Regional Distribution of Isotropy Magnetic Property of Dual-type Giant Magnetoresistance-Spin Valve Multilayer (이중구조 거대자기저항-스핀밸브 박막의 자기등방성 영역분포에 관한 연구)

  • Khajidmaa, Purevdorj;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.193-199
    • /
    • 2013
  • The regional distribution of magnetic isotropy depending on the post annealing condition for the dual-type structure GMR-SV (giant magnetoresistance-spin valve) of NiFe/Cu/NiFe/IrMn/NiFe/Cu/NiFe multilayer was investigated. The rotation of in-plane ferromagnetic layer induced by controlment of the post annealing temperature inside of the vacuum chamber. The magnetoresistive curves of a dual-type IrMn based GMR-SV depending on the direction of the magnetization easy axis of the free layer and the pinned layer are measured by between $0^{\circ}$ and $360^{\circ}$ angles for the applied fields. The optimum annealing temperature having a steady and isotropy magnetic sensitivity of 1.52 %/Oe was $107^{\circ}C$ in the rotational section of $0{\sim}90^{\circ}$. By investigating the switching process of magnetization for an arbitrary measuring direction, the in-plane orthogonal magnetization for the dual-type GMR-SV multilayer can be used by a high sensitive biosensor for detection of magnetized micro-beads.

Implementation of the Electronic Sensor System for Pedestrian Safety Based on Embedded (임베디드 기반의 보행자 안전을 위한 전자감응시스템 구현)

  • Ryu, Seung-Han;Park, Sung-Won;Moon, Geon-Hee;Jung, Hoe-kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1825-1830
    • /
    • 2015
  • In some cases, despite the pedestrian jaywalking pedestrian traffic lights to red, or even wait for the walk signal to stand down in the driveway. If this is the case may be liable to lead to a traffic accident. Thus, using an infrared sensor wateuna adopted the approach that the warning announcement when a pedestrian enters the driveway, curved pedestrian crossing the intersection in this case, it is difficult to install. In this paper, we propose a Fitness referral system utilizes a built-in sensor of the Android mobile devices. For this purpose, the sensor is a proximity sensor using an acceleration sensor. The proximity sensor has a number of disadvantages compared to the high precision battery power, the acceleration sensor accuracy, fast response time, on the other hand, the disadvantage is the lower. Close to reduce battery consumption of the sensor, BMI of the user sensor control mechanism and increase the accuracy of the acceleration sensor (Body Mass Index) obtained after the index was applied to the recommendation algorithm, which like the movement mechanism.

Determination of carbaryl in aqueous solution by fluorescence spectrometry (형광분광법을 이용한 수용액 중의 carbaryl의 정량)

  • Kim, Wook Hyun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.307-312
    • /
    • 2009
  • A spectrofluorimetric methods has been developed for the determination of carbaryl in an aqueous solution. The effects of excitation wavelength, concentration of surfactant, concentration of ethanol as cosurfactant and emission wavelength on the fluorescence intensity were investigated to find the optimum experimental conditions to determine carbaryl. The emission intensity of the carbayl was increased with addition of sodium dodecyl sulfate (SDS) as a surfactant. The emission intensity of the carbaryl was further increased with addition of ethanol as a co-surfactant. The optimum conditions were 281 nm for excitation wavelength, $1.0{\times}10^{-2}mol/L$ SDS, 20% (v/v) ethanol and 349 nm for emission wavelength. Under the optimum conditions, the emission intensity increased with the carbaryl concentration in the range of $5{\times}10^{-7}$ to $1.0{\times}10^{-4}mol/L$ with a detection limit ($3{\sigma}$) of $1.1{\times}10^{-8}mol/L$. The resulting correlation coefficient of the working curve was 0.9996.

${\beta}-Ag_3SI$ Single Crystal Membrane Electrode (${\beta}-Ag_3SI$ 단결정막 전극에 관한 연구)

  • Sin Doo-Soon;Seon-Cheon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.86-94
    • /
    • 1984
  • The single crystal ion-selective electrode,$ {\beta}-Ag_3SI/PVC-THF $membrane electrode has showed a linear potential response to the activities of iodide ion (10-1${\sim}$10-7M). The $ {\beta}-Ag_3SI$ membrane electrode was compared with AgI/PVC-THF membrane and copper metal plate membrane electrodes. In order to measure the selectivity coefficient of the electrodes toward $Cl^-$ and $Br^-$, the separation and mixed solution method were employed. The potential-time curve was obtained by the usual immersion technique and pH effect was also examined. The orders of selectivity for $Br^-$, $Cl^-$ and stability of response time are ${\beta}-Ag_3SI/PVC-THF $membrane > AgI/PVC-THF membrane > copper metal plate membrane. These electrodes could be used as indicating electrodes in the potentiometric titration of a single halide and mixed halides with the standard solution of silver nitrate.

