• Title/Summary/Keyword: 간섭온도

Search Result 210, Processing Time 0.032 seconds

Performance Analysis of TPMS Beamformer According to Variance of Antenna Interelement Spacing (안테나 간격 변화에 대한 TPMS 빔형성기 성능분석)

  • Choi, Byung-Sang;Kim, Seong-Min;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.6
    • /
    • pp.907-915
    • /
    • 2013
  • Tire Pressure Monitoring System (TPMS) is an auxiliary safety system for recognizing the condition of tires based on the pressure and temperature data transmitted from the sensor unit installed on a tire of the vehicle. Using TPMS, a driver can frequently check the state of tires and it aids to maintain the optimum running condition of the vehicle. Since TPMS must utilize the wireless communication technique to transmit data from a sensor unit to a signal processing unit installed in the vehicle, it suffers from interference signals caused by various external electrical or electronic devices. In order to suppress high-power interference signals, we employ beamforming techniques based on the uniform linear antenna array. As the number of the antennas is increased, the performance of the interference suppression is improved. However, there is the limit of the number of antennas, installed in the center of a vehicle, because of its size. In this paper, we compare and analyze the performance of the beamformer, when reducing the interelement spacing of antennas, to increase the number of the receiving antennas. For the performance analysis of the beamformers, we consider the switching beamformer and minimum-variance distortionless-response (MVDR) beamformer for TPMS, recently proposed.

Optical Current Sensors with Improved Reliability using an Integrated-Optic Reflective Interferometer (반사형 간섭계를 이용하여 신뢰성을 향상시킨 광전류센서)

  • Kim, Sung-Moon;Chu, Woo-Sung;Oh, Min-Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.17-23
    • /
    • 2017
  • Optical current sensors are suitable for operation in high voltage and high current environments such as power plants due to they are not affected by electromagnetic interference and have excellent insulation characteristics. However, as they operate in a harsh environment such as large temperature fluctuation and mechanical vibration, high reliability of the sensor is required. Therefore, many groups have been working on enhancing the reliability. In this work, an integrated optical current sensor incorporating polarization-rotated reflection interferometer is proposed. By integrating various optical components on a single chip, the sensor exhibits enhanced stability as well as the solution for low-cost optical sensors. Using this, we performed the characterization for the actual field application. By using a large power source, the current of 0.3 kA~36 kA was applied to the photosensor and the linear operation characteristics were observed. The error of the sensor was within $0{\pm}.5%$. Even when operating for a long time, the error range of the sensor was kept within $0{\pm}.5%$. In addition, the measurement of the frequency response over the range of 60 Hz to 10 kHz has confirmed that the 3-dB frequency band of the proposed OCT is well over 10 kHz.

A Study on the Magnetic Properties of High $T_c$ Superconductor <$Y_{1-X}Sm_{X}Ba_{2}Cu_{3}O_{7-y}$ (고온초전도체 $Y_{1-X}Sm_{X}Ba_{2}Cu_{3}O_{7-y}$의 자기적 성질 연구)

  • Kim, Chae-Ok;Kim, Jae-Uk;Kim, Ui-Hun;Na, Hun-Gyun
    • Korean Journal of Materials Research
    • /
    • v.2 no.3
    • /
    • pp.197-201
    • /
    • 1992
  • The temperature dependence of the magentic moment was determined for the system of high $T_{c}$ superconductor $Y_{1-X}Sm_{x}Ba_2Cu_3O_{7-y}$ with x=0, 0.2, 0.4, 0, 6, 0.8 and 1.0. Also the magnetic susceptibility and the magnetic critical current density were measured from the magnetic hysterisis loops obtained at 30 K. From the results of the magnetic susceptibility measurements, the high $T_{c}$ phase were ranged from 14.7 to 49.1%. The values of the magnetic critical current densities were in the range of $10^3~10^4A/cm^2$. The penetration depth was approximately ninety times larger than the coherence length.

  • PDF

Magnetic Properties of the $Y_{1}Ba_{2}Cu_{3-x}Sn_{x}O_{7-y}$ $High-T_{C}$ Superconductor (고온 초전도체 $Y_{1}Ba_{2}Cu_{3-x}Sn_{x}O_{7-y}$의 자기적 특성 연구)

  • 이성규;이주일;김문석;유성초;임우영;백종성
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.15-21
    • /
    • 1991
  • The magnetic properties of the $Y_{1}Ba_{2}Cu_{3-x}Sn_{x}O_{7-y}$ superconductor were studied as a function of Sn concentration by utilizing both the vibrating sample magnetometer (VSM) and torque magnetometer. Unlike the cases where Fe and Co were substituted for Cu, the superconducting transition temperature was maintained above 90 K until x reached the value of 0.36. The lower critical field $H_{c1}(T)$ and upper critical field $H_{c2}(T)$ are measured as a function of temperature and external magnetic field, respectively. By aid of these results, $H_{c1}(0)$.($H_{c2}(0)$), the coherence length ${\varepsilon}_{0}$, the penetration depth ${\lambda}_{0}$, and the Ginzburg-Landau parameter k were oqtained. Flux pinning was also observed in the sample.

