• Title/Summary/Keyword: 값 조정 인자

Search Result 56, Processing Time 0.029 seconds

Adaptive Filter Design for Eliminating Baseline Wandering Noise of Electrocardiogram (심전도 기저선 흔들림 잡음 제거를 위한 적응형 필터 설계)

  • Choi, Chul-Hyung;Rahman, MD Saifur;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • The Journal of Korean Institute of Information Technology
    • /
    • v.15 no.12
    • /
    • pp.157-164
    • /
    • 2017
  • Mobile ECG signal measurement is a technique to measure small signals of several mV, and many studies have been conducted to remove noise including wandering scheme. Removal of the equipotential line noise caused by shaking or movement of the electrode cable is one of the core research contents for the electrocardiogram measurement. In this study, we proposed a modified step-size of combined NLMS(normalized least squares) and DLMS(delayed least squares) adaptive filter to eliminate baseline noise from ECG signals. The proposed method mainly adjusts initial filter step-size to reduce distortion of original ECG signals characteristic after eliminating baseline noise. The modified filter step-size is scaled by filter order size and distortion minimization factor. This method is suitable for portable ECG device with a small processor and less power consumption. This technique also decreases computation time which is essential for real-time filtering. The proposed filter also increase the signal to noise ratio (SNR) compared to conventional NLMS filter.

Establishment of Optimal Management Plans on Agricultural Groundwater Resources of the Yeosu County (여수시 농어촌지역 지하수자원 적정 관리방안)

  • Seo, Hyo Kyoung;Shin, Hyung Jin;Lee, Byung Sun;Lee, Gyu Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.282-282
    • /
    • 2020
  • 본 연구는 여수시 농어촌지역에 대하여 지하수 함양특성, 개발가능량 산정 및 오염부하량 등의 조사를 통해서 체계적인 지하수자원의 보전관리(안)을 수립하기 위해 수행되었다. 연구지역은 여수시 화양면, 소라면 2개 면을 포함하는 농어촌 용수구역(여소지구)으로, 여소지구의 총면적은 130.68 ㎢이며, 이 중 임야면적은 81.57 ㎢, 경지면적은 32.98 ㎢ 이고, 경지면적은 논 15.37 ㎢, 밭 17.42 ㎢, 시설재배 0.19 ㎢로 구성되어 있다. 여소지구의 30년 강수평균은 1,454.08 mm/년이며, 지하수 함양량은 국가지하수관리 기본계획(국토교통부, 2019) 및 전라남도 지하수관리계획(전라남도, 2009) 보고서를 참고하여 평균값인 11.28%로 산정한 결과, 21,279 천㎥/년으로 분석되었다. 또한, 지하수연보(국토교통부, 2018)의 세부용도별 이용량을 활용하여 지하수 이용량을 산정한 결과, 2,638.35 천㎥/년이었으며, 강수량, 함양률 및 면적 값을 고려하여 지하수 개발가능량을 산정한 결과, 16,387.57 천㎥/년, 개발가능량 대비 이용량은 16.11%로 확인되었다. 여소지구의 질산성질소 항목은 총 181개소(경지면적 0.2 ㎢당 1점)에 대해 분석한 결과, 전체 평균값은 6.67 mg/L이었으며, 농업용수 수질기준(20 mg/L)을 초과한 관정은 8개소(6%)로 확인되었다. DRASTIC을 이용한 오염취약성 지수는 평균값이 119.57점으로 나타나 오염취약성이 낮은 것으로 분석되었다. 신고·허가된 축사 시설을 기준으로 점오염원 조사결과, 단위면적당 시설수(오염원밀도)는 3.12 개소/㎢로 조사되었으며, 인구, 가축 및 토지이용 등 인자별을 고려하여 오염부하량을 산출한 결과, 단위면적당 오염부하량은 75.30 kg/day/㎢로 확인되었다. 행정구역별로 7가지 지표를 반영하여 관심, 주의, 경계 및 심각 4단계로 기준을 설정하여 지하수관리 필요지역을 선정하였다. 수량 측면은 개발가능량 대비 이용량, 단위면적당 이용량 및 관정밀 3가지 지표를 적용하였고, 수질 측면은 질산성질소 평균, 오염취약성 지수, 오염원밀도 및 단위면적당 오염부하량 4가지 지표를 적용하여 선정하였다. 지하수관리 필요지역을 분석한 결과, 전체 18개 리 중에서 14개 리에서 수량관리 12개리에서 수질관리 필요지역이 나타났다. 수량관리 필요지역은 지하수 취수량 조정 및 관리 확충 등의 대책방안이 마련되어야 하며, 수질관리 필요지역은 주변 오염원관리 및 수질검사 강화 등의 대책방안이 필요할 것으로 판단된다.

