• Title/Summary/Keyword: 감마선 검출

Search Result 291, Processing Time 0.028 seconds

A Study on the Neutron Activation Analysis of Noble Metals in the Ancient Coin (고전(古錢)내 귀금속 원소의 중성자 방사화 분석에 관한 연구)

  • Kwon Soo Chun;Chul Lee;Myung-Zoon Czae;Jong Du Lee;Koo Soon Chung
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.11
    • /
    • pp.961-966
    • /
    • 1993
  • The determination of noble metals such as Ir, Au and Ag in the ancient coins has been studied. For the measurement of the activity of $^{192}Ir,\;^{198}Au\;and\;^{110m}Ag$, radiochemical separations including solvent extraction and ion-exchange chromatography were applied to reduce the interference of high energy ${\gamma}$-ray emitted from various radionuclides with long half-life. As a results, $10^{-11}$ g/g level of Ir could be detected and it was found that the three kinds of the detection limits, i.e., critical, detection, quantitative limit, calculated by the method proposed by Currie, were enhanced. Prior to the re-irradiation with neutron, inactive carrier was added in order to determine the recovery yield of Ir in the radiochemical separation. The average recovery yields of Ir, Au and Ag in the 5 coins were 65.3%, 98.5%, 99.5%, respectively.

  • PDF

Search for the activity measurement of radionuclides I-131 (131I을 이용한 방사능 측정에 관한 연구)

  • Baek, Seong-Min;Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.79-82
    • /
    • 2012
  • Iodine is one of important nuclides to be checked for radiation exposure after nuclear power facility accidents. After Chernobyl accident, it was observed that there is a greater amount of organic iodine in the atmosphere than inorganic iodine. In this study, we not only varied the amount of sample being exposed to $^{131}I$ and the duration of exposure to $^{131}I$ but also diluted the sample in distilled water and mixed the sample in kelp and liquid $^{131}I$ to measure and analyze the radiation detection levels. We concluded that the radiation levels were not high enough to be harmful to human body. The radiation from $^{131}I$ decreased over time, and we calculated the half life at 7-9 days. We found that the radiation from any sample containing $^{131}I$ was halved by up to 7days.

Development of High Stable Instrumentation and Analytic Techniques for Radioactive Pulses (방사선 펄스의 고안정 계측 및 분석기술 개발)

  • 길경석;송재용;한주섭;김일권;손원진
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.303-308
    • /
    • 2001
  • An objection of this study is to develop a high stable measuring circuits and a analytic system for radioactive pulses. The proposed system consists of a pulse detection units for neutrons and gamma-rays a programmable high voltage supply unit and a digital signal processor. The programmable high voltage supply unit designed can generate DC voltage up to 1,500 V at 5 V input and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHzAlso, pulse height distribution in accordance with pulse counts is important data in analyzing radioactive pulses. In this study, A/D convertor (12bit, 100ms) and DSP (TMS320C31-60) are used to analyze the pulse height, and the analytic system is designed to be operated in PC-base.

  • PDF

Microbiological and Sensory Qualities of Musaengchae(Radish Salad) with Gamma-irradiated Red Pepper Powder added Prior to Storage (감마선 조사된 고춧가루 첨가 무생채의 저장 중 품질 변화)

  • Kim, Sun-Im;Park, Jae-Nam;Cho, Won-Jun;Song, Beom-Seok;Kim, Jae-Hun;Byun, Myung-Woo;Sohn, Hee-Sook;Lee, Ju-Woon
    • Food Science and Preservation
    • /
    • v.16 no.2
    • /
    • pp.160-165
    • /
    • 2009
  • Microbiological and sensory qualities of Musaengchae prepared with gamma-irradiated red pepper powder were investigated during storage at $4^{\circ}C$. Total aerobic bacteria in non-irradiated raw materials prior to Musangchae preparation were 6.71 log CFU/g in red pepper powder, 3.39 log CFU/g in radish, 2.21 log CFU/g in scallion, and 2.10 log CFU/g in garlic, respectively. Coliforms(2.15 log CFU/g) were detected only in red pepper powder, and not in Musangchae to which gamma-irradiated red pepper powder. None of pH, Hunter's color value, or sensory properties were significantly affected by addition of irradiated red pepper powder. These results suggest that addition of such powder, after irradiation with less then 10 kGy, could improve Musangchae microbiological safety without changing the sensory or physical qualities.

Acridine Orange Stained Micronucleus Assay in Human B and T-lymphocytes after Low Dose ${\gamma}-irradiation$ (아크리딘 오렌지 형광염색법을 이용한 저선량 감마선 유도 말초혈액 B와 T-림프구 미소핵 분석)

  • Choi, Jeong-Mi;Kim, Hee-Sun;Yang, Kwang-Hee;Kim, Cha-Soon;Lim, Yong-Khi;Kim, Chong-Soon;Woon, Jae-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.9-15
    • /
    • 2004
  • Firstly, we compared the two staining techniques, Giemsa and Acridine orange, to determine micronuclei on samples of cultures of five healthy human peripheral blood lymphocytes after ${\gamma}-irradiation\;(^{137}Cs)$ in dose ranges of 0 to 800cGy. It was found that the Acridine orange staining method gives more reliable results than the usual Giemsa staining method in micronucleus tests. Moreover, the frequency of micronuclei in cytokinesis-blocked human B-lymphocytes was studied after in vitro irradiation in dose ranges of 0 to 50cGy. After setting and separating the B-lymphocytes, the frequency of radiation-induced micronuclei were observed as the end-point markers for the low-dose radiation dosimetry after staining with Giemsa and Acridine orange dyes. The micronuclei frequency in B-lymphocytes was significantly elevated from 10 to 30cGy ${\gamma}-irradiation$. The determination of micronuclei in B-lymphocytes after staining with Acridine orange was higher than that of Giemsa. The frequency of micronuclei in B-lymphocytes was observed to be at least two times higher than those of T-lymphocytes Giemsa in dose increasing. Therefore, the determination of low-dose radiation-induced micronuclei in B-lymphocytes after staining with Acridine orange is likely to have the greatest potential in the estimation of low dose radiation exposure.

