• Title/Summary/Keyword: 감도 계수법

Search Result 120, Processing Time 0.025 seconds

Interfacial Properties and Sensing of Carbon Nanofiber/Tube and Electrospun Nanofiber/Epoxy Composites Using Electrical Resistance Measurement and Micromechanical Technique (전기저항측정 및 미세역학시험법을 이용한 탄소나노섬유/튜브 및 전기방사된 나노섬유/에폭시 복합재료의 계면특성 및 감지능 연구)

  • Jung Jin-Gyu;Kim Sung-Ju;Park Joung-Man
    • Composites Research
    • /
    • v.18 no.4
    • /
    • pp.21-26
    • /
    • 2005
  • Nondestructive damage sensing and load transfer mechanisms of carbon nanotube (CNT) and nanofiber (CNF)/epoxy composites have been investigated by using electro-micromechanical technique. The electrospun PVDF nanofibers were also prepared as a piezoelectric sensor. The electro-micromechanical techniques were applied to evaluate sensing response of carbon nanocomposites by measuring electrical resistance under an uniform cyclic loading. Composites with higher volume content of CNT showed significantly higher tensile properties than neat and low volume$\%$ CNT composites. CNT composites showed humidity sensing within limited temperature range. CNT composites with smaller aspect ratio showed higher apparent modulus due to high volume content in case of shorter aspect ratio. Thermal treated electrospun PVDF nanofiber showed higher mechanical properties than the untreated case due to crystallinity increase, whereas load sensing decreased in heat treated case. Electrospun PVDF nanofiber web also showed sensing effect on humidity and temperature as well as stress transferring. Nanocomposites and electrospun PVDF nanofiber web can be applicable for sensing application.

Evaluation the Output Dose of Linear Accelerator Photon Beams by Blind Test with Dose Characteristics of LiF:Mg,Cu,P TLD (LiF:Mg,Cu,P 열형광선량계의 선량특성을 이용한 눈가림법에 의한 출력선량 평가)

  • Choi, Tae-Jin;Lee, Ho-Joon;Yie, Ji-Won;Oh, Young-Gi;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.308-316
    • /
    • 2009
  • To achieve the accurate evaluation of given absorbed dose from output dose of linear accelerator photon beam through investigate the characteristics of LiF:Mg,Cu,P TLD powder. This experimental TL phosphor is performed with a commercial LiF:Mg,Cu,P powder (Supplied by PTW) and TL reader (LTM, France). The TLD was exposed to 6 MV X rays of linear accelerator photon beam with range 15 to 800 cGy in blind dose at two hospitals. The dose evaluation of TLD was through the experimental algorithms which were dose dependency, dose rate dependency, fading and powder weight dependency. The glow curve has shown the three peaks which are 110, 183 and 232 degrees of heating temperature and the main dosimetric peak showed highest TL response at 232 high temperature. In this experiments, the LiF:Mg,Cu,P phosphor has shown the 2.5 eV of electron trap energy with a second order. This experiments guided the dose evaluation accuracy is within 1% +2.58% of discrepancy. The TLD powder of LiF:Mg,Cu,P was analyzed to dosimetric characterists of electron captured energy and order by glow shape, and dose-TL response curve guided the accuracy within 1.0+2.58% of output dose discrepancy.

  • PDF

Effect of academic self-efficacy, task value, and class participation of college students on learning satisfaction through flip learning (플립러닝 학습법을 통한 대학생의 학업적 자기효능감, 과제가치, 수업참여도가 학습만족도에 미치는 영향)

  • Ju, Hyeon Jeong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.211-225
    • /
    • 2021
  • The purpose of this study was to investigate the effect of academic self-efficacy, task value, behavioral participation, cognitive participation, emotional participation, and initiative participation on learning satisfaction in 462 college students who took a flip learning class. Results, As for the direct effect of variables affecting learning satisfaction, behavioral participation was the largest factor, followed by initiative participation, task value, emotional participation, and academic self-efficacy. These variables explained 86% of learning satisfaction. Academic self-efficacy and task value had an indirect effect on learning satisfaction through behavioral, emotional, and proactive participation. In the multi-group moderating effect with the upper-middle class (B+ or higher) and the lower-middle class (below B) group as the moderating variables, there was a partial moderating effect because the path coefficients of leading participation and learning satisfaction differed between the groups. It is necessary to seek various ways to increase the degree of participation in learning and to develop an intervention strategy through a program tailored to each individual.

