• Title/Summary/Keyword: 감마 방사능

Search Result 182, Processing Time 0.043 seconds

Full-digital portable radiation detection system (디지털 휴대용 방사능 검출 시스템)

  • Oh, Jae-kyun;Lee, Seok-Jae;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1436-1442
    • /
    • 2015
  • In recently the world trend of security system for shipping transport is much more important and stronger, so following the world trend, there is development to security system of shipping transport for national security logistics system construction. it is still ongoing. For the world trend of security system, there is attempt of portable radiation detection, which is possible to get detection of nuclide in south Korea.

Radiation Analysis by Chemical Treatment of Agricultural Products in Environmental Samples (환경시료 중 농산물에서 화학적 처리 방법에 의한 방사능 분석)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.531-538
    • /
    • 2017
  • Agricultural products produced in the agricultural area around the nuclear power plant are radioactive contamination, which can cause radioactive contamination to the human body. The purpose of this study was to investigate the limit of the radioactivity concentration $^{90}Sr$ for the internal exposure dose evaluation by ingesting the agricultural products collected around the nuclear power plant. The results of the gamma-isotope element analysis were freshly <0.0166-0.0336 Bq / kg for all samples and for artificial radionuclides not detected, and fresh <0.00586-0.0421 Bq / kg for Chinese cabbage, The freshness was 0.106 Bq / kg, and the freshness was 0.0114-0.0901 Bq / kg. 0.0177%, 0.0222%, 0.0376% and 0.00243%, respectively, for Chinese cabbages and large roots, which is lower than the legal standard value of $1mSv/yr{\cdot}man%$. It is considered that the formulas need to be broadly evaluated for the foods consumed by children and adults, taking into consideration the age of the food and the diet

Analysis of 226Ra in the Groundwater Using the Gamma-ray Spectroscopy (감마선 분광법을 이용한 지하수 중의 226Ra 분석)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The measurement of radium ($^{226}Ra$) in the groundwater was established using ${\gamma}$-ray spectroscopy without sample preparation. The background interference by air borne radon daughter nuclides was reduced by $N_2$ gas flow into the counting chamber. Leakage of radon gas produced in the radioactive equilibrium with radium and its daughter nuclides was prevented by use of the air-tighted aluminium container. We investigated the effect of air layer in the counting container. Radioactivity variation due to emanation of radon into the air layer was within the counting error range 5%. When the nitrogen gas was flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of airborne radon was decreased and detection limit was decreased to 0.02 Bq/L. The detection limit of detector was lower than 0.74 Bq/L, the $^{226}Ra$ Maximum Contaminant Level (MCL) in the groundwater proposed by US Environmental Protection Agency (EPA). It was confirmed that $^{226}Ra$ radioactivity in the groundwater could be determined by the ${\gamma}$-ray spectroscopy.

방사선동위원소를 이용한 밀도/수분함량 측정계기의 회로설계

  • 송정호;황주호;길경석;김기준
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.365-372
    • /
    • 1997
  • 이 연구의 목적은 밀도측정 및 수분함량측정용 RI 계기의 개발에 있다. 방사성동위원소를 이용하여 성토시공의 현장다짐 밀도 및 수분함량 측정에 이용되곤 있는 RI 계기는 중성자 검출부분, 감마선 검출부분, 고전압 공급부분, 마이크로 컴퓨터 부분으로 크게 나눌 수 있다. 감마선을 검출하는 G-M 검출기는 그 특징으로 인해 방사선검출 전기회로가 간단하다. 그러나 열중성자를 검출하는 He-3 검출기는 검출기에서 발생하는 신호원이 매우 작아서 검출회로의 상호 간섭으로 인한 전기적 잡음이 발생한다 이 잡음을 제거하는 것이 He-3 중성자 검출기로 열중성자를 검출하는데 중요한 문제이다. 본 연구에서 제작하는 RI 계기는 원자력법에서 제한하는 방사능 이하를 (100$\mu$Ci 의 밀봉선원) 사용하므로 종래의 RI 계기에 비해 방사선의 검출수가 줄어든다. 이에 따라 검출기의 개수를 늘려서 방사선을 검출해야 한다. 또한 본 연구에서는 He-3검출기의 검출 스펙트럼을 분석하여 적정한 방사선 검출 측정영역을 결정하였다.

  • PDF

Measurement of Ir-192 Source Activity for High Dose Rate Brachytherapy (고 선량률 근접치료시 사용되는 Ir-192 선원의 방사능 평가)

  • 최동락;허승재;안용찬;임도훈;김대용;우홍균
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 1997
  • Ir-192 source activity for high dose rate brachytherapy is measured using Farmertype ionization chamber. The source-to-chamber distance is 10 cm and the measured charge unit is converted to activity unit. The measured values are compared to the values provided from vendor. Because of time dependency of Ir-192 source activity, the activities are regularly checked and compared to calculated values. As the accuracy of Ir-192 source activity is depend on the mechanical measurement setup, we estimated the precision of remote controlled source dwell position using home-made device and film scanner. The difference between measured and predicted dwell position is within 1 mm. As a result, the errors of source activity are 0.7${\pm}$1.5 % for measured and vendor-provided values and 0.l${\pm}$1.2% for measured and time-dependent calculated vlaues. In conclusion, our measured activity has been comparable to the values provided from vendor and our brachytherapy unit has been very accurate until now. Regular quality control of brachytherapy is essential for successful treatment which depends on the accuracy of source position and activity.

