• Title/Summary/Keyword: 감도비

Search Result 444, Processing Time 0.025 seconds

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF

Modified QuEChERS Multi-Residue Analysis Method for 61 pesticides in Fruits using with HPLC and GC-ECD/NPD (HPLC 및 GC-ECD/NPD를 이용한 과일 중 61종 농약의 QuEChERS 전처리 다성분 분석법 개발)

  • Lee, Ju-Young;Hong, Su-Myeong;Kim, Taek-Kyum;Min, Zaw Win;Kim, Yang-Hyeon;Song, Kyung-Ae;Kwon, Hye-Yong;Lee, Hee-Dong;Im, Geon-Jae;Kim, Doo-Ho;Kim, Jang-Eok
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.242-256
    • /
    • 2012
  • QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method has been a lot of research for pesticide analysis, because it is very simple and fast. However, this method requires high sensitivity instrument such as LC-MS/MS because of the use of small sample volume and many impurities compared to the conventional method. So, QuEChERS method needs to be modified for using with HPLC and GC-ECD/NPD. The aim of this work was to study the application of the QuEChERS method as well as its modification for the extraction and preconcentration of 5 groups of 61 pesticides from 4 fruits prior to their determination by HPLC-PDA, GC-ECD/NPD, and LC-MS/MS. The method was validated using spiking levels at 0.1 mg/kg (or 0.01 mg/kg) in apple, grapes, pear and persimmon. The average recovery by QuEChERS AOAC Official 2007. 01 version using the LC-MS/MS varied from 71.1127.4% for 61 pesticides. The average recovery rates using modified QuEChERS varied from 70.9~126% for 61 pesticides by HPLC-PDA and GC-ECD/NPD. The results satisfied the criteria of multiple pesticide residue analysis, setting 70~130% for recovery rates and below 30% for CV.

Survey of Heavy Metal Contents of Circulating Agricultural Products in Korea (국내 유통 중인 농산물의 중금속 함량 모니터링)

  • Kim, Hee-Yun;Kim, Jae-In;Kim, Jin-Chul;Park, Ji-Eun;Lee, Kyung-Jin;Kim, Sung-Il;Oh, Jae-Ho;Jang, Young-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.238-244
    • /
    • 2009
  • This survey was conducted as a surveillance program following the establishment of safety guidelines for agricultural products in Korea. Concentrations of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) were measured in 421 samples using a mercury analyzer or ICP-MS. The average levels of Pb in mg/kg were 0.021 for rice, 0.020 for corn, 0.028 for soybeans, 0.034 for red beans, 0.025 for sweet potatoes, 0.021 for potatoes, 0.019 for Chinese cabbage, 0.031 for spinach, 0.021 for Welsh onions, and 0.011 for radishes. The average levels of Cd in mg/kg were 0.021 for rice, 0.002 for corn, 0.020 for soybeans, 0.006 for red beans, 0.008 for sweet potatoes, 0.011 for potatoes, 0.007 for Chinese cabbage, 0.035 for spinach, 0.006 for Welsh onions, and, 0.006 for radishes. The average levels of As in mg/kg were 0.103 for rice, 0.005 for corn, 0.007 for soybeans, 0.005 for red beans, 0.005 for sweet potatoes, 0.004 for potatoes, 0.007 for Chinese cabbage, 0.015 for spinach, 0.009 for Welsh onions and, 0.006 for radishes. Finally, the average levels of Hg in ${\mu}g/kg$ were 2.3 for rice, 0.2 for corn, 0.6 for soybeans, 1.4 for red beans, 0.1 for sweet potatoes, 0.3 for potatoes, 0.5 Chinese cabbage, 2.1 for spinach, 0.5 for Welsh onions, and 0.2 for radishes. Based on the Korean public nutrition report 2005, these levels (or amounts) are calculated only at 2.6% for Pb, 8.7% for Cd, 1.2% for Hg of those presented in provisional tolerable weekly intake (PTWI) which has been established by FAO/WHO. Therefore, the levels presented here are presumed to be adequately safe.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Diagnostic Value of Serum Beta-hCG Measured by EIA in Suspected Ectopic Pregnancy (EIA로 측정한 혈청 ${\beta}$-hCG치의 자궁외 임신에 대한 진단적 가치)