North Korean Defectors' depression through the CES-D and the Rorschach test (CES-D와 로샤검사를 통해 본 북한이탈주민의 우울감)

  • Jong-Nam Kim;Yun-Kyung Choi;Jung-Min Chae
    • Korean Journal of Culture and Social Issue
    • /
    • v.14 no.2
    • /
    • pp.41-61
    • /
    • 2008
  • This study was performed to investigate the North Korean defectors's depression through the CES-D and a projective test simultaneously. So 40 North Korean defectors and 40 South Koreans participated in this study. The results are the following. First, the North Korean defectors demonstrated more higher CES-D scores than the South Koreans, while there were not significant differences in the Rorschach depression-related indexes, DEPI, CDI, S-CON between two groups. Second, at the analysis of the sex difference effect, women among the North Korean defectors showed the most high CDI index scores. In addition, we analyzed the mean differences between two groups for morbid content, shading response, achromatic response, human movement response, form dimension response, Lamda, and the number of total response. However, there are not significant differences between two groups for those variables, except for form dimension(FD) response. It suggested the probability that the North Korean women defectors could experience more psychological distress underlyingly than the North Korean men defectors. Third, most importantly, the correlation between CES-D and DEPI in the Rorschach test was significantly different in the two groups(the North Korean defectors and the South Koreans). In conclusion, the self-report of the North Korean defectors on depression could be exaggerated. So we should be cautious to interpret the self report results of the North Korean defectors.

  • PDF

Integrated Cavity Output Spectroscopy Using an External Cavity Diode Laser for the Density Absorption Measurement of Trace Gases (미량 기체의 밀도 측정을 위한 외부 공진기 반도체 레이저 광학공동 적분 투과 분광법)

  • Ryoo Hoon Chul;Yoo Yong Shin;Lee Jae Yong;Hahn Jae Won
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.24-30
    • /
    • 2006
  • Integrated cavity output spectroscopy(ICOS) is a simple, non-intrusive absorption measurement technique that can detect and quantify trace-level gas species. The spectral absorbance of a gas is quantified from the integrated optical output of the modulated high-finesse cavity containing the sample which is irradiated by a wavelength-swept laser source. We constructed an experimental setup by using a tunable single mode external cavity diode laser operating at the wavelength near 765 nm and a Fabry-Perot cavity with length modulation achieved by a piezoelectric transducer where one of the cavity mirrors sat on. In the experiment performed on minute oxygen gas at the wave-length near 764.5nm, we demonstrated the minimum detectable absorption of $8.45\times10^{-8}cm^{-1}$.

Optimal HPLC Condition for Simultaneous Determination of Anthocyanins in Black Soybean Seed Coats (검정콩 함유 안토시아닌의 동시분석을 위한 최적 HPLC 분석 조건)

  • Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.4
    • /
    • pp.359-368
    • /
    • 2008
  • Black soybean has been widely utilized as foods and oriental medicinal materials. The pigmentation in the seed coat of black soybean is due to accumulate anthocyanins in the epidermis palisade layer. The anthocyanins of black soybean seed coat are considered as a parameter of quality evaluation of black soybean. Therefore, the purpose of this study was to investigate the most suitable HPLC condition for simultaneous determination of anthocyanins in black soybean seed coats extracts. The efficient HPLC analytical condition of D3G, C3G, and Pt3G contained extracts of black soybean seed coats was developed. The gradient elution employed a $250\;mm\;{\times}\;4.6\;mm$ i.d. YMC-pak ODS-AM 303 column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of 5% aqueous formic acid, and mobile phase B, comprising 5% formic acid - acetonitrile, and delivered at a flow rate of 0.7 mL/min as follows: $0{\sim}35\;min$, $90%\;A{\sim}60%\;A$; 36 min, 90% A; 46 min, 90% A. The UV-VIS. detection wavelength was set at 520 nm. The limit of detection (LOD) for D3G, C3G, and Pt3G were under 10 ng/mL.

