• Title/Summary/Keyword: 감마선 센서

Search Result 68, Processing Time 0.029 seconds

Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources (다종 감마선 공간분포 측정을 위한 고감도 검출센서 및 탐지모듈 개발)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.705-707
    • /
    • 2017
  • Stereo-based spatial radiation detection devices can obtain not only spatial distribution information about the radiation source but also distance information from the detection device to the source. And it provides more efficient information on the source than the existing radiation imaging device. In order to provide high-speed information on the spectrum and type of gamma-ray source, a high-sensitivity detection sensor with high sensitivity is required, and a technique capable of solving the saturation phenomenon at a high dose is needed. In this paper, we constructed a high sensitivity sensor for the measurement of multiple gamma - ray spatial distributions using improved function of detection module to solve saturation to high dose and conducted research to increase the scope of a single detector. The result of this paper improves the performance of gamma ray.

  • PDF

Effects of Gamma Irradiation on Array Type Fiber Bragg Grating Sensors (배열형 FBG 센서의 감마선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.937-939
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings (FBGs) manufactured by array sensors. The array FBGs were fabricated in a different Bragg wavelength using the same commercial Ge-doped fiber and exposed to gamma-radiation up to a dose of about 100 kGy at the dose rate of 113 Gy/min. It was analyzed radiation effects by measuring the radiation-induced change in the temperature sensitivity coefficient and Bragg wavelength shift after irradiation.

  • PDF

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

Radiation Effects on Fiber Bragg Gratings Written by Femtosecond Laser (펨토초 레이저로 제작된 광섬유 브래그 격자 센서의 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Im, Don-Sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.961-963
    • /
    • 2015
  • In this study, we studied the effect of $Co^{60}$ gamma-radiation on the fiber Bragg gratings written by femtosecond UV laser in single mode optical fibers. The fiber Bragg gratings were exposed to gamma-radiation up to a dose of about 31.6 kGy at the dose rate of 106 Gy/min. According to the experimental data and analysis results, we confirmed Bragg gratings written by femtosecond laser have the excellent radiation-hardened characteristics for high radiation environments.

  • PDF

금속나노입자 기능화된 산화물 나노선 센서의 감응특성

  • Choe, Seon-U;Jeong, Seong-Hyeon;Park, Jae-Yeong;Kim, Sang-Seop
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.33.2-33.2
    • /
    • 2010
  • 산화물 반도체 나노선 가스센서는 기존의 벌크 및 박막재료에 비해 체적-표면적비가 매우 커서 극미량의 화학물질에 대한 감응특성이 유리하여 많은 각광을 받고 있다. 현재, 다양한 물질들의 나노선 합성 및 센서 소자 구현에 대한 연구가 국내외적으로 활발하게 진행되고 있다. 이와 같은 나노선 센서의 실용화를 위해 특정 물질에 대한 선택성과 감응특성의 증진이 여전히 요구되고 있으며, 이에 대한 여러 방향에서의 연구가 진행되고 있다. 특히, 촉매특성이 뛰어난 귀금속 나노입자를 나노선 표면에 부착시킨, 기능화된 나노선 센서소자에 관련된 연구가 활발하다. 본 연구에서는 기상법을 이용하여 합성한 산화물 나노선에 감마선을 조사하여 Au, Pt 및 Pd 금속나노입자를 형성시켰다. 이와 같이 금속나노입자가 고착된 산화물 나노선의 미세구조와 가스 감응특성을 조사하였으며, 기능화된 금속 나노입자가 가스 감응에 미치는 영향과 가스 감응 메커니즘을 제시하고자 한다.

  • PDF

Optimized Design and Manufacture of Wideband Pulsed Gamma-ray Sensors (광대역 펄스감마선 탐지센서 최적화 설계 및 제작)

  • Jeong, Sang-hun;Lee, Nam-ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.223-228
    • /
    • 2017
  • In this paper, we are proposing an optimal design of wideband pulsed type gamma-ray sensors. These sensors were manufactured based on the design results and after word electrical properties were analyzed. The sensor input parameters were derived on the basis of pulsed gamma-ray spectrum and time-dependent energy rate, and the output current which were derived on the basis of the sensor sensitivity control circuit. Pulsed gamma-ray sensors were designed using the TCAD simulators. The design results show that the optimal Epi layer thickness is 45um with the applied voltage 3.3V and the diameter is 2.0mm. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. The fabricated sensor was a leakage current, 12pA at voltage -3.3V and fully depleted mode at voltage -5V. A test result of pulsed radiation shows that the sensor gives out the optimal photocurrent.

