• Title/Summary/Keyword: 간편형

Search Result 445, Processing Time 0.026 seconds

A Clinical Usefulness of Office Hysteroscopy (Office Hysteroscopy의 임상적 유용성)

  • Koh, Min-Whan;Lee, Tae-Hyung;Kim, Jeong-Suk;Choi, Yoon-Young;Jeong, Sang-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.81-89
    • /
    • 2005
  • Background: Hysteroscopy is considered to be the gold standard not only for visualizing the cervical canal and the uterine cavity, but also for treating many different types of benign pathologies localized to those regions. The advent and evolution of endoscopic imaging and surgery during the last two decades has added new dimensions to the armamentarium of a gynecologist to combat intrauterine lesions. Office hysteroscopy is increasingly being used as a first line investigation for abnormal uterine bleeding and other diseases involving the uterine cavity. The aim of our study is to assess the diagnostic and operative efficacy of office hysteroscopy. Materials and Methods: In our department, 140 patients underwent a hysteroscopy examination and 18 of these underwent an office based hysteroscopy examination from September 1995 to March 2005. The cases who underwent an office based hysteroscopy examination were reviewed in order to assess the clinical usefulness and significance in the management of intrauterine lesions. Results: Major indication was abnormal uterine bleeding(12 cases, 66.7%). The others were a missed IUD and infertility. The hysteroscopic findings were a normal uterine cavity(6 cases, 33.3%), IUD in situ, polyp, submucosal myoma, endometrial hyperplasia and a placenta remnant. Conclusion: Office hysteroscopy is a safe, quick and effective method for making an intrauterine evaluation. In addition, it provides immediate results, offers the capacity of direct targeted biopsies of suspicious focal lesions, and offers the direct treatment of some intrauterine conditions.

  • PDF

Development of u-Health Care System for Dementia Patients (치매환자를 위한 u-Health Care 시스템 개발)

  • Shin, Dong-Min;Shin, Dong-Il;Shin, Dong-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1106-1113
    • /
    • 2013
  • For patients who have senile mental disorder such as dementia, quantity of excercise and amount of sunlight are important clue for dose and the treatment. Therefore, monitoring health information of daily life is necessary for patients' safety and healthy life. Portable & wearable sensor device and server configuration monitoring data are needed to provide these services for patients. Watch-type device(smart watch) which patients wear and server system are developed in this paper. Smart watch developed includes GPS, accelerometer and illumination sensor, and can obtain real time health information by measuring the position of patients, quantity of exercise and amount of sunlight. Server system includes the sensor data analysis algorithm and web server that doctor and protector can monitor through sensor data acquired from smart watch. The proposed data analysis algorithm acquires quantity of exercise information and detects step count in patients' motion acquired from acceleration sensor and to verify this, the three cases with fast pace, slow pace, and walking pace show 96% of the experimental result. If developed u-Healthcare System for dementia patients is applied, more high-quality medical service can be provided to patients.

Analysis on Surface of Seed Potato using Nano-Spectrometric Sensor (나노 분광 센서를 이용한 씨감자 표면 표현형 분석)

