  • PDF

Effects of recycling on the mechanical properties and the surface topography of Nickel-Titanium alloy wires (재생 과정이 니켈-티타늄 호선의 물리적 성질과 표면 거칠기에 미치는 영향)

  • Lee, Sung-Ho;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.453-465
    • /
    • 2000
  • The purpose of this study was to investigate the change of mechanical properties, surface topography and frictional force of various nickel titanium wires after recycling. Three types of nickel-titanium wires and one type of stainless steel wire were divided to three groups: as-received condition(T0:control group), treated in artificial saliva for four weeks(T1) and autoclaved after being treated in artificial saliva(T2). Some changes were observed for the selected mechanical properties in tensile test, surface topography by means of SEM and 3D profilogram, and frictional coefficient. The findings suggest that: 1. Nickel-titanium wires demonstrated no statistically significant differences in maximum tensile strength, elongation rate and modulus of elasticity, but stainless steel wire demonstrated statistically significant differences in maximum tensile strength, elongation rate and modulus of elasticity between the groups(p<0.05). 2. NiTi, Optimalloy, Stainless Steel wires demonstrated increased pitting and corrosion in SEM finding. 3. Recycled NiTi, Optimalloy and stainless steel wires demonstrated significantly greater surface roughness(Ra and Rq) through 3D profilogram when compared with the control wires(p<0.05), but Sentalloy didn't demonstrate significant difference. 4. Recycled NiTi, Optimalloy and stainless steel wires demonstrated significantly greater maximum frictional coefficient when compared with the control wires(p<0.05), but Sentalloy didn't demonstrate significant difference The changes of surface roughness and frictional coefficient in NiTi and Optimalloy had no clinical implication. Consequently recycled nickel titanium wires demonstrated no clinical problem in tensile properties, surface topography and frictional coefficient.

  • PDF