• Title/Summary/Keyword: 강구조 설계

Search Result 658, Processing Time 0.022 seconds

Advaced analysis and optimal design of steel arch bridges (강아치교의 고등해석과 최적설계)

  • Choi, Se Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.13-21
    • /
    • 2005
  • Advanced analysis and optimal design of steel arch bridges is presented. In the design method using an advanced analysis, separate member capacity checks after analysis are not required because the stability and strength of the structural system and its component members can be rigorously treated in the analysis. The geometric nonlinearity is considered by using the stability function. The Column Research Council tangent modulus is used to account for gradual yielding due to residual stresses. A parabolic function is used to represent the transition from elastic to zero stiffness associated with a developing hinge. An optimization technique used is a modified section increment method. The member with the largest unit value evaluated by AASHTO-LRFD interaction equation is replaced one by one with an adjacent larger member selected in the database. The objective function is taken as the weight of the steel arch bridge and the constraint functions account for load-carrying capacities and deflection requirements. Member sizes determined by the proposed method are compared with those given by other approaches.

An Analytical Study for the Strength of the High Tension Bolted Joints in Plate Girder (Plate Girder 볼트 이음부 강도에 관한 해석적 연구)

  • Ham, Jun-Su;Hwang, Won-Sup;Yang, Sung-Don;Chung, Jee-Seung
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.469-478
    • /
    • 2012
  • In this study, structural behavior of high tension bolted connections was analyzed in order to investigate effective utilizations. Also, the simplified numerical analysis method showing bolt behavior was proposed using the connector element in the ABAQUS, a nonlinear finite element program and verified by numerical analyses on the basis of the experiment of previous study. In an effort to analyze strength properties of plate girder which high tension bolts are applied to, the effects of each design parameter were compared and analyzed after moment-displacement relations were investigated according to design parameters (upper flange, lower flange, upper and lower flange, web) by action force standards.

Test and Analysis on the Longitudinal Gusset Plate Connection to Circular Hollow Section (CHS) of High Strength (고강도 원형강관의 길이방향 거셋플레이트 접합부 실험 및 해석)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Lee, Hee-Du;Kim, Woo-Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.35-46
    • /
    • 2012
  • With the increase in the demand for high-rise buildings, the use of high-strength steel has likewise increased. Thus, it has become more necessary to study the resistance force of the high-strength hollow structural section (HSS) joint of 600MPa. Additionally, the current design equation in Korea limits maximum yield stress at 360MPa in the case of HSS. In other words, since the current specification does not apply to HSS of 600MPa, this study aims to investigate the applicability of design equations as well as examine the behavior of the connection through the experiment and finite element analysis (FEA) of the plate-tube connection of 600MPa. In particular, this paper presents the behavior of joints with the gusset plates welded in the longitudinal direction of the circular hollow section (CHS) when the joints are subjected to lateral force. Comparing design equations with the results of FEA and the test, existing design equations are underestimated to be 56~79% in the case of high-strength materials.

An Experimental Study on the Placed Steel-Plate Cell Method for Construction of Seawall (호안조성용 거치식 강판셀공법의 실험적 연구)

  • Park, Yong Myung;Oh, Sung Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.249-257
    • /
    • 1997
  • This study will present the experimental research on the establishment of design considerations and structural integrity of the placed steel-plate cell methods for seawall and waterbreak, which have some benefits in the aspects of construction cost, time and equipments compared with the existing methods. The behavior of steel-plate cell structure is complicate due to stiffeners and cell-arc junction. There is also an ambiguity on lateral pressure by cell and arc filler. To resolve such problems, full scale cell $(D11.0^m{\times}H14.0^m{\times}12t)$ has been designed and fabricated, then placed on the seabed and filled. The strain measurement has also been performed to build up the design technology together with numerical analysis.

  • PDF

Prediction of Temperature Distribution to Evaluate Axial Strength of Unprotected Concrete-filled Steel Tubular Columns under Fire (화재 시 무피복 CFT 기둥의 축강도 평가를 위한 단면온도분포 예측기법의 개발)

  • Koo, Cheol Hoe;Lee, Cheol Ho;Ahn, Jae Kwon
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.6
    • /
    • pp.587-599
    • /
    • 2013
  • A simple but accurate analytical method to evaluate the fire resistance of unprotected concrete filled tubular (CFT) columns under standard fire condition is proposed based on the fire design framework of EC4. To this end, the accuracy of the current tabulation method for the temperature prediction proposed by Lawson et al. was first critically evaluated, and a new prediction equation for the temperature gradient across the CFT section was then proposed based on available test and finite element analysis results. Overall, the axial strength predicted by using the proposed equation under the general fire design framework of EC4 was more accurate than that based on existing methods and appeared reasonable for design purposes. The results of this study are directly usable for the more rational fire analysis and design of unprotected CFT columns.