  • Park, Yoon-Ki;Kim, Jong-Wook;Lee, Tae-Hyung;Park, Wan-Seok;Lee, Sung-Ho;Chung, Wun-Yong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.221-227
    • /
    • 1985
  • Thirty-four patients with suspected ectopic pregnancy whose serum hCG levels had been measured by beta-hCG EIA before surgery were evaluated retrospectively. The results were as follows: 1. Final diagnosis of thirty-four patients with suspected ectopic pregnancy comprised twenty- eight tubal pregnancy, five ruptures of hemorrhagic corpus luteum and, one tubo-ovarian abscess. One of the five patients with rupture of hemorrhagic corpus luteum was accompanied by missed abortion. 2. Range of serum hCG levels in twenty-eight patients with tubal pregnancy was 59-21,980 mIU/ml and that of four patients with rupture of hemorrhagic corpus luteum and one patient with tubo-ovarian abscess was 0.6-6.6mIU/ml. Serum hCG level of a patient with rupture of hemorrhagic corpus luteum who was accompanied by missed abostion was 200 mIU/ml. 3. Serum hCG levels in twenty-two of twenty-eight patients with tubal pregnancy were lower than 3,000 mIU/ml. Low serum hCG level below 100mIU/ml and high serum hCG level above 6,500 mIU/ml were noticed in four and six patients with tubal pregnancy, respectively. 4. Mean serum hCG levels (${\pm}SD$) of twelve patients with tubal pregnancy who had intra-abdominal free blood of less than 500ml and sixteen patients with tubal pregnancy who had intra-abdominal free blood of more than 500ml were 4,131 (${\pm}7,801$) mIU/ml and 3,208 (${\pm}5,081$) mIU/ml, respectively. There was no statistical difference in the mean level of serum hCG between both group (P>0.05). 5. Mean serum hCG levels (${\pm}SD$) of thirteen patients with unruptured tubal pregnancy and fifteen patients with ruptured tubal pregnancy were 2,628 (${\pm}5,448$) mIU/ml and 4,449 (${\pm}6,938$) mIU/ml, respectively. Mean level of serum hCG was statistically higher in ruptured tubal pregnancy (P<0.01). 6. Positive rate of urine pregnancy test in the diagnosis of ectopic pregnancy was 64% (16/25) and mean range of serum hCG level of nine patients with false negative result were 353 mIU/ml and 59-933 mIU/ml.

  • PDF

Monitoring of Paralytic Shellfish Poison by Highly Sensitive HPLC from Commercial Shellfishes and Sea Squirts (고감도 HPLC에 의한 시판 중인 패류 및 멍게의 마비성 패류독 모니터링)

  • Jang, Jun-Ho;Kim, Byung-Yun;Lee, Jong-Baek;Yun, So-Mi;Lee, Jong-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.6
    • /
    • pp.915-923
    • /
    • 2005
  • We monitored paralytic shellfish poison (PSP) by HPLC method in shellfishes including a sea squirt, and its products produced in domestic and imported, total 35 species, 850 samples, collected at 9 cities such as Seoul, Busan, Daegu, Ulsan, Pohang, Masan, Tongyeong, Geoje and Sacheon, 10 times by month (2 times in April and May) from March to October, 2004. PSPs were detected in a few raw samples on March, and it showed highest toxic ratio $(72.9\%)$ on third week of April (51 samples toxic in total 70 samples) and decreased suddenly to $2.4\%$ on third week of May. After then, PSPs were detected in a few samples, sporadically, and disappeared after August. Most raw shellfishes in the market were safe from PSP, showing the toxicity below 1 MU/g (quarantine level 4.0 MU/g), except oyster collected on April at Masan (1.9 MU/g), blue mussel on April (1.8 MU/g) and purplish washington clam on May at Sacheon (2.1 MU/g). However, it was strongly suggested to survey and under control for the imported scallops and ark shells which showed highly toxic in the quarantine level on May, July, even September. PSP were not detectable in the all shellfish products collected on May, July and September, except 2 boiled and dried mussels contained trace amount (0.01 MU/g), and all those products were safe as below quarantine toxin level (4.0 MU/g).

