• Title/Summary/Keyword: 감전사고

Search Result 94, Processing Time 0.033 seconds

A Study on Electric-technical Regulation of Handhole Structure and Insulation for Preventing Electrical Shock Accident (감전사고 예방을 위한 지중함 구조 및 절연 관련 시설기준 개발에 관한 연구)

  • Kim, Gi-Hyun;Cha, Song-Hee;Son, Yi-Jo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1303-1308
    • /
    • 2017
  • The underground electricity distributions are significantly increased because of the urbanization accompanied by rural area developments. However, it has also been increased the safety accidents such as an electric shock around the handhole where the underground cables are connected to each other. This paper provides the base materials on the necessity to amend the installation regulation for securing the insulation and structure strength of handholds using the cast iron or fiberglass reinforced plastic. Article 137 in the judgement regulation for the Korea electro-technical regulation which is one of the installation regulations for handhole is amended and announced in 2017 by being based on the materials in this paper. It is expected to continually reduce the electric shock occurrence around handhole by considering the amended installation regulation.

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

Anti-islanding Detection using Frequency Drift of Grid-connected PV PCS Analysis (계통 연계형 태양광 발전 시스템의 주파수 변동을 통한 단독운전 검출 기법 분석)

  • Jo, Yeong-Min;Choi, Ju-Yeop;Choy, Ick;Lee, Young-Kwon;Cho, Sang-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.52-53
    • /
    • 2014
  • 계통이 차단되었음에도 태양광 발전 시스템이 발전을 지속하는 상황을 단독운전이라 하는데, 이런 단독운전은 배전 설비의 손상, 선로 유지 및 보수자의 감전사고 우려가 있으므로 이를 신속히 인지하여 시스템을 정지시켜야 한다. 본 논문에서는 최악의 상황에서도 단독운전 현상을 신속히 검출하여 시스템을 정지시킬 수 있도록 주파수 변동을 통한 단독운전 검출 기법에 대하여 새롭게 제안하고, 이를 시뮬레이션과 실험을 통해 단독운전 검출 성능 및 정상 상태 시 PCS 출력 전력의 품질에 대하여 분석하도록 한다.

  • PDF

The Application Method of a Protection Conductor for the Prevention of Electric Shock in England (감전사고 예방을 위한 영국의 보호도체 적용 방법)

  • Jung, Jin-Soo;Jung, Jong-Wook;Han, Woon-Ki;Lee, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2216-2217
    • /
    • 2008
  • This paper write about earth system for the prevention electric shock and a protection of equipment in england. The IEC60364 and BSI(British Standards Institution) define earthing method(IT, TT, TN-C, TN-S, TN-C-S)-BSI is british standards and in case of england almost use the TN system. TN system can classify TN-S & TN-C-S(PME). The findings on survey in england are used the TN-S system and TN-C-S system about 70% and residue 30% are used TT system and IT system from the exiting state of things.

  • PDF

A Statistical Analysis on the Electric Shocks in 2014 (2014년 감전사고 통계 분석)

  • Hong, Eun-Hee
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.171-179
    • /
    • 2015
  • As the industrial scale is getting enlarged and the people's quality of life is growing, the electric energy consumption has been rapidly increasing every year and the frequency of electrical accidents such as electrical shock This paper gives statistical analysis of the number of casualties caused by the electrical shock, five hundred people every year, but it still exceeded the shaping risk of electrical accidents to anyone in KOREA. In this paper, for the electrical shock of the in 2014 act by occupation, voltage electrical equipment, location, accident type and months. In order to acquire electrical shock in 2014, we visited police stations and hospitals and analyzed records of accidents. The result showed that the electrical shock alone caused 37 people deaths and 569 injuries.

The Tools Development for Electric Shock Accident Prevention at Electric Construction Work (전기공사 작업시 감전사고 방지용 공구류 개발)

  • Lee, H.K.;Kim, H.J.;Baek, S.H.;Won, S.H.;Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.43-45
    • /
    • 2005
  • Electric accidents, like getting electrified, sometimes happen to people working on electricity. A highly probable reason why these electric accidents happen is that workers are used to skip confirming disconnection of electricity when they work. It is mostly because they have little understanding of electricity. To overcome this, various applications such as 'electric detecting stick' are invented to check existence of electricity on working environment. But, they have not been popular due to inconvenience of carrying. So, we made a new instrument. It is a kind of nipper on which electric detecter is installed. Detecting existence of electricity is less burdensome via this tool we made.

  • PDF