• Title/Summary/Keyword: 강건위치제어

Search Result 43, Processing Time 0.019 seconds

Active and Passive Suppression of Composite Panel Flutter Using Piezoceramics with Shunt Circuits (션트회로에 연결된 압전세라믹을 이용한 복합재료 패널 플리터의 능동 및 수동 제어)

  • 문성환;김승조
    • Composites Research
    • /
    • v.13 no.5
    • /
    • pp.50-59
    • /
    • 2000
  • In this paper, two methods to suppress flutter of the composite panel are examined. First, in the active control method, a controller based on the linear optimal control theory is designed and control input voltage is applied on the actuators and a PZT is used as actuator. Second, a new technique, passive suppression scheme, is suggested for suppression of the nonlinear panel flutter. In the passive suppression scheme, a shunt circuit which consists of inductor-resistor is used to increase damping of the system and as a result the flutter can be attenuated. A passive damping technology, which is believed to be more robust suppression system in practical operation, requires very little or no electrical power and additional apparatuses such as sensor system and controller are not needed. To achieve the great actuating force/damping effect, the optimal shape and location of the actuators are determined by using genetic algorithms. The governing equations are derived by using extended Hamilton's principle. They are based on the nonlinear von Karman strain-displacement relationship for the panel structure and quasi-steady first-order piston theory for the supersonic airflow. The discretized finite element equations are obtained by using 4-node conforming plate element. A modal reduction is performed to the finite element equations in order to suppress the panel flutter effectively and nonlinear-coupled modal equations are obtained. Numerical suppression results, which are based on the reduced nonlinear modal equations, are presented in time domain by using Newmark nonlinear time integration method.

  • PDF

The Efficient Error Resilient Entropy Coding for Robust Transmission of Compressed Images (압축 영상의 강건한 전송을 위한 효과적인 에러 내성 엔트로피 부호화)

  • Cho, Seong-Hwan;Kim, Eung-Sung;Kim, Jeong-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.2
    • /
    • pp.206-212
    • /
    • 2006
  • Many image and video compression algorithms work by splitting the input image into blocks and producing variable-length coded bits for each block data. If variable-length coded data are transmitted consecutively, then the resulting coder is highly sensitive to channel errors. Therefore, most image and video techniques for providing some protection to the stream against channel errors usually involve adding a controlled amount of redundancy back into the stream. Such redundancy might take the form of resynchronization markers, which enable the decoder to restart the decoding process from the known state, in the event of transmission errors. The Error Resilient Entropy Code (EREC) is a well known method which can regain synchronization without any redundant information to convert from variable-length code to fixed-length code. This paper proposes an enhancement to EREC, which greatly improves its transmission ability for the compressed image quality without any redundant bits in the event of errors. The simulation result shows that the both objective and subjective quality of transmitted image is enhanced compared with the existing EREC at the same BER(Bit Error Rate).

  • PDF

Frequency Detection Algorithm related Variable Data Sampling and Noise (가변 데이터 샘플링과 잡음을 고려한 주파수 추적 알고리즘)

  • Lim, Young-Bin;Ham, Sung-Sik;Shin, Chul-Ho;Kim, Young- Geun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.223-224
    • /
    • 2015
  • 배전 계통 산업 현장에서는 스위칭 소자 및 제어장치, 전 자기기들이 한 대 맞물려 증가하고 있다. 또한, 스마트 그리드(Smart Grid) 및 마이크로 그리드(Micro Grid)의 개념이 도입되면서 분산 전원 이 널리 보급되고 있다. 이로 인해 현장에서는 많은 전기전자기기들이 설치되어 운영 중에 있고, 이것은 noise 및 고조파와 같은 왜란이 발생 되는 원인을 초래하고 있다. 왜란은 여러 전기 전자 장비들의 데이터 취득 왜곡 현상을 발생시키고, 이러한 데이터 손실로 인해 기기들의 오동작 및 사고를 발생시킨다. 대표적인 왜란으로는 common mode noise 같은 대지(大地) 등의 기준점과 각 신호선 사이에 나타나는 노이즈가 있으며, 선로 및 장비 특성에 따라 기수 및 우수 고조파가 있다. 이러한 왜란들은 전자기기들의 오동작 및 신호의 부 정확성으로 제품 신뢰성에 문제를 초래한다. 특히 데이터 계측 실패 및 Serial 통신을 함에 있어서 신호 손실을 발생시켜 데이터 변형을 초래한다. 이로 인해 배전선로에 위치한 전자기기들이 왜곡된 데이터로 동작을 하게 되고 이는 곧 선로의 사고를 발생시키게 된다. 따라서 왜란들을 사전에 방지하여 기기 오동작 및 부동작을 예방하기 위해서 산업계에서는 왜란에 대한 인식을 지속적으로 증가시키고 있다. 실제 현장에서도 이와 같은 왜란으로 인해 기기 오동작을 하는 경우가 많으며 이를 해결하기 위한 여러 신호처리 기법을 적용하고 있다. 이에 본 논문에서는 여러 종류의 샘플링 데이터 량을 생성할 수 있도록 샘플링 속도를 다변환(Multi-interchange)하고 각 샘플링 속도에 맞게 계측된 샘플링 데이터를 DFT 신호 처리하여 왜란으로부터 강건한 계통 주파수를 계측한다. 또한, 주파수 별 DFT 값을 Table화 하여 계통 주파수를 찾아낸다.

  • PDF