• Title/Summary/Keyword: 감쇠식

Search Result 349, Processing Time 0.026 seconds

Attenuation Relations in HAZUS for Earthquake Loss Estimations in Korea (한반도 지진재해예측을 위한 HAZUS의 강진동 감쇠식 비교연구)

  • Kang, Su-Young;Suk, Bong-Chool;Yoo, Hai-Soo;Kim, Kwang-Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.6
    • /
    • pp.15-21
    • /
    • 2007
  • Strong motion attenuation relationship represents a comprehensive trend of ground shakings at sites with distances from the source, geology, local soil conditions, and others. It is necessary to develop an attenuation relationship with careful considerations of characteristics of the target area for reliable seismic hazard/risk assessments. In the study, observed ground motions from the January 2007 magnitude 4.9 Odaesan earthquake and the events occurring in the Gyeongsang provinces are compared with the previously proposed ground attenuation relationships in the Korean Peninsula to select most appropriate one. In the meantime, a few strong ground motion attenuation relationships are proposed and introduced in HAZUS, which have been designed for the Western United States and the Central and Eastern United States. The selected relationship from the ones for the Korean Peninsula has been compared with attenuation relationships available in HAZUS. Results of the study will increase the reliability of seismic hazard/risk assessments using HAZUS in the Korean Peninsula.

충격식 감쇠기의 감쇠특성에 관한 연구

  • 김원철;전순기;양보석;문덕홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.285-290
    • /
    • 1992
  • 기계 구조물의 과도한 진동은 기계의 성능 및 수명에 나쁜 영향을 미치며 기계및 부품의 파괴까지 유발하게 되는 원인이되므로 이를 제진하기위한 각종 방법이 오래전부터 연구되고 있다. 본 연구에서는 현재까지 진행된 충격식 댐퍼의 이론을 기초로 한 사이클당 두번의 충돌이일어난다는 가정하에, 파라메타 의 변화에따른 최적 감쇠특성을 얻기위한 최적간극과 최적 질량비를 쉽게구할 수 있는 식을 유도하였다. 그리고, 실험에 의하여 공진상태에 있어서 불의 충격력에 의한 감쇠특성을 조사하였고, 이론으로구한 식과 비교 검토함으로서, 실제 현장등에서 간편하게 근사식을 이용하여 최적조건을 구하고, 이 자료를 기초로하여 설계, 제작시 보다 간편하게 사용할 수 있도록 하였다.

Simple Empirical Attenuation Relationship for Potential Nuclear Power Plant Sites (원자력발전소의 단순화 된 실증적 지진감쇄 관계)

  • Tanwa, Kankang;Eric, Yee
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.9
    • /
    • pp.43-49
    • /
    • 2018
  • Seismic hazard assessments are performed on a variety of infrastructure projects. One component of a seismic hazard assessment is the attenuation relationship. Several attenuation relationships have been developed over the decades to predict peak ground acceleration under a variety of site conditions. For example, many attenuation relationships were designed to estimate peak ground acceleration, as well as other intensity measures, under a variety of soil conditions, mostly using the average shear wave velocity for the upper 30 m of earth material as a classification scheme. However, certain types of infrastructure, such as tunnels and nuclear power plants, are typically founded on and in bedrock. Using data from Japan, we developed a simple correlation to estimate peak ground acceleration for rock sites and compare the results from another popular attenuation relationship. Results indicate the popular attenuation relationship to be less than the proposed model for distances less than 200 km.

