• Title/Summary/Keyword: 감도 계수법

Search Result 120, Processing Time 0.034 seconds

Determination of Glutathione in Biological Samples by Ion-pairing HPLC/FLD (이온쌍 HPLC/FLD를 이용한 생체 시료중의 Glutathione 농도 분석)

  • Yoo, Jeong-Yeon;Lee, Kyoung-Ok;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 1999
  • Glutathione(GSH) in biological samples was determined by high performance liquid chromatographic(HPLC) method with fluorescence detector(FLD) after monobromobimane(MBB) or 4-fluoro-7-sulfobenzofurazan(SBD-F) derivatization. The detection limit of $0.03{\mu}g/mL$ was obtained after MBB derivatization, derivative of MBB was about 200 times more sensitive than that of SBD-F. N-acetylcysteine was used as internal standard and tetrabutylammonium ion as counter ion for better separation. The determination by ion-pairing chromatography after MBB derivatization was characterized by linearity in the range between $0.08{\sim}8.33{\mu}g/mL$ with a good correlation coefficient of 0.998. By precision test appeared relative standard deviation at less than 5% at three different concentrations. This method can be used for the analysis of GSH in plasma and tissue.

  • PDF

Fabrication and Characteristic of an InSb Mognetic Flvxmeter (InSb 자속계의 제작과 그 특성에 관한 연구)

  • 윤재강;유용택
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.6
    • /
    • pp.5-8
    • /
    • 1975
  • An Insb magnetic fluxmeter was made of InSb Single Crystal that was grown by Bridgemannmethods and then purified by vapor cone refining method. We investigated some properties of the InSb magneto fluxmeter. It was found that the resistivity and the Hall Coefficient of this single Crystal Were 4.4${\times}10^{-2}{\Omega}$ and $4.5\textrm{cm}^3$/Coul, respectively, at room temperature. The Characteristic Curve of the InSb magnetic fluxmeter between the magnetic field the Hall voltage, with the Current flowing through the element a Parameter, had good lineanty i.e., We obtained a linear Calibration Curve of the flwmeter. The fluxmeter erved the purpose well enough up to 5 k-gaus.

  • PDF

V-Zn계 산화물을 이용한 마이크로볼로미터적외선 센서의 구현

  • Han, Myeong-Su;Kim, Dae-Hyeon;Choe, In-Gyu;Go, Hang-Ju;Eom, Ju-Beom;Park, Jae-Seok;Sin, In-Hui;Lee, Byeong-Il;Kim, Du-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.376.2-376.2
    • /
    • 2014
  • 마이크로볼로미터 적외선 센서는 인체감지, 전자부품의 품질검사, 에너지 절감, 산업시설감시 및 군사용으로 다양하게 적용되고 있다. 기존에 이러한 적외선 센서의 감지재료로 VOx 또는 비정질 Si이 가장 많이 사용되고 있으며, VOx는 감도가 높고, 세계적으로 가장 많이 사용되고 있는 물질이다. 본 연구에서는 기존의 VOx 박막 증착법을 개선하여 Zn 산화물 박막을 혼용한 적외선 감지재료를 이용한 마이크로볼로미터 제작 및 특성에 대해 보고한다. RF sputtering 방법으로 약 140 nm의 VOx/ZnO/VOx 샌드위치 박막을 증착하고, 산소분위기에서 열처리함으로써 온도저항계수(TCR)가 약 -3.0 %/K의 값을 갖는 특성을 구현하였다. 갓 증착된 V-Zn 박막에서는 XRD 스펙트럼에서는 V2O5 관련 피크가 주로 관측되었으며, 산소열처리에 의해 VO2 피크가 새롭게 관측되었다. 볼로미터 감지소자는 유효면적 $50{\times}50{\mu}m^2$ 으로 bulk micromaching 공정을 통해 제작하였다. Si 기판위에 SiNx 박막을 PECVD 장치를 이용하여 증착하였으며, 적외선 감지층으로 V-Zn 산화물을 RF sputtering 방법으로 증착하여 열처리 후 SiNx passivation 박막으로 보호하였다. 열적고립을 위해 패터닝 후 Si 기판을 KOH 용액을 이용하여 약 $20{\mu}m$ 식각하여 소자를 구현하였다. 제작된 소자의 특성을 평가한 결과 반응도는 1.57e+4 V/W, 탐지도는 $8.79e+7cmHz^{1/2}/W$를 얻을 수 있었다. 소자의 동작 특성을 평가하기 위해 진공 압력을 1e-3 torr 이하에서 thermoelectric cooler를 장착한 metal package를 제작하여 동작온도에 따른 특성을 평가하였다. 동작온도를 $10^{\circ}C{\sim}40^{\circ}C$로 하여 측정한 결과 동작온도가 증가할수록 신호전압은 감소함을 알 수 있었다.