Effect of γ-Irradiation on the Volatile Organic Compounds from Leek (Allium tuberosum R.) (부추(Allium tuberosum R.)의 감마선 조사에 의한 휘발성 유기화합물의 성분 변화)

  • Han, Byung-Jae;Yang, Sook-Young;Kim, Jun-Hyoung;Shim, Sung-Lye;Gyawali Rajendra;Lee, Sung-Jin;Kim, Kyong-Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.4
    • /
    • pp.513-518
    • /
    • 2005
  • Volatile compounds of $\gamma-irradiation$ leeks (Aillum tuberosum R.) were isolated by simultaneous steam distillation and extraction method (SDE) and analyzed by gas chromatography/mass spectrometry (GC/MS) along with the non-irradiated sample. Leeks were irradiated at dose of 20 kGy and non-irradiated samples were considered as control sample. 56 and 54 compounds were identified in non-irradiated and irradiated samples, respectively. These components included the functional groups; alcohols, aldehydes, esters, ketones, N- and S-containing compounds. S-containing compounds such as dimethyl trisulfide, methyl-(Z)-l-proenyl trisulfide, dimethyl disulfide, 3-ethyl-l,2-dithi-5-ene and methyl allyl disulfide were the major compounds. Methyl-(Z)-l-propenyl trisulfide, diallyl trisulfide, (E)-2-hexanal and 3-ethyl-l,2-dithi-5-ene were clearly decreased by the $\gamma-irradiation$, but dimethyl disulfide, diallyl sulfide, allyl methyl sulfide and pyridine were increased by the $\gamma-irradiation$.

Simultaneous Determination of Titanium, Zirconium and Niobium by Reactor Neutron Activation (원자로 중성자에 의한 티탄, 지르코늄 및 니오브의 동시 정량)

  • Chul Lee;Yung Chang Yim;Koo Soon Chung
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 1974
  • The fission neutron reactions of $^{47}Ti(n.p)^{47}Sc$ and $^{93}Nb(n,{\alpha})^{90m}Y$, along with epicadmium neutron reaction of $^{96}Zr(n,{\gamma})^{97}Zr$ were used for the simultaneous determination of Ti, Nb and Zr in synthetic mixture. Prior to neutron irradiation, Ti, Zr and Nb in the mixture were separated together in one group through the cation exchange column of Dowex $50{\times}8$ resin using 0.5 M ${\alpha}$-hydroxy-iso-butyric acid as the eluent. After irradiation of the eluate the product nuclides, $^{97}Zr$, ^{47}Sc$ and ^{90m}Y$, were eluted sequentially through the same column with 0.5 M ${\alpha}$-HIBA, 0.5 M ${\alpha}$-HIBA-1 N HNO_3 and 0.5 M ${\alpha}$-HIBA-2 N HNO_3$ solution, respectively. The gamma-ray spectrometry was used for the measurement of the gamma-ray activities of the eluted nuclides. The detection limits of Nb, Ti and Zr were found to be 0.2 %, 0.01 % and 0.002 %, respectively.

  • PDF

Fabrication of Miniature Radiation Sensor Using Plastic Optical Fiber for Medical Usage (플라스틱 광섬유를 이용한 초소형 의료용 방사선 센서 제작)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Cho, Hyo-Sung;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.9-12
    • /
    • 2005
  • In this study, film type radiation sensor tips are fabricated for remote sensing of X or g-ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by X and g-ray is guided by the plastic optical fiber and is measured by optical detector and power-meter. It is expected that the fiber-optic radiation sensor which is possible to be developed based on this study is used for remote, fast and exact sensing of X or g-ray because of its characteristics such as very small size, light weight and no interference to electromagnetic fields.

  • PDF

Identification of Irradiated Seafood Cooking Drips Using Various Detection Methods (수산 자숙액의 방사선 조사 여부 판별 특성 연구)

  • Choi, Jong-Il;Kim, Yeon-Joo;Kim, Jae-Hun;Lee, Ju-Woon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.11
    • /
    • pp.1569-1574
    • /
    • 2011
  • In this study, the identification of the irradiated seafood cooking drips from Hizikia fusiformis, Enteroctopus dofleini and Thunnus thynnus was conducted. The physical detection methods used included photo-stimulated luminescence (PSL) and thermoluminescence (TL), and the chemical detection methods were hydrocarbons analysis. In the PSL study, all seafood cooking drip samples showed 260~510 photon counts; thus, the PSL method could not be used for the detection of irradiated seafood cooking drips. The TL method could be used for the detection of irradiated H. fusiformis and E. dofleini cooking drips. In both cooking drips, the shapes of the glow curves indicated a specific peak at 150$^{\circ}C$~250$^{\circ}C$, which made it possible to identify the irradiated samples. The hydrocarbons derived by gamma irradiation of T. thynnus cooking drip were not detected due to low concentration and inconsistent content of fatty acids in the untreated T. thynnus cooking drip.

Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution (감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가)

  • Shin, Sang Hun;Yoo, Wook Jae;Jang, Kyoung Won;Cho, Seunghyun;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.