  • PDF

Role of Radiation Therapy for Stage III Thymoma (제 3기 흉선종에서 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.16-20
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of the postoperative radiation therapy for patients with Stage III thymoma and to define the optimal radiotherapeutic regimen Materials and Methods : We retrospectively analyzed the records of 24 patients with Stage III thymoma who were referred for postoperative radiation therapy in our institution from June, 1987 to May, 1999. Surgical therapy consisted of total resection in one patient, subtotal resection in seventeen, and biopsy alone in six patients. Age of the patients was ranged from 20 to 62 years with mean age of 47 years. Male to female ratio was 14 to 10. Radiation therapy was delivered with linear accelerator producing either 6 MeV or 10 MeV photons. The irradiated volume included anterior mediastinum and known residual disease. The supraclavicular fossae were not irradiated. The delivered total dose was ranged from 30 to 56 Gy. One patient received 30 Gy and eighteen patients received minimum of 50 Gy. Follow up period was ranged from 12 months to 8 years with median follow up of 40 months. Results : The overall local control rate for entire group of patients was $67\%$ at 5 years. The cumulative local failure rates at one, three and five year were $18\%,\;28\%\;and\;33\%$, respectively. In patients treated with subtotal resection and biopsy alone, local control rate was $76\%\;and\;33\%$, respectively. The actuarial observed survival rate at 5 years was $57\%$, and actuarial adjusted survival at 5 years was $72\%$. The difference between 5 year survival rates for patients treated with subtotal resection and biopsy alone was not statistically significant $(62\%\;vs\;30\%)$. Conclusion : We might conclude that postoperative radiation therapy was safe and effective treatment for patients with Stage III thymoma. Postoperative radiation therapy is recommended in cases where tumor margin is close or incomplete resection is accomplished.

  • PDF

Effects of Some Physico-Chemical Conditions of Sioil on Growth and Ionic Balance of the Tobacco Plant (Nicotiana Tabacum L.) I. Effect of Acidity(pH), Moisture(pF) and Anions (Cl-, SO4-) in Soil on Grwth and Ionic Balance of Tobacco (토양(土壤)의 몇가지 이화학적조건(理化學的條件)이 연초(煙草)의 생육(生育) 및 이온평형(平衡)에 미치는 영향(影響) I. 토양(土壤)의 pH, pF와 음(陰)이온(Cl-, SO4-)이 연초(煙草)의 생육(生育) 및 이온평형(平衡)에 미치는 영향(影響))

