• Title/Summary/Keyword: 감마선 검출

Search Result 292, Processing Time 0.023 seconds

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Response of LiF Thermoluminescent Dosimeter to Gamma-Rays as a Cavity Detector (LiF 열형광선량계(熱螢光線量計)의 감마선(線)에 대한 공동검출기(空洞檢出器)로서의 감응(感應))

  • Ha, C.W.;Yook, C.C.;Jun, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.10-14
    • /
    • 1976
  • Influence of the cavity size on the response of LiF TLD was theoretically investigated for a presumed system of spherical TLD cavity imbedded in a medium of polyethylene. Calculation of the response for different radii of the spherical cavity was carried out as a function of incident photon energy, applying recent cavity theory. The range of the radii covers 1.578 to 6.528 mm, while that of the incident photon energies extends from 0.02 to 3.0 MeV. As a results, the response of the LiF TLD imbedded in a medium as a cavity was found to be functions of its own size as wall as the incident photon energy.

  • PDF

A Simultaneous Determination of Chromium, Iron, Lanthanum, Scandium and Zinc in River Water by Neutron Activation (중성자 방사화에 의한 시료중의 크롬, 철, 란탄, 스칸듐 및 아연의 동시정량)

  • Lee Ihn Chong;Kim Si-Joong;Lee Chul
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.6
    • /
    • pp.427-433
    • /
    • 1977
  • A neutron activation method has been developed for the simultaneous determination of chromium, iron, lanthanum, scandium and zinc in river-water samples. The sample is sealed in the silica ampoule without pretreatment and irradiated for a week at a thermal neutron flux of $1{\times}10^{13}n{\cdot}cm^{-2}{\cdot}sec^{-1}$. After cooling for about two days, the elements in the sample are sequentially extracted at different pH by 0.1M oxine-chloroform solution. The organic layers are checked by Gamma-ray spectrometry with $″3\;{\times}\;3″$ NaI (T1) detector connected to a 800-channel pulse hight analyzer. The ppb concentration of the elements in most of river-water samples could be determined by this method. The tracer study for the quantitative separation of the elements was also carried out.

  • PDF

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Process Development of a Virally-Safe Acellular Bovine Amniotic Membrane for Biological Dressing (바이러스 안전성이 보증된 무세포 소 양막 생물창상피복재 제조 공정 개발)

  • Bae, Jung-Eun;Kim, Chang-Kyong;Kim, Sung-Po;Yang, Eun-Kyung;Kim, In-Seop
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.420-427
    • /
    • 2010
  • A process for manufacturing virally-safe bovine amniotic membrane(BAM) has been developed for biological dressing. BAM was harvested from a healthy bovine placenta, and then the epithelium was removed. The remaining stromal layer was consecutively disinfected with 70% ethanol and 0.05% sodium hypochlorite. The stromal layer was incubated in a decellularization solution containing 0.25%(w/v) trypsin to remove the cellular components. The resulting acelluar BAM was lyophilized to preserve its biochemical and structural integrity. The BAM was packed and exposed to 25 kGy of gamma irradiation for sterilization purpose. Histological, electron microscopical, and biochemical observations showed that the acellualr BAM had intact structural integrity of three dimensional collagen fibers and contained several growth factors, accelerating wound healing, such as EGF (Epidermal growth factor), KGF (Keratinocyte growth factor), and FGF (Fibroblast growth factor). Bovine herpes virus (BHV), bovine viral diarrhoea virus (BVDV), bovine parainfluenza virus type 3 (BPIV-3), and bovine parvovirus (BPV) were chosen as the biological indicators for validation of viral safety of the acellular BAM. Samples from relevant stages of the production process were spiked with each virus and subjected to viral inactivation processes. Viruses were recovered from the samples and then titrated immediately. All the viruses tested were completely inactivated to undetectable levels within 1 h of 70% ethanol treatment. Enveloped viruses such as BHV, BVDV, and BPIV-3 were more effectively inactivated than BPV by 0.05% sodium hypochlorite treatment. BHV, BVDV, and BPIV-3 were completely inactivated to undetectable levels by 25 kGy of gamma irradiation. Also BPV was effectively inactivated by 25 kGy of gamma irradiation. The cumulative log reduction factors of BHV, BVDV, BPIV-3, and BPV were ${\geq}$13.30, ${\geq}$14.32, ${\geq}$15.22, and ${\geq}$7.57, respectively. These results indicate that the production process for acelluar BAM has a sufficient virus-reducing capacity to achieve a high margin of the virus safety.