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

Growth of CdSe thin films using Hot Wall Epitaxy method and their photoelectrical characteristics (HWE방법에 의한 CdSe 박막 성장과 광전기적 특성)

  • Hong, K.J.;Lee, K.K.;Lee, S.Y.;You, S.H.;Shin, Y.J.;Suh, S.S.;Jeong, J.W.;Jeong, K.A.;Shin, Y.J.;Jeong, T.S.;Kim, T.S.;Moon, J.D.;Kim, H.S.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.328-336
    • /
    • 1997
  • The CdSe thin films were grown on the Si(100) wafers by a hot wall epitaxy method (HWE). The source and substrate temperature are $600^{\circ}C$ and $430^{\circ}C$ respectively. The crystalline structure of epilayers was investigated by double crystal X-ray diffraction(DCXD). Hall effect on the sample was measured by the van der Pauw method and studied on the carrier density and mobility dependence on temperature. From Hall data, the mobility was increased in the temperature range 30K to 150K by impurity scattering and decreased in the temperature range 150k to 293k by the lattice scattering. In order to explore the applicability as a photoconductive cell, we measured the sensitivity(${\gamma}$), the ratio of photocurrent to darkcurrent(pc/dc), maximum allowable power dissipation(MAPD), spectral response and response time. The results indicated that the photoconductive characteristic were the best for the samples annealed in Cu vapor compare with in Cd, Se, air and vacuum vapour. Then we obtained the sensitivity of 0.99, the value of pc/dc of $1.39{\times}10^{7}$, the MAPD of 335mW, and the rise and decay time of 10ms and 9.5ms, respectively.

  • PDF

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF

Some Characteristics of Teflon-Thermoluminescent Dosimeters (테프론 열형광선량계(熱螢光線量計)의 특성(特性))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 1982
  • The characteristic thermoluminescence responses of Teflon thermoluminescent dosimeters to radiations have been studied by the variation of radiation qualities as well as the high dose radiations. The change in the sensitivity of TLDs for different radiation qualities were studied through not only the photon energy dependence but also the change of supralinearity on the photon energy dependence, by exposing $^{60}Co$ gamma rays, the effective X-rays of 44keV, 69keV, 108keV, and thermal neutron of 0.04 eV. The results were as the following: The TL response of $T-CaSO_4$: Dy as a function of absorbed dose was linear up to about 5 Gy, and the response beyond 5Gy was supralinear for $^{60}Co$ gamma rays. The supralinearity of T-LiF-7 became noticeably apparent more than that of $T-CaSO_4$:Dy and also the lower the LET of radiation became the higher the supralinear effects were. No supralinearity appeared for the thermal neutron irradiations equivalent to 10Gy of $^{60}Co$ gamma rays. The relative sensitivities (Rs), which depended on the doses of $^{60}Co$ gamma rays to the TLDs of T-LiF-7 and T-$CaSO_4$:Dy could be, respectively, approximated to the following empirical formula fitted by the least square method: $$R_{LiF}=1.021-0.04581\;logD+0.402(logD)^2-0.405(logD)^3,\;\;5{\times}10^3{\geq}D{\geq}1(Gy)$$ $$R_{CaSO_4}=0.976-0.3241\;logD+0.262(logD)^2-0.298(logD)^3,\;5{\times}10^3{\geq}D{\geq}1(Gy)$$.

  • PDF