Dynamic Modeling of Semi-active Squeeze Mode MR Damper for Structural Vibration Control (구조물의 진동 제어를 위한 압착식 MR 감쇠기의 동적 모델링)

  • Heo, Gwang-Hee;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.172-180
    • /
    • 2009
  • Normally in order to build a semi-active control system equipped with MR damper, the dynamic modeling of the damper is required to numerically predict its dynamic damping force and also its behavioral characteristics. For the dynamic modeling of the MR damper, this paper attempts to predict and evaluate its dynamic behavior by applying specifically both a power model and a Bingham model. Dynamic loading tests were performed on the squeeze type of damper specially designed for this research, and force-displacement hysteresis loops confirmed the effectiveness of the damper as a semi-active control device. In the meantime, in order to evaluate the effectiveness of each model applied, the model parameter for each model was identified. On the basis of the parameter, we derived the error ratio of the force-velocity relationship curve and the dynamic damping force, which was contrasted and compared with the experimental results of the squeeze type of damper. Finally, the squeeze type of MR damper developed in this research was proved to be valid as a semi-active control device, and also the evaluation of the two dynamic models showed they were working fine so that they were likely to be easily utilized to numerically predict the dynamic characteristics of any dampers with MR fluid as well as the squeeze type of MR damper.

Equivalent Damping Ratio of a SDOF Structure Combined with Coulomb and Viscous Damping (점성 및 마찰감쇠가 있는 단자유도 구조물의 등가감쇠비)

  • Seong, Ji-Young-Suck;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.449-453
    • /
    • 2010
  • 본 논문에서는 점성 및 감쇠가 있는 단자유도 구조물의 등가감쇠비를 효율적으로 구하는 방법을 제시하였다. 건물에 설치된 마찰감쇠기는 외력의 크기에 따라 정지와 운동의 상태를 반복하여 외부 입력에너지를 소산시키기 때문에 외력과 응답관계가 비선형이다. 마찰감쇠기가 설치된 단자유도 건물은 마찰감쇠기외에 점성감쇠가 동시에 존재하므로 해석적인 정해를 구하기가 어렵다. 등가감쇠비를 산정하기 위해서 첫째, 점성과 마찰감쇠가 있는 단자유도계 건물의 자유진동 정해를 통하여 변위응답과 가속도 응답특성을 분석하였다. 둘째, 자유진동의 경우 응답이 멈출 때까지 소산에너지식을 이용하여 등가점성감쇠비를 구하였다. 셋째, 조화가진 일 때는 수치해석을 통하여 마찰력비 $F_r$에 따른 응답 특성을 알아보았다. 넷째, 조화가진의 경우 에너지 균형식을 바탕으로 등가점성감쇠비를 유도하였다. 등가점성감쇠비는 변위응답비의 영향을 받으므로 응답을 알아야만 구할 수 있다. 건물 응답의 진동수 특성은 협소영역(narrow band)이므로 고유진동수에 의해 지배된다고 가정하여 등가점성감쇠비를 구하였다. 마지막으로, 유도한 자유진동과 조화가진의 등 가점성감쇠비를 이용한 등가선형운동방정식의 해를 비선형 수치해석 한 결과와 비교하여 검증하였다.

  • PDF

Seismic Response Control of Structures Using Decentralized Response-Dependent MR Dampers (분산제어식 응답의존형 MR 감쇠기를 이용한 구조물의 지진응답제어)

  • Youn, Kyung-Jo;Min, Kyung-Won;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.761-767
    • /
    • 2007
  • In centralized control system, complicated control systems including sensors, power supply and dampers should be required to satisfy the target response of large-scale structures. The practical applications of the centralized control system, however, is very difficult due to high order finite element model of structures, uncertainty of models, and limitations of the excitation system. In this study, the decentralized response-dependent MR damper of which magnetic field is automatically modulated according to the displacement or velocity transferred to the damper without any sensing and computing systems. this decentralized response-dependent MR damper are investigated according to the ranges of relative magnitude between the control force of MR damper and the story shear force of structures by nonlinear time history analysis. Finally, its performance is compared with centralized LQR algorithm which is used in general centralized control theory for a three story building structure.