A Study of Dynamis Force Estimation and Strength Design of KALES (포장가속시험시설의 동역학 힘 예측 및 강도설계에 관한 연구)

  • Kim, Nak-In;Yang, Sung-Chul;Park, Yong-Geol
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.211-221
    • /
    • 2001
  • The dynamic force estimation and strength design of KALES(Korea Accelerated Loading and Environmental Simulator) are studied. The KALES is continuously rotating the test track and subjected to the dynamic or impact forces during operation since the track is composed of straight and curved line. To estimate the dynamic equation for the model car which was already made is derived with analytical and experimental techniques. Using similarity relationships between the model car and KALES, the dynamic force and stability properties for KALES can be predicted. The stress analysis and fatigue life estimation of KALES is also estimated with the calculated dynamic load. From the stress analysis and fatigue life estimation results, it was found that the design of KALES is safe.

  • PDF

Comparison of Wind Load Provisions Based on the Wind Buckling Behaviors of Plant Tank (플랜트 탱크의 좌굴 거동에 근거한 풍하중 설계기준 비교 연구)

  • Bae, Doobyong;Park, Il Gyu;Park, Jang Ho;Oh, Chang Kook
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.203-211
    • /
    • 2016
  • There are no consistent wind load provisions to design the plant tank in Korea. To suggest the appropriate design wind load, five kinds of specifications including KS B 6283, API 650, ASCE 7-10, EN 1991-1-4 are compared. To evaluate the adequacy of wind load specification in each code first, pressure coefficients were calculated in each code and compared with the results of wind tunnel test. Finite element analyses using linear bifurcation analysis were performed with the parameter of h/d and f/d (h : height of cylinderical part of tank, f : roof heigh, d : diameter of tank). By analyzing the results, appropriate wind load criteria which reflects the real wind actions and easy to apply will be suggested.

A Study on the Pull-out Strength of Bond Type Anchors (부착식 앵커의 인발강도에 관한 연구)

  • Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.2
    • /
    • pp.105-114
    • /
    • 2018
  • The use of post installed anchors with bond type has lately been increasing when it is necessary to repair, reinforce, or remodel structures. This method provides flexibility and simplicity for construction of structural members that require adhering or fixing. Meanwhile, strength evaluation of anchors with expansion type among post-installed anchors systems has nearly reached setting up stage like design code through continual experimental studies for the last ten years, but analyses or experimental studies on anchor system with bond type are not yet sufficient. Accordingly, the designers and builders of korea depend on foreign design codes since there are no exact domestic design code they could credit. In this study, the objectives are investigating the effects on pull-out strength of resin anchors embedded into plain concrete by pull-out experiment of resin anchors with variables such as anchor diameter, anchor interval, embedment depth and edge distance.

Design of Longitudinal prestress of precast decks in twin-girder continuous composite bridges (강박스거더 교량의 프레임 형식 중간다이아프램의 설계)

  • Yoon, Dong Yong;An, Sung Hyun;Lee, Sung Chul
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.515-524
    • /
    • 2006
  • Cross-sectional distortions take place when steel box girders a re subjected to torsional moment, as a consequence of which distortional warping stresses are necessarily developed. Additional normal stresses due to the distortion are should be included at the design stage. The relative magnitude with respect to the maximum bending stress are kept less than the specific values, i.e., at 5~10%, by properly spaced intermediate diaphragms that could prevent the distortional deformation of the box girder. However, current design equations for the stiffness of intermediate diaphragms were derived based on BEF. In this study, the area required by the intermediate diaphragm members are investigated through three-dimensional finite element analyses. The results of the analyses indicate that the current equations give to conservative values for the intermediate diaphragm of box girder bridges. Finally, an improved equation for the area of the intermediate diaphragm is derived from a regression analysis from the finite element analysis results.

Design of longitudinal prestress of precast decks in twin-girder continuous composite bridges (2거더 연속강합성 교량의 프리캐스트 바닥판 종방향 프리스트레스 설계)

  • Shim, Chang Su;Kim, Hyun Ho;Ha, Tae Yul;Jeon, Seung Min
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.633-642
    • /
    • 2006
  • Serviceability design is required to control the cracking at the joint of precast decks with longitudinal prestress in continuous composite bridges. Details of twin-girder bridges are especially complex not only due to their main reinforcements and transverse prestresses for the design of long-span concrete slabs, but also due to the shear pockets for obtaining the composite action. This paper suggests the design guidelines for the magnitude of the effective prestress and for the selection of filling materials and their requirements that would allow for the use of precast decks for twin-girder continuous composite bridges. The necessary initial prestress was also evaluated through long-term behavior analysis. From the analysis, existing design examples were revised and their effectiveness was estimated. When a filling material with a bonding strength higher than the requirement is used in the region of a high negative moment, a uniform configuration of the longitudinal prestressing steels along thewhole span length of continuous composite bridges can be achieved, which would result in the simplification of the details and the reduction of the construction costs.