• Title/Summary/Keyword: 간동맥 화학색전술

Search Result 23, Processing Time 0.016 seconds

Radiation Therapy for Hepatocellular Carcinoma with Portal Vein Tumor Thrombosis (간문맥종양혈전증을 동반한 간세포암에서의 방사선 치료)

  • Park, Seung-Gyu;Kim, Jin-Hee;Byun, Sang-Jun;Kim, Ok-Bae;Hwang, Jae-Seok;Oh, Young-Kee;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • Purpose: To evaluate the effectiveness of radiation therapy (RT) for hepatocellular carcinoma (HCC) with portal vein tumor thrombosis (PVTT) and to analyze the prognostic factors. Materials and Methods: From December 2004 to April 2009, 70 patients who had HCC with PVTT were treated with RT at Keimyung University Dongsan Medical Center. Nineteen patients whose total dose was below 30 Gy and one patient who underwent liver transplantation were excluded. The remaining 50 patients (45 males, 5 females; median age 55 years) were analyzed. According to the LCSGJ TNM stage, there were 27 patients (54.0%) with stage III and 23 (46.0%) with stage IV. Total dose of 30~54 Gy was administered (median 45). Thirty patients (60.0%) were treated with concurrent chemoradiation therapy (CCRT). The median follow-up duration was from 13.5 months (range, 3 to 70 months). Results: The median survival time from the start of RT was 9 months. One-year and 2-year overall survival rates were 24.9% and 11.2%, respectively. At the follow-up time, three patients (6.0%) displayed no evidence of disease. Seven patients (14.0%) were alive with disease, and 40 (80.0%) patients had expired due to disease progression. CCRT was associated with worse survival than RT alone (p=0.034), Response to RT (p=0.037), CLIP stage (p=0.017), and TNM stage (p=0.041) were statistically significant prognostic factors. There was no radiation-induced liver disease. Conclusion: RT is an effective and safe modality for HCC with PVTT. Further studies such as prospective randomized trials are needed to confirm the role of RT for HCC with PVTT.

Long-term Outcome of Glycogen Storage Disease Type 1; Analysis of Risk Factors for Hepatic Adenoma (당원병 제1형의 장기 추적 관찰; 간선종 발생의 위험 요인에 대한 연구)

  • Yang, Hye-Ran;Seo, Jeong-Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2003
  • Purpose: The aim of the study was to evaluate the long-term outcome of glycogen storage disease (GSD) type 1 with particular reference to hepatic adenoma and hepatocellular carcinoma, and to analyze risk factors affecting the development of hepatic adenoma in GSD type 1. Methods: Forty-three GSD type 1 patients (31 males and 12 females, mean age $13.9{\pm}6.4$ years) were analyzed retrospectively. Hepatic adenoma was detected on abdominal USG and diagnosed on histologic examination. Clinical profiles were compared between patients with hepatic adenoma (n=16) and age-matched controls without hepatic adenoma (n=16). Results: 1) Of 43 GSD type 1 patients, 16 (37.2%) had hepatic adeoma. Hepatic adenoma was detected at the age of mean $14.2{\pm}4.1$ years (range: 7.9~25.7 years). Fourteen (87.5%) adenomas were multiple at detection. 2) Comparison of the clinical profiles between adenoma group and non-adenoma group revealed that age at first introduction of uncooked cornstarch treatment was significantly late in adenoma group compared with non-adenoma group ($9.1{\pm}5.2$ years vs. $3.0{\pm}1.8$ years, p=0.003). Portocaval shunt surgery was performed in 11 (68.8%) patients in adenoma group and 3 (18.8%) in non-adenoma group (p=0.004). Hepatic adenoma developed mean $5.8{\pm}4.2$ years after shunt operation. 3) One patient was diagnosed as hepatocellular carcinoma at the age of 25.7 years. Conclusion: Hepatic adenoma is an important late complication of GSD type 1 with the risk of malignant transformation. Early introduction of cornstarch therapy with strict metabolic control is needed to prevent the development of hepatic adenoma in GSD type 1.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.