Identification of Viscous and Friction Damping Using Free Vibration Response to SDOF System (단자유도계의 자유진동응답을 이용한 점성 및 마찰감쇠의 식별)

  • Lee, Sung-Kyung;Lee, Woong-Gu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.305-310
    • /
    • 2019
  • This paper proposes the method of exactly identifying both viscous and friction damping from free vibration response to SDOF structure. Both displacement and acceleration free vibration responses to SDOF system, in which both viscous and friction damping are considered as its damping mechanism, are discussed to verify the proposed method. The relationship for identifying both viscous and friction damping is derived from two consecutive amplitudes of displacement or acceleration peak response. The proposed method is verified through the numerical simulation for an assumed SDOF system consisting of mass, both viscous and friction damping and spring components.

Hydrodynamic Response Analysis of Hybrid Floating Structure according to Length of Damping Plate (수평감쇠판 길이에 따른 하이브리드 부유식 구조물의 거동 특성 분석)

  • Min Su, Park;Youn Ju, Jeong;Young Taek, Kim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.6
    • /
    • pp.275-289
    • /
    • 2022
  • New businesses such as marine leisure and floating construction have recently flourished on the coast. As a result, consideration is given to a floating structure appropriate for marine environments. In this study, we applied a damping plate to increase the stability of a hybrid floating structure that was expanded by vertical and horizontal stacking of mobile unit modules. In the numerical analysis using ANSYS AQWA, the behavioral characteristics of the floating structure were analyzed according to the length change of the damping plate. However, the wave forces acting on a floating structure are excessively calculated by the resonance of fluid surrounded by the structure in the numerical analysis using potential flow. Therefore, we used the damping zone option of the ANSYS AQWA in the frequency domain analysis.

Equivalent Linear System Considering Earthquake Characteristics of MR damper installed in a SDOF (지진하중 특성을 고려한 단자유도 구조물에 설치된 MR감쇠장치의 등가선형시스템)

  • Moon, Byoung-Wooke-Ri;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.774-777
    • /
    • 2010
  • 본 논문에서는 MR 감쇠기의 비선형 특성을 등가의 선형감쇠로 치환하기 위한 방법으로 Newmark와 Hall이 제안한 감쇠계수를 이용하였다. 응답스펙트럼의 감쇠율을 나타내는 감쇠기계수는 구조물의 최대변위를 이용하여 등가감쇠비를 추출할 수 있다는 장점을 가지고 있다. 하지만 이러한 응답스펙트럼은 구조물에 작용하는 지진하중의 특성에 따라 경향이 달라진다. 본 논문에서는 기존의 등가감쇠비 산정식을 수정하여 제안하고, 지진하중 특성에 따른 등가감쇠비의 변화를 살펴보았다. MR 감쇠기의 등가감쇠비는 가진하중과 최대마찰력의 비율에 따라 결정되며, 장주기 구조물의 경우 등가감쇠비가 감소한다. MR 감쇠기의 점성은 마찰감쇠와의 상호작용에 의해 단순한 산술합 이상의 감쇠비 증가 효과를 가진다.

  • PDF

Development of Variable Voltage Sensing for Identification of Dynamic Characteristics of TLCDs (동조액체기둥감쇠기의 동적특성을 파악하기 위한 가변전압측정 시스템 개발)

  • Jang, Seok-Jung;Kim, Jun-Hee;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.275-281
    • /
    • 2015
  • In this study, vertical motion of a Tuned Liquid Column Damper(TLCD) is measured by a variable voltage measurement system in the electric field and design parameters of the TLCD are determined. First, nonlinear damping term of the TLCD is replaced as the equivalent viscous damping term. The natural frequency and damping ratio of dynamic characteristics of the TLCD are verified. In addition, a novel liquid level measurement system is developed for measuring vertical motion of the TLCD. For the experimental achievement, experimental characterizations of natural frequency and damping ratio of the TLCD are undertaken utilizing the developed variable voltage sensing. Also, shake table testing is performed to determine the dynamic characteristics of the TLCD. As a result, the feasibility of the proposed liquid level measurement system is verified by comparison with the capacitive type wavemeter.