  • PDF

Analysis of the Distributional Effects of Radioactive Materials on External Gamma Exposure (방사성물질의 분포특성에 따른 외부 감마피폭해석)

  • Han, Moon-Hee;Kim, Eun-Han;Suh, Kyung-Suk;Hwang, Won-Tae;Choi, Young-Gil
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.211-218
    • /
    • 1998
  • The distributional effects of radioactive materials on external gamma exposure have been analyzed. An approximate method for estimating external gamma dose given from an arbitrary distribution of radioactive material has been developed. The minimum gamma exposure given from a point source is shown at 0.07 MeV if the source to receptor distance is shorter than 10 m. But if the receptor to point source distance is longer than 20 m, gamma exposure rate increases monotonously according to the average gamma energy. For the analysis of the effects of volume source, we estimated the gamma dose given from different size of hemisphere in which radioactive materials are distributed uniformly. When the radius of hemisphere is longer than 40 m, external gamma dose rate increases monotonously. The gamma dose rate given from the radioactive materials deposited on the ground shows the minimum value at 0.07 MeV in any case. The analysis shows that external gamma exposure is strongly dependent on the distribution of radioactive materials in the environment and gamma energy.

  • PDF

Lung Clearance of Inhaled $^{99m}Tc$-DTPA by Urine Excretion Ratio (소변내 방사능배설량비를 이용한 $^{99m}Tc$-DTPA 폐청소율에 관한 연구)

  • Suh, G.Y.;Park, K.Y.;Jung, M.P.;Yoo, C.G.;Lee, D.S.;Kim, Y.W.;Han, S.K.;Jung, J.K.;Lee, M.C.;Shim, Y.S.;Kim, K.Y.;Han, Y.C.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.357-366
    • /
    • 1993
  • Background: Lung clearance of inhaled $^{99m}Tc$-DTPA reflects alveolar epithelial permeability and it had been reported as more sensitive than conventional pulmonary function tests in detecting lung epithelial damage. However, measuring lung clearance of inhaled $^{99m}Tc$-DTPA by gamma camera may not always reflect alveolar epithelial permeability exactly because it is influenced by mucociliary clearance depending on the site of particle deposition. Moreover, this method takes much time and patient's effort because he has to sit or lie still in front of the camera for a prolonged period. Most of the absorbed DTPA is excreted in urine within 24 hours and the amount of excreted DTPA in urine during the first few hours after inhalation is influenced by absorption rate which is correlated with the alveolar-epithelial permeability suggesting that the urinary excretion, especially in first few hours, may be an alternate index for lung clearance. The purpose of this study was to evaluate the usefulness of ratio of excreted $^{99m}Tc$-DTPA in 2 hour and 24 hour urine as an index of alveolar-epithelial damage. Methods: Pulmonary function tests including diffusing capacity and lung clearance of $^{99m}Tc$-DTPA measured by gama camera ($T_{1/2}$) and 2hr/24hr urine excretion ratio (Ratio) of inhaled $^{99m}Tc$-DTPA in 8 normal subjects and 14 patients with diffuse interstitial lung disease were compared. Results: 1) In the normal control, there was significant negative correlation between the $T_{1/2}$ and the Ratio (r=-0.77, p<0.05). In patients with diffuse interstitial lung disease, there also was significant negative correlation between $T_{1/2}$ and Ratio(r=-0.63, p<0.05). 2) In diffuse interstitial lung disease patients, the $T_{1/2}$ was $38.65{\pm}11.63$ min which was significantly lower than that of normal control, $55.53{\pm}11.15$ min and the Ratio was $52.15{\pm}10.07%$ also signifantly higher than that of the normal control, $40.43{\pm}5.53%$ (p<0.05). 3) There was no significant correlations between $T_{1/2}$ or Ratio and diffusing capactiy of lung in both patients and controls (p>0.05). Conclusion: These results suggests that 2hr/24hr urine excretion ratio of inhaled $^{99m}Tc$-DTPA is a useful simple bedside test in assessing alveolar epithelial permeability and that it may be used as an additive follow-up test in patients with diffuse interstitial lung disease complementing conventional pulmonary function tests.

  • PDF

Time Series Analysis of Gamma exposure rates in Gangneung Area (강릉 지역 공간 감마선량률의 시계열 분석)

  • Cha, Hohwan;Kim, Jaehwa
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.25-30
    • /
    • 2013
  • In this work, we investigate the statistical properties of gamma exposure rates using well-known analysis methods, such as Autocorrelation Function Analysis(ACF), Rescaled Range Analysis(R/S Analysis), and Detrended Fluctuation Analysis(DFA). Especially, DFA is an important method to reliably detect long-range correlations in non-stationary time series. Our data are measured by Gangneung regional radiation monitoring station over the period of 1998 to 2011. First, we find a crossover indicating two different governing regimes in fluctuations of gamma exposure rates. Within a year, they show a strong long-ranged memory while this property vanishes over the range of time period longer than one year. Second, our finding is very securely supported by a variety of analysis tools. Those tools yield many relevant exponents which satisfies the well known relation between them.