  • PDF

Determination of Sulfur Compounds in Gaseous Fuel by Gas Chromatography-Sulfur Chemiluminescence Detection (GC-SCD를 이용한 가스연료 중 황화합물의 정량)

  • Do, Lee Joo;Koh, Jae Suk;Kim, Ho Jin
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.5
    • /
    • pp.517-521
    • /
    • 1999
  • Gas chromatography using sulfur chemiluminescence detection (GC-SCD) which exhibits very good selectivity, linearity, and sensitivity was applied to the analysis of suIfur compounds in gaseous fuel. The expectmental method used in this study was to resolve the problems of repeatability and reproducibility by means of the adsorption of sulfur compounds, which is different from the existing analysis method of these compounds by GC-SCD. The calibration curves of the standard gases including dimethyl sulfide, t-butylmercaptan and ethyl methyl sulfide exhibited an excellent linearity. As the result of precision tests for the above three compounds, the high reproducibility for tests showed while repeating three times during four days, respectively. In addition, the coefficient of variation was less than 3%. In consequence, the expectmental method of this study is very effective not only with low uncertainty but also with better accuracy, which can quickly determine the concentration of gas odorants in LPG (Liquefied Petroleum Gas) from oil reservoirs and filling stations.

  • PDF

Simultaneous determination of amphetamine derivatives and norketamine in hair by GC-MS/MS (GC-MS/MS를 이용한 모발 중 암페타민 유도체 및 노르케타민 동시분석)

  • Kim, Jin Young;Shin, Soon Ho;Ko, Beom Jun;Chung, Jae Cheol;Suh, Yong Jun;In, Moon Kyo
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.210-218
    • /
    • 2009
  • A gas chromatography-tandem mass spectrometry (GC-MS/MS) method was developed and validated for simultaneous determination of amphetamine derivatives and norketamine in human hair. Preparation of hair involves external decontamination, mechanical pulverization, incubation and extraction prior to instrumental analysis. The samples were derivatized using heptafluorobutyric anhydride, and analyzed by GC-MS/MS. The linear ranges were 0.05-20.0 ng/mg for the analytes except for 3,4-methylenedioxyamphetamine, with good coefficients of determination ($r^2$ >0.998). The intra-day and inter-day precisions were within 10.7% and 8.5%, respectively. The intra-day and inter-day accuracies were between -1.6 and 17.0% and -2.6 and 10.5%, respectively. The limits of detections for each analyte were lower than 0.007 ng/mg, while recoveries were 75.9-100.9%. When the method was applied to hair samples obtained from suspected drug abusers, the concentrations in hair samples were 0.97-19.30 ng/mg for methamphetamine and 0.14-2.56 ng/mg for amphetamine.

Analysis of PAHs (polycyclic aromatic hydrocarbons) in Ground Coffee Using GC-tandem Mass Spectrometry and Estimation of Daily Dose (GC-tandem mass spectrometry를 이용한 분쇄원두커피 중 PAHs(polycyclic aromatic hydrocarbons) 분석법 연구 및 인체노출량 평가)

  • Jung, So-Young;Park, Ju-Sung;Son, Yeo-Joon;Choi, Su-Jeong;Lee, Yun-Jeong;Kim, Mi-Sun;Park, So-Hyun;Lee, Sang-Me;Chae, Young-Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.544-552
    • /
    • 2011
  • The purpose of this study was to develop an analytical method for determining 15 polycyclic aromatic hydrocarbons (PAHs) of EU priority using gas chromatography (GC)-tandem mass spectrometry (MS). The PAHs in ground coffee were analyzed after being extracted using methods such as saponification-liquid-liquid extraction, Soxhlet extraction, and solid-liquid extraction. The solid-liquid extraction method showed the greatest repeatability and most efficient reduction of the matrix effect. GC-tandem MS for the quantification of the 15 PAHs showed better resolution and lower limit of detections (LODs) than GC-MS-selected ion monitoring (SIM) and high performance liquid chromatography with fluorescence detector. LODs of this method for the ground coffee types were 0.002-0.1 ${\mu}g/kg$ and limit of quantifications (LOQs) were 0.006-0.2 ${\mu}g/kg$ The recoveries ranged from 52.6 to 93.3%. Forty-six commercial types of ground coffee were analyzed to determine their PAHs contamination levels. PAHs concentration ranged from ND to 5.988 ${\mu}g/kg$. This study was conducted with toxicity equivalence factors, the U.S. EPA recommendation to identify dietary risks for PAHs in different types of coffee. The estimated average daily dose of PAHs was $5.24{\times}10^{-8}$ mg/kg body weight/day.