  • Choi, Il Soo;Oh, Jong-woo;Um, Tae-Un;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.87-87
    • /
    • 2017
  • 농산물의 품질 및 성분을 측정하는데 있어 기존의 화학적 분석 방식은 정밀도가 높으나 측정에 소요되는 시간과 비용이 많이 들어, 현장 적용하기에는 한계가 있다. 일반적으로 근적외선 분광 분석(Near Infra Red Spectroscopy, NIRS) 방법은 가공 과정에 따라 빠르게 변화되는 단백질 조성 및 수분함량 측정 등에 이용되고 있다. 분석에 소요 시간이 많이 걸리는 켈달법(Kjeldahi method)에 비해 NIR 분광 분석을 통한 보정으로 연속적인 모니터링이 가능하다. 본 연구에서 사용된 시료를 고정시키기 위한 프레임을 제작한 후 NIR센서와 광원인 LED의 각도를 고정시키고 측정 대상체인 사절된 감자 크기에 따라 시료를 고정시킬 수 있는 프레임을 반사면에 위치시켰다. 확산 반사법을 이용하여 프레임에 씨감자 시료를 고정 시킨 후 백색 LED를 이용하여 감자 표면에 빛을 반사시켜 3일 동안 12시간 마다 해당 시료들(열처리, 비누용액 침지, 생감자)의 스펙트럼을 측정하였다. 해당 시료들은 측정 기간 동안 저온상태($4^{\circ}C$)와 실온상태($20^{\circ}C$)에서 보관되었다. 실험 결과는 파장대 145nm에서 저온상태에서 보관된 생감자는 시간경과에 따른 흡광도의 결정 계수값($r^2$)은 0.98 이었다. 이는 감자가 저온에서 생감자의 상태 변화가 일어나고 있다는 것을 의미하고 파장대 145nm에서 시간에 따른 저온상태에서 보관한 감자의 상태 변화 예측이 가능함을 의미한다. 비누용액에 침지시킨 후 실온에 보관한 감자는 시간이 경과함에 따라 파장이 증가함에 따라 흡광도가 증가하였다. 이는 감자에 들어있는 Polyphenol Oxidase 함량 변화로 갈변 현상이 일어난 것을 알 수 있다. 또한 실온에서 보관한 생감자도 시간 경과에 따라 갈변 현상이 일어났지만 용액에 침지시킨 감자보다는 갈변 현상이 36시간 이후로 발견되었다. 열처리 후 실온에서 보관한 감자의 경우에는 갈변현상이 나타나지 않았다. 저온상태에서 보관한 감자시료들 모두 갈변형상이 나타나지 않았지만, 24시간이 지난 후 용액에 침지시킨 감자는 갈변 현상이 발생되었다. 생감자와 열처리한 감자는 시간 경과에 따른 갈변현상이 일어나지 않았으므로, 감자의 갈변현상은 감자의 표면 처리 방법에 국한되지 않고 온도에 영향을 더 많이 받는다는 것을 나타내고 있다. 본 연구는 향후 감자의 품질 및 성분 측정에서 간편하게 사용될 수 있는 감자의 품질 계측 기술에 기여할 것으로 판단된다.

  • PDF

Coracoclavicular Ligament Augmentation Using TightRope® for Acute Acromioclavicular Joint Dislocation : Surgical Technique and Preliminary Results (TightRope®를 이용한 급성 견봉 쇄골 관절 탈구의 치료 : 수술 술기 및 예비 보고)

  • Cho, Chul-Hyun;Sohn, Sung-Won;Kang, Chul-Hyung;Oh, Geon-Myeoung
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.165-171
    • /
    • 2008
  • Purpose: The purpose of this study was to introduce a new surgical technique and to evaluate the preliminary results after operative treatment with using TightRope$^{(R)}$ for treating acute acromioclavicular joint dislocation. Material and Methods: We studies 10 patients who were followed up for more than 6 months after operative treatment with using an TightRope$^{(R)}$. A longitudinal incision approximately 4cm in length was made from 1cm medial to the acromioclavicular joint to the coracoid process, and then coracocalvicular ligament augmentation using TightRope$^{(R)}$ was done after splitting the deltoid. For postoperative stability, two 1.6 mm Kirschner wires were inserted temporarily across the acromioclavicular joint in all cases. The radiologic results on the serial plain radiographs and the clinical results according to the UCLA score were analyzed. Results: Radiologically, 7 cases showed anatomical reduction, 2 cases showed a slightly loss of reduction and 1 case showed partial loss of reduction. Clinically, 6 cases were excellent, 3 cases were good and 1 case was fair. Conclusion: Coracoclavicular ligament augmentation using TightRope$^{(R)}$ for treating acute acromioclavicular joint dislocation is a minimally invasive, safe procedure that provides satisfactory radiologic and clinical preliminary results. Yet the long-term results have to be analyzed to determine the final results of this procedure.