  • PDF

Studies on the Synthesis and Magnetic Properties of Cobalt Nanoparticles in the Polymer Film (코발트 나노 입자가 도입된 초상자성 고분자 박막의 제조 및 자성 연구)

  • Kim, Y.;Yoon, M.;Kim, Y.M.;Volkov, V.;Park, I.W.;Song, H.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.2
    • /
    • pp.59-63
    • /
    • 2003
  • Superparamagnetic properties of self-aggregated cobalt nanoparticles in the perfluorinated ion-exchange polymeric membrane (MF-4SK) prepared by ion-exchange and recovery methods were investigated by transmission electron microscopy (TEM) and superconducting quantum interference device (SQUID) magnetometer at various temperatures. Our experimental results show that cobalt nanoparticles in MF-4SK for the concentration of $7.8{\times}10^{19}$ atoms per 1 g of polymer membrane exhibit superparamagnetic properties above the average blocking temperature ($T_{B}$), which is determined to be around 185 K at applied field of 500 Oe. The average particle radius of 4.0 nm achieved from Langevin function fit is in good agreement with TEM observations. This experimental evidence suggests that cobalt nanoparticles in polymer film obey a single domain theory. The results are discussed in the light of current theory for the superparamagnetic behavior of magnetic nanoparticles.

Numerical Study on the Characteristics of Thermal Plasmas Disturbed by Inserting a Langmuir Probe (랑뮤어 탐침에 의해 변형된 열플라즈마 특성에 관한 해석적 연구)

  • Lee, J.C.;Kim, Y.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Measurements with a Langmuir probe, which are the most often used procedures of plasma diagnostics, can disturb plasma flows and change its characteristics quite a little because the probe should be inserted into thermal flowing plasmas. In this study, we calculated the characteristics of thermal plasmas with and without the probe into an atmospheric argon free-burning arc numerically, and investigated aerodynamic and thermal disturbances with temperature and axial velocity distributions. For the modelling of thermal plasmas, we have made two governing equations, which are on the thermal-flow and electromagnetic fields, coupled together with a commercial CFD package and user-coded subroutines. It was found that thermal disturbances happened to both sides of the probe, before and behind, seriously. Due to the aerodynamic disturbance, we could find that there were the stagnation point in front of the probe and the wake behind it. Therefore, aerodynamic and thermal disturbances caused by the probe insertion should be considered to increase the reliability of the probe diagnostics.

The Effect of Gas Thermochemical Model on the Flowfield of Supersonic Rocket in Propulsive Flight (기체 열화학 모델이 연소 비행하는 초음속 로켓 유동장에 미치는 영향)

  • 최환석
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.1
    • /
    • pp.12-20
    • /
    • 2002
  • An integrated analysis of kerosine/LOX based KSR-III rocket body/plume flowfield has been performed. The analysis has been executed employing three kind of gas thermo-chemical models including calorically perfect gas, multiple species chemically reacting gas, and chemically frozen gas models and their effect on rocket flowfield has been accessed to provide the most appropriate gas thermo-chemical model which meets a specific purpose of performing rocket body and plume analysis. The finite-rate chemically reacting flow solution exhibited higher temperature throughout the flowfield than other gas models due to the increased combustion gas temperature caused by the chemical reactions within the nozzle. All the reactions were dominated only in the shear layer and behind the barrel shock reflection region where the gas temperature is high and the effect of finite-rate chemical reactions on the flowfield was found to be minor. However, the present plume computation including finite-rate chemical reactions revealed major reactions occurring in the plume and their reaction mechanisms and as well.