  • Kim, Jai-Jong;Cho, Seong-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.14 no.3
    • /
    • pp.117-129
    • /
    • 1981
  • An experiment with the tobacco plant was conducted in the pots. A sandy humic soil was used with 2 levels of pH, 3.5 and 5.8 with 2 kinds of anions, Cl as $NH_4Cl$ and $SO_4$ as $(NH_4)_2SO_4$, and with 4 levels of pF, 1.5, 2.0, 2.5, and 3.5. The pH-treatment created different N-forms; $NH_4$ at low pH(3.5) and $NO_3$ at high pH (5.8). The results are summarized as follows: 1. At low pH (3.5) with high concentration of $NH_4$ given as $NH_4Cl$, the high content of $NH_4$ and Cl in tobacco resulted in plants suffering from $NH_4$ and Cl toxicity as well as Mn toxicity. As a result of these toxicity, an extremly abnormal growth of tobacco was clearly appeared. In the tobacco grown at low pH with $NH_4$ given as $(NH_4)_2SO_4$, a large amount of the $NH_4$ uptake developed Mg and Ca deficiencies. $NH_4-N$, which had been applied to the soil of high pH (5.8), was almost completely transformed into $NO_3-N$ by nitrification and, on this low acidic soil, the plants were all healthy regardless of Cl or $SO_4$ added together with $NH_4-N$. However, dry matter production was higher and maturity faster when $SO_4$ was used as anion than when Cl was used. 2. High moisture content in soil, to some extent, is necessary for a good development and growth of the tobacco plant. Phosphate uptake seemed to be limited at higher moisture stress. The dry matter yield of tops and roots of tobacco were in the order of pF 1.8 > 2.1 > 2.6 > 3.6, respectively. 3. Data of chemical analysis and dry matter yields of tops and roots showed that the tobacco plant followed the normal (C-A) concept. In the normal growth of plants, the carboxylate content of tops was quite comparable to the estimated (C-A) values. If $NH_4$ content of plants remains in quite high quantities, it must be analysed and taken into consideration for the (C-A) calculation. Al is not transported toward tops in toxic amounts due to its high immobility, it mostly stay in or on the roots, probably due to precipitation as a aolt. When Al is present in high quantities, it has to be considered into the (C-A) calculation.

  • PDF

Habitat Quality Analysis and Evaluation of InVEST Model Using QGIS - Conducted in 21 National Parks of Korea - (QGIS를 이용한 InVEST 모델 서식지질 분석 및 평가 - 21개 국립공원을 대상으로 -)

  • Jang, Jung-Eun;Kwon, Hye-Yeon;Shin, Hae-seon;Lee, Sang-Cheol;Yu, Byeong-hyeok;Jang, Jin;Choi, Song-Hyun
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.1
    • /
    • pp.102-111
    • /
    • 2022
  • Among protected areas, National Parks are rich in biodiversity, and the benefits of ecosystem services provided to human are higher than the others. Ecosystem service evaluation is being used to manage the value of national parks based on objective and scientific data. Ecosystem services are classified into four services: supporting, provisioning, regulating and cultural. The purpose of this study is to evaluate habitat quality among supporting services. Habitat Quality Model of InVEST was used to analyze. The coefficients of sensitivity and habitat initial value were reset by reflecting prior studies and the actual conditions of protected areas. Habitat quality of 21 national parks except Hallasan National Park was analyzed and mapped. The value of habitat quality was evaluated to be between 0 and 1, and the closer it is to 1, the more natural it is. As a result of habitat quality analysis, Seoraksan and Taebaeksan National Parks (0.90), Jirisan and Odaesan National Parks (0.89), and Sobaeksan National Park (0.88) were found to be the highest in the order. As a result of comparing the area and habitat quality of 18 national parks except for coastal-marine national parks, the larger the area, the higher the overall habitat quality. Comparing the value of habitat quality of each zone, the value of habitat quality was high in the order of the park nature preservation zone, the park nature environmental zone, the park cultural heritage zone, and the park village zone. Considering both the analysis of habitat quality and the legal regulations for each zone of use, it is judged that the more artificial acts are restricted, the higher the habitat quality. This study is meaningful in analyzing habitat quality of 21 National Parks by readjusting the parameters according to the situation of protected areas in Korea. It is expected to be easy to intuitively understand through accurate data and mapping, and will be useful in making policy decisions regarding the development and preservation of protected areas in the future.

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF