• Title/Summary/Keyword: 감쇠 최소 자승법

Search Result 28, Processing Time 0.02 seconds

Determination of Shallow Velocity-Interface Model by Pseudo Full Waveform Inversion (유사파형역산에 의한 천부의 속도-경계면 모델 결정)

  • Jeong, Sang Yong;Shin, Chang Soo;Yang, Seung Jin
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.481-485
    • /
    • 1995
  • This paper presents a new approaching method to determine the velocity and geometry of shallow subsurface from seismic refraction events. After picking the first breaks from seismic refraction data, we assume that field refraction seismogram can be replaced by the unit delta function having time shift of first break. Time curves are generated by shooting ray tracing. The partial derivatives seismogram for a damped least squares method is computed analytically at each step of the forward ray tracing. The technique is successfully tested on synthetic and real data. It has the advantage of real full waveform inversion, which is robust at low frequency band even if the initial guess is far from the true model.

  • PDF

A Study on Semi-active Vibration Isolation Table using a Nonlinear Analysis of the MR Damper (MR 댐퍼의 비선형해석을 이용한 반능동형 제진대에 관한 연구)

  • Kim, DoYoung;Chun, ChongKeun;Kwon, YoungChul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.11
    • /
    • pp.861-867
    • /
    • 2014
  • In this study, a semi-active isolator was constructed from applying a MR damper that used the MR fluid to an isolator. The parameter identification was also performed to determine the characteristics of this semi-active isolator during which the least squares method and the auxiliary variable method were applied to produce a value closest to the true value. In addition, the MR damper's nonlinear damping force was closely analyzed to greatly reduce the range of error. Based on this analysis, it was discovered that the parameter tended to increase with more electric current. Such analysis of the dynamic properties of semi-active isolator proved that constructing an isolator that provides a more stable operation could be achieved.

Long Term Monitoring of Dynamic Characteristics of a Jacket-Type Offshore Structure Using Dynamic Tilt Responses and Tidal Effects on Modal Properties (동적 경사 응답을 이용한 재킷식 해양구조물의 장기 동특성 모니터링 및 조류 영향 분석)

  • Yi, Jin-Hak;Park, Jin-Soon;Han, Sang-Hun;Lee, Kwang-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.97-108
    • /
    • 2012
  • Dynamic responses were measured using long-term monitoring system for Uldolmok tidal current pilot power plant which is one of jacket-type offshore structures. Among the dynamic quantities, the tilt angle was chosen because the low frequency response components can be precisely measured by dynamic tiltmeter, and the natural frequencies and modal damping ratio were successfully identified using proposed LS-FDD (least squared frequency domain decomposition) method. And the effects of tidal height and tidal current velocity on the variation of natural frequencies and modal damping ratios were investigated in time and frequency domain. Also the non-parametric models were tested to model the relationship between tidal conditions and modal properties such as natural frequencies and damping ratios.

Nonlinear elements position detecting by error matrix method (오차행렬에 의한 비선형 요소 위치 파악에 관한 연구)

  • 변언섭;이상설;박윤식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1104-1111
    • /
    • 1990
  • A method to identify nonlinear elements position of a nonlinear system is presented. Nonlinear elements position can be identified by an equivalent error damping and stiffness matrices which are based on the equivalent linearization technique. The procedures of this technique are: (1) Obtain input force and system response. (2) Define error between the actual and linearized restoring forces. (3) Calculate linearized damping and stiffness coefficients to minimize the square error sum. Several examples are tested and found that these methods are very effective not only to locate the nonlinear elements position but also to identify the degree of nonlinearity qualitatively. Nonlinear type can be qualitatively identified by examining the plots of restoring force vs equivalent state values.

Ground Vibration Tests of SmartUAV Airframe Structure (스마트무인기 기체구조물 지상진동시험)

  • Jeon, Byoung-Hee;Kang, Hui-Won;Lee, Jung-Jin;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.482-489
    • /
    • 2010
  • This paper describes the test procedure, instrumentation, verification methodology and the results of the ground vibration test(GVT) and force vibration test(FVT) of the SmartUAV aircraft to estimate experimentally dynamic characteristics of the aircraft. Bungee cords are used to emulate free-free boundary conditions of the test aircraft. The SmartUAV is excited by three shakers and one-hundred frequency response functions(FRF's) is measured. The FRF's are reduced and analyzed to identify the dynamics parameters of the SmartUAV. To extract modal parameters of the SmartUAV such as, natural frequencies and damping ratios, the poly-reference least square complex exponential method is used in the time domain. The mode shape coefficients are estimated with the least squares frequency domain method to identify the vibration modes. The FVT was performed by fixed sine frequency with three shakers on the x, y and z direction and vibration characteristics of structures and detail equipments are measured.

On the vibration influence to the running power plant facilities when the foundation excavated of the cautious blasting works. (노천굴착에서 발파진동의 크기를 감량 시키기 위한 정밀파실험식)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.9 no.1
    • /
    • pp.3-13
    • /
    • 1991
  • The cautious blasting works had been used with emulsion explosion electric M/S delay caps. Drill depth was from 3m to 6m with Crawler Drill ${\phi}70mm$ on the calcalious sand stone (soft -modelate -semi hard Rock). The total numbers of test blast were 88. Scale distance were induced 15.52-60.32. It was applied to propagation Law in blasting vibration as follows. Propagtion Law in Blasting Vibration $V=K(\frac{D}{W^b})^n$ were V : Peak partical velocity(cm/sec) D : Distance between explosion and recording sites(m) W : Maximum charge per delay-period of eight milliseconds or more (kg) K : Ground transmission constant, empirically determind on the Rocks, Explosive and drilling pattern ets. b : Charge exponents n : Reduced exponents where the quantity $\frac{D}{W^b}$ is known as the scale distance. Above equation is worked by the U.S Bureau of Mines to determine peak particle velocity. The propagation Law can be catagorized in three groups. Cubic root Scaling charge per delay Square root Scaling of charge per delay Site-specific Scaling of charge Per delay Plots of peak particle velocity versus distoance were made on log-log coordinates. The data are grouped by test and P.P.V. The linear grouping of the data permits their representation by an equation of the form ; $V=K(\frac{D}{W^{\frac{1}{3}})^{-n}$ The value of K(41 or 124) and n(1.41 or 1.66) were determined for each set of data by the method of least squores. Statistical tests showed that a common slope, n, could be used for all data of a given components. Charge and reduction exponents carried out by multiple regressional analysis. It's divided into under loom over loom distance because the frequency is verified by the distance from blast site. Empirical equation of cautious blasting vibration is as follows. Over 30m ------- under l00m ${\cdots\cdots\cdots}{\;}41(D/sqrt[2]{W})^{-1.41}{\;}{\cdots\cdots\cdots\cdots\cdots}{\;}A$ Over 100m ${\cdots\cdots\cdots\cdots\cdots}{\;}121(D/sqrt[3]{W})^{-1.66}{\;}{\cdots\cdots\cdots\cdots\cdots}{\;}B$ where ; V is peak particle velocity In cm / sec D is distance in m and W, maximLlm charge weight per day in kg K value on the above equation has to be more specified for further understaring about the effect of explosives, Rock strength. And Drilling pattern on the vibration levels, it is necessary to carry out more tests.

  • PDF

Multiple Lapse Time Window Analysis using Focal Mechanism (진원함수를 고려한 다중지연시간창 해석)

  • Chung, Tae-Woong;Yoshimoto, Kazuo
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.2
    • /
    • pp.85-91
    • /
    • 2012
  • Multiple Lapse Time Window (MLTW) analysis for obtaining intrinsic attenuation value require numerous data without directional bias to compensate focal mechanism. The first window of MLTW, therefore, shows large deviation in fitting smoothed theoretical curve. The information on the focal mechanism may reduce burdens of number and distribution. This study combined algorithm of computing focal mechanism to DSMC method by Yoshimoto (2000). However, the MLTW method based on the numerous data was not applicable to this study, because of the limited data to the almost same fault plane solution. This study showed that the available data was too insufficient to construct smoothed theoretical curve, although the deviation of the first window was improved. Instead of conventional solution by more data, the study seems to be needed for new constraints to obtain smoothed curve.

Development of the HEMP Generation, Propagation Analysis, and Optimal Shelter Design Tool (고 고도 전자기파(HEMP) 발생과 전파해석 및 방호실 최적 설계 Tool 개발)

  • Kim, Dong Il;Min, Gyeong Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2331-2338
    • /
    • 2014
  • The HEMP threat may have acquired new, and urgent, relevance as the proliferation of nuclear weapons and missile technology accelerates of the North Korea, for example, is assessed as already having developed few atomic weapons, and is on the verge of North Korea already has missiles capable of delivering a nuclear warhead against South Korea. ITU K.78, K81 and IEC recommended its counter-measuring for the industrial facilities with navigation and sailing facilities in order to obviate the all of processor equipped system malfunctions from the EMP/HEMP but its simulation must only be done by the computer simulation which had studied on the 1960-1990 years USA/AFWL papers. This result has a significant activities to the South Korea being under the North Korea threat because all of HEMP related products was strongly limited for export. The HEMP cord which was developed newly by the KTI including the HEMP generation & propagation analysis, optimal shelter design tool, essential EM energy attenuation in multi-layered various soils and rocks and HEMP filter design tool. Especially, the least square fitting method was adopted to analysis for the EM energy attenuation in the soils and rocks because it has a various characteristics based on the many times field test reports.