Trace impurity analysis of Cu films using GDMS: concentration change of impurities by applying negative substrate bias voltage (글로우방전 질량분석법을 이용한 구리 박막내의 미량불순물 분석: 음의 기판 바이어스에 의한 불순물원소의 농도변화)

  • Lim Jae-Won;Isshiki Minoru
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 2005
  • Glow discharge mass spectrometry(GDMS) was used to determine the impurity concentrations of the deposited Cu films and the 6N Cu target. Cu films were deposited on Si (100) substrates at zero substrate bias voltage and a substrate bias voltage of -50 V using a non-mass separated ion beam deposition method. Since do GDMS has a little difficulty to apply to thin films because of the accompanying non-conducting substrate, we have used an aluminum foil to cover the edge of the Cu film in order to make an electrical contact of the Cu film deposited on the non-conducting substrate. As a result, the Cu film deposited at the substrate bias voltage of -50 V showed lower impurity contents than the Cu film deposited without the substrate bias voltage although both the Cu films were contaminated during the deposition. It was found that the concentration change of each impurity in the Cu films by applying the negative substrate bias voltage is related to the difference in their ionization potentials. The purification effect by applying the negative substrate bias voltage might result from the following reasons: 1) Penning ionization and an ionization mechanism proposed in the present study, 2) difference in the kinetic energy of accelerated Cu+ ions toward the substrate with/without the negative substrate bias voltage.

The Time of Concentration Considering the Rainfall Intensity (강우강도를 고려한 도달시간 산정식)

  • Yoo, Dong-Hoon;Kim, Jong-Hee;Lee, Min-Ho;Lee, Sang-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.7
    • /
    • pp.591-599
    • /
    • 2011
  • The rainfall intensity is a very essential factor which must be considered for the estimation of the time of concentration. The rainfall intensity, however, is not fully considered for the estimation of the time of concentration due to the complexity of the equation of rainfall intensity. To increase accuracy of the time of concentration, the rainfall intensity and return period were included in the derivation of the time of concentration equations in this study. The equation of rainfall intensity is Sherman type and the regional coefficients were estimated from the rainfall intensity readings on the probability rainfall maps published by Ministry of Construction and Transportation. For simple calculation of rainfall intensities, the contour maps were drawn that expresses coefficients of the Sherman type equation. By substituting the Sherman type equation of rainfall intensity in the equation of the time of concentration, a relatively simple equation with no repeated calculation has been derived. From the study results, in order to include the influence of the rainfall intensity for the estimation of the time of concentration, it is highly recommended that the Sherman type equation of rainfall intensity be used. When one knows a location in Korea and a return period, he can estimate the coefficients of the rainfall intensity equation and calculate the time of concentration considering the rainfall intensity.

Development of Ultrasound Phantom for Volume Calibration (부피 측정을 위한 초음파 팬텀 개발)

  • Kim, Hye-Young;Lee, Ji-Hae;Lee, Kyung-Ja;Suh, Hyun-Suk;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.227-230
    • /
    • 2008
  • The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.

  • PDF

Fabrication of a-Si:H/a-Si:H Tandem Solar Cells on Plastic Substrates (플라스틱 기판 위에 a-Si:H/a-SiGe:H 이중 접합 구조를 갖는 박막 태양전지 제작)

  • Kim, Y.H.;Kim, I.K.;Pyun, S.C.;Ham, C.W.;Kim, S.B.;Park, W.S.;Park, C.K.;Kang, H.D.;You, C.;Kang, S.H.;Kim, S.W.;Won, D.Y.;Choi, Y.;Nam, J.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.104.1-104.1
    • /
    • 2011
  • 가볍고, 유연성(flexibility)을 갖는 박막(thin film)형 플랙서블 태양전지(flexible solar cell)는 상황에 따른 형태의 변형이 가능하여, 휴대가 간편하고, 기존 혹은 신규 구조물의 지붕(rooftop)등에 설치가 용이하여, 차세대 성장 동력 분야에서 각광받고 있다. 그러나 아직까지 플랙서블 태양전지는 제작시 열에 의한 기판의 변형, 기판 이송시 너울 현상, 대면적 패터닝(patterning) 기술 등 많은 어려움 등으로 웨이퍼나 글라스 기판에 제조된 태양전지 대비 낮은 광전환 효율을 갖는다. 따라서 본 연구에서는 플랙서플 태양전지 성능개선을 위해 3.5세대급 ($450{\times}450cm^2$) 스퍼터(sputter), 금속유기 화학기상장치 (MOCVD), 플라즈마 화학기상장치 (PECVD), 레이저 가공장치 (Laser scriber)를 이용하여 a-Si:H/a-SiGe:H 이중접합(tandem)을 갖는 태양전지를 제작하였고, 광 변환효율 특성을 평가하였다. 전도도(conductivity), 라만(Raman)분광 및 UV/Visible 분광 분석을 통하여 박막의 전기적, 구조적, 광학적 물성을 평가하여 단위박막의 물성을 최적화 했다. 또한 제작된 태양전지는 쏠라 시뮬레이터 (Solar Simulator)를 이용하여 성능 평가를 수행하였고, 상/하부층의 전류 정합 (current matching)을 위해 외부양자효율 (external quantum efficiency) 분석을 수행하였다. 제작된 이중접합 접이식 태양전지로 소면적($0.25cm^2$)에서 8.7%, 대면적($360cm^2$ 이상) 8.0% 이상의 효율을 확보하였으며, 성능 개선을 위해 대면적 패턴 기술 향상 및 공정 기술 개선을 수행 중이다.