  • PDF

Determination of Residual Concentration and Half-life Time in Soils of Imidazole Fungicide Prochloraz (Imidazole계 살균제 Prochloraz의 토양 중 잔류량과 반감기분석)

  • Choi, Yong Hwa;Han, Seong Soo;Kim, Il Kwang
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.67-71
    • /
    • 2002
  • The residual analysis and half-life time of imidazole fungicide prochloraz in soils (silty clay) were investigated by gas chromatography equipped electron capture detector (GC-ECD). The soil samples were extracted acetone/hexane(1:1) solvent and analyzed after separated by $LC-NH_2$ Sep-Pak solid column. Linear sensitivity of standard calibration curve was Y = 268.8600X + 0.0664, $R^2=0.9998$ between 0.05~1.00 ng. The detection limit was 0.02 mg/L and the average recoveries were 94.5~97.3% from the standard additional experiments with 0.10 and 0.40 mg/L. The half-life time was 24.4 days in room laboratory and 7.6 days in the field test soil.

Determination of Eu(III) by Fluorescence Spectrometry using Fiber Optic Sensor (광섬유센서를 이용한 Eu(III)의 형광분광법적 정량)

  • Lee, Sang Hak;Lee, Yoon Hee;Yang, Seung Tae;Choi, Sang Seob
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.409-412
    • /
    • 1998
  • The analytical method to determine europium(III) ion in aqueous solution by fluorescence spectroscopy based upon the conformational change of calmodulin in the presence of the analyte has been studied. The fiber optic chemical sensor used in this study was constructed by entrapping a fluorescein-labeled calmodulin solution, EGTA, buffer solution at the common end of a bifurcated fiber optic bundle by means of a dialysis membrane. The calibration curve to determine europium(III) ion was obtained when concentration of calmodulin, concentration of EGTA, Tris-HCl buffer solution, pH, excitation wavelength and fluorescence wavelength were $5.0{\times}10^{-5}M$, 0.50 mM, 5.0 mM, 7.0, 495 nm and 520 nm, respectively. The detection limit was $1.0{\times}10^{-11}M$ and the working range of the calibration curve for the sensor was $1.0{\times}10^{-11}M{\sim}1.0{\times}10^{-9}M$. The response time was 15 minutes. For the determination of europium(III) ion by the present method, $Na^+$ and $K^+$ ions did not interfere but $Ca^{2+}$ ion seriously interfered.

  • PDF

Fabrication of $TiO_2$ Electrode Containing Scattering Particles in Dye-Sensitized Solar Cells (산란 입자를 포함하는 염료감응 태양전지용 $TiO_2$ 전극 제조)

  • Lee, Jin-Hyoung;Lee, Tae-Kun;Kim, Cheol-Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.57-62
    • /
    • 2011
  • The energy conversion efficiency of DSSCs (Dye-Sensitized Solar Cells) is dependent on the powder size, the structure, and the morphology of $TiO_2$ electrode. The higher efficiency is obtained with high surface area of the nanoanatase-$TiO_2$ powder adsorbed onto a lot more of the dye. Also, the enhancement of light scattering increases the efficiency with high adsorption of the dye. Powder size, crystalline phase, and shape of $TiO_2$ obtained by hydrothermal method have 15-20 nm, anatase and round. $TiO_2$ electrode has fabricated with the mixture of scattering $TiO_2$ particle with 0.4 ${\mu}m$ in nano-sized powder. Conversion efficiency of series of DSSCs was measured with volume fraction of scattering particle. Photovoltaic characteristics of DSSCs with 10% scattering particles are 3.51 mA for Jsc (short circuit current), 0.79 V for Voc(open circuit potential), filling factor 0.619 and 6.86% for efficiency. Jsc was improved by 11% and enhancement of efficiency by 0.77% compared with that of no scattering particles. The confinement of inserted light by light scattering particles has more increase of the injection of exiton(electron-hole pair) and decrease of moving path in electron. Efficiencies of DSSCs with more than 10% for scattering particles have reduced with increasing the pore in the $TiO_2$ electrode.