Shoulder Uptake in the Bone Scintigraphy in Patients with Hemiplegic Reflex Sympathetic Dystrophy Syndrome (반신마비성 반사성교감신경 이영양증후군 환자의 골스캔상 견관절 섭취)

  • Lee, Jong-Jin;Chung, June-Key;Lee, Dong-Soo;Hong, Joon-Beom;Han, Tai-Ryoon;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.288-293
    • /
    • 2004
  • Purpose: increased uptake of wrist and hand joints in three phase bone scintigraphy (TPBS) have been used in the detection of reflex sympathetic dystrophy syndrome (RSDS). TPBS frequently shows increased shoulder uptake in the hemiplegic RSDS patients. We investigated the significance of the shoulder uptake in the detection of these patients. Materials and Methods: Twenty three patients who had hemiplegia due to brain stroke and diagnosed as RSD were enrolled in this study (M:F=16:7, R:L=11:12). The mean age was $63{\pm}10$ yrs. Ter normal volunteer (mean age: $60{\pm}5$, M:F=1:9) data was used as control group. TPBS was performed $59{\pm}32$ days after stoke (acute stage). We obtained the count ratios of bilateral hands by drawing a region of interest (ROI) in three phase images and compared to the count ratios of shoulders in the delayed image. Hand ROI included an ipsilateral wrist. Sensitivity of detecting the affected limb was defined using the right/left count ratio of normal control. Results: Sensitivities using count ratios of hand blood flow, blood pool and delayed image were 45%, 76% and 78%, respectively. Sensitivity of shoulder count ratio was 74%. Log of right/left counts of hand delayed image and that of shoulder delayed image were correlated well with statistical significance (Spearman's R=0.824, p<0.001). Conclusion: Shoulder uptake showed good correlation with hand uptake in the delayed image of TPBS. Shoulder uptake maybe helpful in the diagnosis of reflex sympathetic dystrophy syndrome in patients with hemiplegia.

Evaluation of The Physical Suitability of Chairs Using Conjoint Analysis (Conjoint Analysis를 이용한 의자의 물리적 적합도 평가)

  • 신미경;김진호;박수찬;최경주;윤지은
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.32-37
    • /
    • 1999
  • 본 연구는 컨조인트 분석기법을 이용하여 의자의 물리적 적합도를 분석, 평가하여 사용자가 선호하는 최적의 의자를 제시하고자 하는데 목적이 있다. 컨조인트 분석기법은 Marketing 분야에서 주로 많이 쓰여온 분석 방법으로서 제품의 중요한 속성들을 찾아내어 다양한 종류의 제품들에 대한 고객의 선호도를 분석하는 방법이다. 이러한 컨조인트 분석기법은 제품개발과 평가의 측면에서 매우 큰 가능성이 있음에도 불구하고 마켓팅 이외의 분야에서는 거의 적용되자 않고 있는 실정이다. 따라서 본 연구에서는 의자의 물리적 적합성 연구에 이 컨조인트 분석을 이용하여 그 적용의 가능성을 알아보고자 하였다. 또한 이러한 적합성 연구에 컨조인트 분석기법이 타당한 분석기법인지 비교하기 위해 분산분석의 기법도 병행하여 실시하였다. 문헌 조사와 전문가 의견 수렴을 통하여 선행연구에서 추출된 의자의 물리적 적합도 요소인 안정성, 여유성, 적합성, 안락성등 4개의 적합도 요소를 채택하여 종속변수로 사용하였다. 또한 의자 자체의 설계 요소에 해당하는 휴먼인터페이스 요소(HIE)는 높이 조절 여부, 팔걸이 유무, Tilting 유무의 3가지 속성을 선택하여 독립변수로 사용하였다. 분석에 사용된 의자는 각 속성을 특징적으로 대표하는 8개의 의자들로서 구성하였고 63명의 피험자를 사용하여 실험하였다. 분석의 결과는 안정성에 가장 큰 영향을 주는 속성은 높이조절(HC)로서 남자와 여자 모두 높이조절 기능이 없을 때 안정성을 느낀다는 결과가 나왔다. 여유성에 영향을 주는 가장 큰 요인은 남자는 높이조절 기능이 있을 때, 여자는 팔걸이가 있을 때 여유성이 있다고 판단하였으며, 인체적합성에 영향을 주는 요인은 남자와 여자 모두 Tilting 기능이, 안락성에 영향을 주는 주요인은 남자는 Tilting 기능이 있을 매, 여자는 높이조절 기능이 있을 때인 것으로 나타났다.감, 강연성, 회복성, 수분특성, 밀도감이었으며, 요인들로 설명되는 누적분산값은 67.18%였다.주관적 평가의 결과와 객관적 평가 결과를 이용해 마직물의 태를 평가하는 산출식을 제시하였다. 태 평가치의 경우 16가지 특성치를 모두 넣는 방법과 stepwise 방법, 또 Kawabatark 사용한 순차적 군 회귀법의 세가지 방법의 회귀식 중 16가지 특성치를 모두 넣는 방법의 결정계수가 가장 높았다.tosterone농도는 107.7$\pm$12.0 pmol/l이었고, 남성의 타액내 농도는 274.2$\pm$22.1 pmol/l이었다. 이상의 결과로 보아 본 연구에서 정립된 EIA 방법은 RIA를 대신하여 소규모의 실험실에서도 활용할 수 있을 것으로 사려된다.또한 상실기 이후 배아에서 합성되며, 발생시기에 따라 그 영향이 다르고 팽창과 부화에 관여하는 것으로 사료된다. 더욱이, 조선의 ${\ulcorner}$구성교육${\lrcorner}$이 조선총독부의 관리하에서 실행되었다는 것을, 당시의 사범학교를 중심으로 한 교육조직을 기술한 문헌에 의해 규명시켰다.nd of letter design which represents -natural objects and was popular at the time of Yukjo Dynasty, and there are some documents of that period left both in Japan and Korea. "Hyojedo" in Korea is supposed to have been influenced by the letter design. Asite- is also considered to have been "Japanese Letter Jobcheso." Therefore, the purpose of