  • PDF

Development of Switching and Heating Devices in Embedded Rack Track for Environmental-friendly Mountain Railway (친환경 산악철도 매립형 궤도의 선로전환기 및 히팅장치 개발)

  • Seo, Sung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.503-510
    • /
    • 2020
  • Eco-friendly mountain railways operate on concrete rack tracks embedded on existing sharp curved and steep roads to preserve the environment in mountainous areas. Owing to the narrow roads, single lines are inevitable, and many branches are required. In branches, previous switchers and heating devices cannot be applied, because of the limited spacing for the rack and the slow removal of thick ice. To solve these problems, a switch and a heating device have been developed. The switcher changes the line by moving the block of concrete track with hydraulic actuators. The lack of discontinuity reduces the derailment risk and makes locking simple. The heating device uses high frequency induction coils to increase the efficiency and melt the thick ice rapidly. The prototype switcher and heating device were produced and operated to prove their performance. The heating device yielded a 10 times greater efficiency than the previous one. The switcher and heating device are the essential core technologies for the operation of mountain trams in winter and contribute to the spread of mountain railways to domestic or foreign resort areas by enhancing safety and efficiency. In addition, they can provide transportation rights to local residents in poor winter traffic, and bring about tourism and local economic growth.

Influence of $Ca^{++}$ Treatment on Growth and Mineral Elements of Cool-Season Turfgrass Species ($Ca^{++}$ 처리가 한지형 잔디의 생육 및 무기성분 함량에 미치는 영향)

  • Kim, Seong-Kyoo;Kang, Hoon;So, In-Sup
    • Asian Journal of Turfgrass Science
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • The influence of calcium on the growth of creeping bentgrass 'Penn-Al', perennial ryegrass 'Palmer II', Kentuckuy bluegrass 'Nassou' and tall fescue 'Boonsai 2000' in greenhouse was investigated. Creeping bentgrass 'Penn-A1', Kentucky bluegrass 'Nassou' and tall fescue 'Boonsai 2000' at Ca 4.0 me/L, and perennial ryegrass 'Palmer II' at Ca 2.0 me/L showed the best shoot growth. Creeping bentgrass 'Penn-A1', perennial ryegrass 'Palmer II' and Kentucky bluegrass 'Nassou' at Ca 1.0 me/L, and tall fescue 'Boonsai 2000' at Ca 4.0 me/L showed the best root growth, and there was little or no difference between different Ca concentrations. Creeping bentgrass 'Penn-Al' and Kentucky bluegrass 'Nassou' at Ca 4.0 mea, and perennial ryegrass 'Palmer II' at Ca 1.0 me/L had the highest number of tillers, and tall fescue 'Boonsai 2000' at Ca 4.0 me/L had the highest, but there was no difference between different Ca concentrations. As application rate of Ca concentration became higher, the concent of Ca in plant tissue increased, while the content of Mg in plant tissue decreased, and the content of Fe in plant tissue increased to Ca 4.0 me/L. The Ca treatment had not effect on N, p, K, and Zn of tissue content. The wick pot applied will be to research of plant nutrition in future because utilization of wick pot has an excellent precision and convenience.