Gamma-radiation Effects on Fiber Bragg Gratings Written in Photo-sensitive and Commercial Single-mode Optical Fibers (광민감 광섬유와 일반 단일모드 광섬유로 제작한 브래그 격자 센서의 감마방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Im, Don-Sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.701-704
    • /
    • 2014
  • In this study, we studied the effect of $Co^{60}$ gamma-radiation on the FBGs written in photo-sensitive and commercial Ge-doped single-mode optical fibers. The FBGs were exposed to gamma-radiation up to a dose of 17.8 kGy at the dose rate of 300 Gy/min. According to the experimental data and analysis results, the lowest Bragg wavelength shift (18 pm) was obtained by a grating written in photosensitive fiber without $H_2$-loading.

  • PDF

A Study on Optimized Design of Wideband Pulsed Gamma-ray Detectors (광대역 펄스감마선 탐지센서 최적화설계에 관한 연구)

  • Jeong, Sang-hun;Lee, Nam-ho;Son, Eui-seung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1121-1124
    • /
    • 2015
  • In this paper, we propose and demonstrate an optimal design of wideband pulsed gamma-ray detectors. Pulsed gamma-ray detectors are designed to operate in a dose rate of $1{\times}10^6{\sim}1{\times}10^8rad(Si)/s$. The input parameter was derived based on the energy ratio of pulse gamma-ray spectrum and the time of the energy. The sensor output current was calculated based on the dose rate control circuit. Using the N-type Epi Wafer, the optimum condition detection sensor was designed based on TCAD. The simulation results show that the optimal Epi layer thickness is 45um when applied voltage 3.3V. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. Pulse gamma-ray detector diameter is the 1.3mm.

  • PDF

The development of th gamma-ray imaging and operation algorithm for the gamma-ray detection system (감마선 탐지장치의 감마선 영상화 및 운용 알고리즘 개발)

  • Song, Kun-young;Hwang, Young-gwan;Lee, Nam-ho;Yuk, Young-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.942-943
    • /
    • 2016
  • Stereo gamma ray detection system generates a two-dimensional image of the gamma ray by using the position values and the gamma ray signal. And the device will overlap with the visible light image shows the actual distribution of the gamma-ray space. The gamma ray detection device is a stereo configuration to a motion controller for controlling the signal measurement unit and the position detection portion for detecting the detection portion and the gamma-ray signal comprising a gamma-ray detection sensor. In this paper, we developed a system operation management algorithm for each module individually configured efficiently. We confirmed the imaged and distribution information output for the gamma rays from gamma-ray irradiation test site by using these results.

  • PDF

A Dosimeter System using a short distance radio communication (근거리 무선 통신을 이용한 선량계 구현)

  • Seo, Yong-Chil;Son, Jong-Dae;Lee, Heung-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.571-573
    • /
    • 2004
  • 본 논문에서는 휴대용 선량계 시스템에 거리 무선 통신 방식중 Bluetooth를 이용하여 선량계를 구현한 것에 대해 논하였다. 휴대용 선량계란 감마선과 속중성자 및 열중성자를 현장에서 실시간으로 측정 할 수 있는 기기이다. 휴대용 선량계는 선랑계의 소형화를 위해 모듈별로 구성하여 공간의 최적화를 취하였다. 모듈의 구성은 시스템의 전반적인 제어를 하는 CPU부 센서로부터 측정한 데이터를 처리하는 신호처리부 방사선량을 측정하는 센서부로 구성되어졌다. 센서 모들의 PIN 다이오드와 MODFET 센서를 이용하여 감마선, 속중성자, 열중성자를 측정한다. 휴대용 선량계를 관리하고 측정한 데이터의 백업 및 분석을 위하여 PC용 관리프로그램과 근거리 무선 통신(Bluetooth)을 사용하여 통신하도록 만들어 사용하였다. 측정 지역의 방사선량을 휴대용 선량계로 측정하여 PC용 관리프로그램에서 실시간으로 방사선량을 확인 할 수 있다.

  • PDF