A Case Study about Counting Uncertainty of Radioactive Iodine (131I) in Public Waters by Using Gamma Spectrometry (감마분광분석을 이용한 환경 중 방사성요오드(131I)의 측정 불확도에 관한 사례 연구)

  • Cho, Yoonhae;Seol, Bitna;Min, Kyoung Ok;Kim, Wan Suk;Lee, Junbae;Lee, Soohyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • The radioactive iodine ($^{131}I$) presents in the environment through the excrete process of nuclear medicine patients. In the detecting of low level of $^{131}I$ in the public water, the counting uncertainty has an effect on the accuracy and reliability of detecting $^{131}I$ radioactivity concentration. In this study, the contribution of sample amount, radioactivity concentration and counting time to the uncertainty was investigated in the case of public water sample. Sampling points are public water and the effluents of a sewage treatment plant at Sapkyocheon stream, Geumgang river. In each point, 1, 10 and 20 L of liquid samples were collected and prepared by evaporation method. The HPGe (High Purity Germanium) detector was used to detect and analyze emitted gamma-ray from samples. The radioactivity concentration of $^{131}I$ were in the range of 0.03 to 1.8 Bq/L. The comparison of the counting uncertainty of the sample amount, 1 L sample is unable to verify the existence of the $^{131}I$ under 0.5 Bq/L radioactivity concentration. Considering the short half-life of $^{131}I$ (8.03 days), a method for measuring 1 L sample was used. However comparing the detecting and preparing time of 1, 10 L respectively, detecting 10 L sample would be an appropriate method to distinguish $^{131}I$ concentration in the public water.

Validation Study for Image Performance of I-131 Using GATE Simulation Program (GATE 시뮬레이션 프로그램을 이용한 I-131의 영상 특성의 타당성에 관한 연구)

  • Baek, Cheol-Ha;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.133-137
    • /
    • 2017
  • The purpose of this study was to validate for GATE (Geant4 Application for Tomographic Emission) simulation by comparing the results of GATE simulation and experiment in real SPECT system. Futhermore, we want to prove that it is possible that the quantitative research of gamma camera/SPECT imaging for therapeutic radio isotope by using GATE simulation. In this study, the SPECT system on simulation referred to the parameters of Stream-R Forte version 1.2 (Philips Medical System, Best and Heerlen, Netherlands). To understand the I-131 image of gamma camera/SPECT system, we acquired the energy spectrum and measured the full width at half maximum (FWHM) which comes from line spread function (LSF) with and without scatter material in real SPECT system. And to compare with experiment, we also measured the FWHM and acquired the energy spectrum without scatter material in GATE simulation. As a result, without scatter material, the energy peak was almost same location, which are located nearby 364 keV, and other spectrum factors are same tendency in both cases. The FWHM was increased by increasing the distance of source to detector, and the error rate was approximately 3.8%. When we used the line source with scatter material, energy spectrum also indicated similar tendency in both cases. As you confirmed earlier, GATE simulation included real instrument and radioisotope characters for therapeutic radioisotope. Therefore this result that it was possible that various quantitative study for therapeutic radioisotope imaging in gamma camera/SPECT using GATE simulation.

A Study on the Energy and Time Characteristics of $BaF_2$ Scintillation Detector ($BaF_2$ 검출기의 시간과 에너지 특성연구)

  • Ju, Gwan-Sik;Park, Il-Jin;Kim, Jong-Ho;Nam, Gi-Yong;Baek, Seung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.267-272
    • /
    • 1997
  • he scintillation detector having $BaF^2$ crystal with 3.6cm dia${\times}$2.0 cm thick was provided. The energy and timing characteristics were measured and compared with NaI(Tl) scintillation detectors, which widely used in unclear medicine. In order to measure the energy spectrum, the radioactive sources used were $^{22}Na,\;^{54}Mn,\;^{57}Co,\;^{137}Cs$ and the source to detector distance was 7cm. For the timing characteristic, NaI(Tl)(1" ${\times}$ 1")-$BaF^2$ and NaI(Tl)(3" ${\times}$ 3")-$BaF^2$ timing coincidence systems were prepared and the used source was $^{22}Na$ emitting 511keV annihilation photons. For the 511keV gamma-ray emitted from $^{22}Na$, It was revealed that the timing response of the $BaF^2$ detector was faster than NaI(Tl)(1" ${\times}$ 1") and NaI(Tl)(3" ${\times}$ 3") detector used in this experimental investigation. The energy characteristics of the $BaF^2$ detector had a good values for about 500keV energy range.

  • PDF