The characteristics of dye-sensitized solar cells using carbon nanotube in working and counter electrodes (작업전극과 상대전극에 탄소나노튜브를 이용한 염료감응 태양전지의 특성연구)

  • Kim, Bora;Song, Suil;Lee, Hak Soo;Cho, Namjun
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.308-313
    • /
    • 2014
  • The effect of electrochemical characteristics of dye-sensitized solar cells (DSSC) upon employing multi-wall carbon nanotube (MWCNT) on both working electrode and counter electrode were examined with using EIS, J-V curves and UV-Vis absorption spectrometry. When 0.1 wt% of MWCNT was employed in the $TiO_2$-MWCNT composit on working electrode, the energy conversion efficiency increased about 12.5% compared to the $TiO_2$ only working electrode. The higher light conversion efficiency may attribut to the high electrical conductivity of MWCNT in $TiO_2$-MWCNT composite which improves the electron transport in the working electrode. However, higher amount of MWCNT than 0.1 wt% in the $TiO_2$-MWCNT composite decreases the light conversion efficiency, which is mainly ascribed to the decreased transmittance of light by MWCNT and to the decreased adsorption of dye onto $TiO_2$. The MWCNT employed counter electrode exhibited much lower light conversion efficiency of DSSC than the Pt-counter electrode, while the MWCNT-Pt counter electrode showed similar in light conversion efficiency to that of Pt-counter electrode.

Design and Evaluation of a Microcomputer-based Vacuum Drying System for Shiitake Mushrooms (마이크로컴퓨터 시스템을 이용한 표고버섯의 감압건조에 대한 연구)

  • Choi, Jae-Yong;Kim, Kong-Hwan;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.550-555
    • /
    • 1987
  • Strain gauges attached on the Bourdon tube and load cell were used as the sensors for measuring the vacuum pressure in drying chamber and the weight loss of Shiitake mushrooms respectively. The vacuum drying system was interfaced further with the Bear II microcomputer. The interface devices used were built with such IC chips as MC 6821, ADC 0809, SN 74244 and SN 7424. The relationship between readings of vacuum gauge (P, mmHg) and digital outputs (D) from the microcomputer was represented by P =3.08 D-13.4875(r=0.9999). The weights of drying sample (W) were also related with the digital outputs (D) by W=0.4076 D-6.4762 (r=0.9999). During the vacuum drying of Shiitake mushrooms. the data on pressure and weight were recorded at regular intervals using an acquisition program on the microcomputer system. The Page model was fitted well to the drying data of Shiitake mushrooms. resulting in the following empirical equations : $(M-M_e)/(M_o-M_e)=\exp(-0.1569t^{1.0048})$ at 400 mm Hg up to 14 hours and $(M-M_e)/(M_o-M_e)=\exp(-0.1385_t^{1.2688})$ at 600 mm Hg up to 8 hours.

  • PDF

Determination of L-Dopa by Spectrofluorimetry Using Co-fluorescence Enhancer (보조 형광증가제를 이용한 L-Dopa의 형광분광법적 정량)

  • Lee, Sang Hak;Ahn, Jung Mi
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.541-546
    • /
    • 2000
  • Methods to determine L-dopa(L-3,4-dihydroxyphenylalanine) in aqueous solution by spectrofluorimetry based upon the ligand sensitized luminescence of Tb(III) ion L-dopa complex have been studied. Tb(III) ion and Lu(III) ion were used as ligand sensitized fluorescencer and co-fluorescence enhancer, respectively. The effects of excitation wavelength, pH, concentration of Tb(III) ion, concentration of Lu(III) ion and emission wavelength on the fluorescence intensity were investigated. The fluorescence intensity of the Tb(III) ion L-dopa complex was further increased with addition of Lu(III) ion. The calibration curve for L-dopa was linear over the range from 5.0 ${\times}$ $10^{-7}$ M to 1.0${\times}$ $10^{-4}$ M and the detection limit was 4.0 ${\times}$ $10^{-8}$ M under the optimal experimental conditions of 300 nm, 8.0, 1.0 ${\times}$ $10^{-4}$ M and 545 nm for excitation wavelength, pH, concentration of Tb(III) ion and emission wavelength, respectively. When Lu(III) ion was added to Tb(Ⅲ) ion L-dopa complex, the concentration range of linear response and detection limit were 1.0${\times}$$10^{-8}$ M to 2.0 ${\times}$ $10^{-4}$ M and 1.0 ${\times}$ $10^{-9}$ M, respectively under the optimal experimental conditions of 300 nm, 8.5, 1.0 ${\times}$ $10^{-5}$ M, 1.0 ${\times}$ $10^{-5}$ M, 545 nm for excitation wavelength, pH, concentration of Tb(III) ion, concentration of Lu(III) ion and emission wavelength, respectively.

  • PDF