  • PDF

Simultaneous GC/MS Analyses of Organic acids and Amino acids in Urine using TMS-TFA derivative (TMS-TFA 유도체화를 이용한 소변여지 중 유기산과 아미노산의 GC/MS 동시분석)

  • Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.107-114
    • /
    • 2006
  • Early diagnosis and medical intervention are critical for the treatment of patients with metabolic disorders. A rapid analytical method was developed for simultaneous quantification of organic acids and amino acids in urine without labor-intensive pre-extraction procedure showing high sensitivity and specificity. A new method consisted of simple two-step trimethylsilyl (TMS)-trifluoroacetyl (TFA) derivatization using GC/MS-selective ion monitoring (SIM). Filter paper urine specimens were dried under nitrogen after being fortified with internal standard (tropate) in a mixture of distilled water and methanol. Methyl orange was added to the residue as indicator reagent. Silyl derivative of carboxylic functional group was followed by trifluoroacetyl derivative for amino functional group. N-methyl-N-(trimethylsilyl-trifluoroacetamide) and N-methyl-bistrifluoroacetamide were consecutively added and heated for 15-20 min at $65^{\circ}C-70^{\circ}C$, for TMS-TFA derivative, respectively. This reactant was analyzed by GC/MS-SIM. Linear dynamic range showed 0.001-50 mg with the detection limit of (S/N=3) 10-200 ng, and the quantification limit of 80-900 ng in urine. Correlation coefficient of regression line was 0.994-0.998. When the method was applied to the patients 'urine, it clearly differentiated the normal from the patient with metabolic disorder. The study showed that the developed method could be the method of choices in rapid and sensitive screening for organic aciduria and amino acidopathy.

Intra-laboratory Validation of an HPLC Post-column Oxidation Method for the Analysis of PSP Toxins in Oysters and Mussels (굴과 진주담치 중 마비성 패류독소 분석을 위한 HPLC post-column oxidation method의 시험소 내 유효성 검증)

  • Song, Ki Cheol;Lee, Ka-Jeong;Yu, Hong-Sik;Mok, Jong-Soo;Kim, Ji Hoe;Lim, Keun-Sik;Lee, Mi-Ae;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.241-247
    • /
    • 2013
  • AOAC Mouse Bioassay Analysis (MBA) has been the gold standard for the analysis of paralytic shellfish poisoning toxin (PSP toxin) for more than 50 years. However, this method has inaccurate limit of quantification and cannot be used to determine toxic profiles. An HPLC method (PCOX) was optimized for Korean shellfish to establish an alternative or supplementary method for PSP analysis and was intended to be used for the official monitoring and regulation of food. The recovery rate of the PCOX method was 83.5-112.1% and the limit of quantification for total toxin was about $8.6{\mu}g$/100 g. A long-term comparison study showed a good correlation of the PCOX results with the AOAC MBA results: the correlation factors were 0.9534 and 0.9109 for oyster and mussel matrices, respectively. The PCOX method may be used as an alternative or supplementary method for AOAC MBA to monitor the occurrence of PSP and to analyze PSP toxin profile in oysters and mussels.