Study on a cavity ring-down spectrometer with continuous wave laser sources (연속발진 레이저를 이용한 공동 광자감쇠 분광기 연구)

  • 유용심;한재원;김재완;이재용;이해웅
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.240-244
    • /
    • 1998
  • Cavity ring-down spectroscopy (CRDS) is a high-sensitive laser spectroscopic technique capable of measuring concentrations of trace gases. We have demonstrated a new design of the CRDS spectrometer with a continuous wave (CW) laser. The ring-dwon signal is produced through blocking the incident CW laser by scanning the cavity length fast toward off-resonance iwth PZT (piezoelectric transducer). We have also measured an absorption spectrum of acetylene overtone transitions near 570 nm at the pressure of 2700 Pa, and the minimum detectable absorption coefficient has been found to be about $3{\times}10^{-9}\cm^{-1}$.

  • PDF

An Auto-tuing of PID Conrtroller using Genetic Algorithms (유전자 알고리즘을 사용한 PID제어기의 자동동조)

  • 이수흠;정순현
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.71-75
    • /
    • 2002
  • We propose a new method to deal with the optimized auto-tuning for the PID controller which is used to the process-control in various fields. First of all, in this method, 1st order delay system with dead time which is modelled from the unit step response of the system is Pade-approximated, then initial values are determined by the Ziegler-Nichols method and deciding binary strings of parents generation using by the fitness values of genetic algorithms, we perform selection, crossover and mutation to generate the descendant generation. The advantage of this method is better than the Ziegler-Nickels method in characteristic of output, and has extent of applying without limit of K, L, T parameters.

  • PDF

Associations of Communication Skills, Self-Efficacy on Clinical Performance and Empathy in Trainee Doctors (전공의 의료커뮤니케이션 능력과 진료수행 자기효능감, 공감능력과의 상관관계)

  • Kim, Doehyung;Kim, Min-Jeong;Lee, Haeyoung;Kim, Hyunseuk;Kim, Youngmi;Lee, Sang-Shin
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.29 no.1
    • /
    • pp.49-57
    • /
    • 2021
  • Objectives : This study evaluated the medical communication skills of trainee doctors and analyzed the relationship between medical communication skills, self-efficacy on clinical performance (SECP) and empathy. Methods : A total of 106 trainee doctors from a university hospital participated. The questionnaire comprised self-evaluated medical communication skills, modified SECP and the Korean version of the Jefferson Scale of Empathy-Health Professionals version. The mean difference in medical communication skills scores according to gender, age, division (intern, internal medicine group or surgery group) and position (intern, first-/second- and third-/fourth-year residents) were analyzed. Pearson correlation coefficients were determined between medical communication skills, modified SECP and empathy. The effects of each variable on medical communication skills were verified using the structural equation model. Results : There were no statistically significant mean differences in self-evaluated medical communication skills according to gender, age, division or position. Medical communication skills had a significant positive correlation with modified SECP (r=0.782, p<0.001) and empathy (r=0.210, p=0.038). Empathy had a direct effect on modified SECP (β=0.30, p<0.01) and modified SECP had a direct effect on medical communication skills (β=0.80, p<0.001). Empathy indirectly influenced medical communication skills, mediating modified SECP (β=0.26, p<0.05). Conclusions : Medical communication skills are an important core curriculum of residency programs, as they have a direct correlation with SECP, which is needed for successful treatment. Moreover, the medical communication needs a new understanding that is out of empathy.

Validation of LC-MS/MS method for determination of ertapenem in human plasma and urine (인체 혈장 및 소변 중 에르타페넴의 정량을 위한 LC-MS/MS 분석법 검증)

  • Kim, Yun-Jeong;Han, Song-Hee;Jeon, Ji-Young;Hwang, Min-Ho;Im, Yong-Jin;Chae, Soo-Wan;Kim, Min-Gul
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.19-24
    • /
    • 2012
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of ertapenem in human plasma and urine. After addition of internal standard (ceftazidime), plasma and urine was diluted with methanol and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring (MRM) mode, ertapenem were selectively detected without severeinterference from human plasma and urine. The standard calibration curve for ertapenem was linear ($r^2$= 0.9996)over the concentration range 1~100 ${\mu}g/mL$ in human plasma. The intra- and inter-day precision over the concentration range of ertapenem was lower than 8.9% (correlation of variance, CV), and accuracy was between 97.2~106.2%. On the other hand, it was showed good relationship ($r^2$= 0.9992) and the precision (intra- and inter-day) over the concentration range of ertapenem was lower than CV 7.2%, and accuracy was between 97.9~111.6% for urine. This method has been successfully applied to the pharmacokinetic study of ertapenem in human plasma and urine.