단일 이온 빔 증착법을 이용한 $MgF_2$$ZrO_2$ 박막의 제조

  • 강종석;강성건;김홍락;김동수;김광일
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.150-150
    • /
    • 1999
  • 재료의 광학적 특성을 변화시키기 위한 표면 코팅의 사용을 잘 알려져 있다. 그리고 이러한 광학 코팅은 우리가 주위에서 볼 수 있는 렌즈에서부터 레이저반사경 다 나아가 다양한 광학 필터에 이르기까지 빛의 간섭을 이용한 광학 박막의 코팅은 폭넓게 이용되고 있다. 그러한 응용가운데 불필요한 표면 반사를 방지함으로써 전체 투과율을 강화시키기 위한 무반사(Anti-Reflection) 코팅은 오늘날 광대역 무반사 특성 등 다양한 광학적 요구에 따라 하나 또는 그 이상의 층을 형성함으로써 극적으로 성취할 수 있다. 본 실험은 기존 많이 활용되는 증발법 그리고 스퍼터링 방법과는 달리 고진공하에서 증착 변수를 효과적으로 제어, 박막을 형성할 수 있는 자체 제작된 단일 IBS(Ion Beam Sputtering) 시스템을 이용하여 우수한 광학적 특성을 갖는 광학 재료로써 무반사용 다층박막 형성하기 앞서 MgF2, ZrO2 (yttria stabilized zirconia) 단층 박막을 제조하였으며, 각 증착 변수에 따른 결정학적 및 광학적 특성을 관찰하였다. 본 실험에 사용된 제조 장비로 Kaufman type 2.5inch의 이온 건이 장착된 Ion Beam sputtering 시스템으로 초기 진공도는 5$\times$10-6orr이며, 이온 빔의 전류 밀도는 Fareday cup을 이용했다. 6inch 크기의 ZrO2(yttria stabilized zirconia), MgF2 타겟트를 이용하여 Si(100), glass 기판위에 박막을 성장시켰다. 각 타겟트에 대한 증착변수로 이온 에너지, 기판온도, Ar 가스량을 변화시키면서 박막을 제조하였다. 제조된 박막의 광학적 특성으로 가시 영역에서 투과율의 변화는 자외/가시광선 분광 분석기 (UV/VIS specrophotometer)를 이용하여 측정했다. 그리고 박막의 조성 및 결정학적 구조는 AES EDS와 XRD로 확인하였다. 이온 빔 전압 500V, 빔 저류 55mA일 때 온도는 상온에서 30$0^{\circ}C$까지 승온 후 MgF2 박막의 XRD분석결과 우세한 결정성을 관찰할 수 없었으며, 이 때의 광 투과도는 가시영역에서 80~90%의 값으로 측정되었다. 추후 증착된 막의 결정성을 위해 열처리를 실시하고, 각 증착조건에 대한 결과는 학회 발표시 보고한다.

  • PDF

A Study on the Error Rate of Non-destructive Rebar Detection Under Different Environmental Factors (환경적 요인에 따른 비파괴 철근 탐사의 오차율에 관한 연구)

  • Kang, Beom-Ju;Kim, Young-Hwan;Kim, Young-Min;Park, Kyung-Han;Oh, Hong-Seob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.506-513
    • /
    • 2021
  • The durability and safety of reinforced concrete structures significantly depend on the reinforcement conditions, concrete cover thickness, cracks, and concrete strength. There are two ways to accurately determine the information on reinforcing bars embedded in concrete - the local destructive method and the non-destructive rebar detection test. In general, the non-destructive rebar detection tests, such as the electromagnetic wave radar method, electromagnetic induction method, and radiation method, are adopted to avoid damage to the structural elements. The moisture content and temperature of concrete affect the dielectric constant, which is the electrical property of concrete, and cause interference in the non-destructive rebar detection test results. Therefore, in this study, the effects of the electromagnetic wave radar method and electromagnetic induction method have been analyzed according to the temperature and surface moisture content of concrete. Due to the technological advancement and development of equipment, the average error rate was less than 5% in the specimens at 24℃, irrespective of their operating principles. Among the tested methods, the electromagnetic induction method showed very high accuracy. The electromagnetic wave radar method indicated a relatively small error rate in the dry state than in the wet state, and exhibited a relatively high error rate at high temperatures. It was confirmed that the error could be reduced by applying the electromagnetic wave radar method when the temperature of the probe was low and in a dry state, and by using the electromagnetic induction method when the probe was in a wet state or at a high temperature.

A STUDY ON TEMPERATURE VARIATION OF THE UPPER THERMOSPHERE IN THE HIGH LATITUDE THROUGH THE ANALYSIS OF 6300 $\AA$ AIRGLOW DATA (6300 $\AA$ 대기광 자료 분석을 통한 고위도 열권 상부에서의 온도 변화)

  • 정종균;김용하;원영인;이방용
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.94-108
    • /
    • 1997
  • The temperature of the upper thermosphere is generally varied with the solar activity, and largely with geomagnetic activity in the high latitude. The data analyzed in this study are acquired at two ground stations, Thule Air Base($76,5{deg} N, 68.4{deg} W, A = 86{deg}$) and $S{psi}ndre Str{psi}mfjord (67.0{deg} N, 50.9{deg} W, A = 74{deg}$), Greenland. Both stations are located in the high latitude not only geographically but also geomagnetically. The terrestrial night glow at 6300 ${angs}$ from atomic oxygen has been observed from the two ground-based Fabry-Perot interferometers, during periods of 1986~1991 in Thule Air Base and 1986~1994 in $S{psi}ndre Str{psi}mfjord$. Some features noted in this study are as follows: (1) The correlation between the solar activity and the measured thermospheric temperature is highest in the case of $3{leq}Kp{leq}4$ in Thule, and increases with the geomagnetic activity in $S{psi}ndre Str{psi}mfjord$. (2) The measured temperatures at Thule is generally higher than those at $S{psi}ndre Str{psi}mfjord$, but the latter shows steeper slope with the solar activity. (3) The harmonic analysis shows that the diurnal variation(24hrs) is the main feature of the daily temperature variation with a temperature peak at about 13-14 LT (LT=UT-4). However, the semi-diurnal variation is evident during the period of weak solar activity. (4) Generally the predicted temperatures from both MSIS86 and VSH models are lower than the measured temperature, and this discrepancy grows as the solar activity increases. Therefore, we urge modelers to develope a new thermospheric model utilizing broader sets of measurements, especially for high solar activity.

  • PDF