• Title/Summary/Keyword: 가정용 가습기

Search Result 10, Processing Time 0.019 seconds

Basic Analysis of Heat and Mass Transfer Characteristics of Tubular Membrane Humidifier for Proton Exchange Membrane Fuel Cell (이온교환막 연료전지용 원통형 막 가습기의 열 및 물질전달특성 기초 연구)

  • Bae, Ho-June;Ahn, Kook-Young;Lee, Young-Duk;Kang, Sang-Kyu;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.473-480
    • /
    • 2011
  • The proton exchange membrane (PEM) fuel cell system is critically dependent on the humidity, which should be properly maintained over the entire operating range. A membrane humidifier is used for the water management in the PEMFC because of the membrane humidifier's reliable performance and zero parasitic power loss. In the PEMFC system, the membrane humidifier is required to provide appropriate humidity for the design point of the fuel cell. Although the performance of the fuel cell depends on the performance of the humidifier, few studies have provided a systematic analysis of the humidifier. We carry out an experimental analysis of the membrane humidifier using a vapor condensation bottle. The dry air pressure, water flow temperature, and air flow rate were chosen as the operating parameters. The results show that the time constant for the dynamic response of the membrane humidifier is relatively short, but additional analysis should be carried out.

Two Visualization Techniques Using Smoke-wire and Micro Water-droplets and Their Applications to Vortex Flows (연기선과 미세 수적을 이용한 두 가지 가시화 기법과 와류에의 적용)

  • Sohn, Myong Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1017-1026
    • /
    • 2016
  • The present paper describes the two off-surface visualization techniques and their application examples to vortex flows. One of the two visualization techniques is the classical smoke-wire technique, and the other is the visualization technique using the micro water-droplets generated by the home-style ultrasonic humidifier. The smoke-wire technique has the limit of air flow speed (about 5 m/sec for 0.07 mm-diameter wire) and the pollution problem, but it produces very fine and clear streak line sheet. It is applied to visualize the wing-tip vortices of a 3-dimensional wing. The micro water-droplet technique has the larger limit of air flow speed (above 10 m/sec) and is free from pollution and toxic problems compared to the smoke-wire technique. It is successfully applied to visualize the complex vortex system of a double-delta wing with an apex strake.

Optimization for the Humidification Performance of a Residential Rotor-Type Humidifying Element (가정용 로터식 가습 소자의 가습 성능 최적화)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.7-13
    • /
    • 2017
  • A comfortable indoor environment is important considering that many hours are spent in residential or office space. A humidifier is used to control the indoor humidity. In particular, an element type humidifier has the advantage of a simple structure and low energy consumption. Two types of humidifiers - stationary or rotor - are commonly used for residential purposes. In this study, performance optimization was conducted for a rotor-type humidifying element used in a residential humidifier. The optimization included the rotation speed, water submersion depth, etc. The test range consisted of an open area to the air from 57 to 90%, rotation speed from 0.2 to 2.0 rpm, frontal air velocity from 0.5 to 2.5 m/s. The results showed that the optimal open area to air was 70%. On the other hand, the effects of the rotation speed on the moisture transfer rate was negligible. On the other hand, the pressure drop increased with increasing rotation speed. As the frontal air velocity increased, both the moisture transfer rate and pressure drop increased. The humidification capacity of the present element was 0.08 ~ 0.31 kg/hr. A comparison of the data with the theoretical results was made.

Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier (초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구)

  • Kim, Seunga;Kim, Jihyun;Lee, Minjoo;Kim, Jayun;Jung, Woosik;Park, Joonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

Residential Humidifying Element Made of Cellulose and PET Composite (셀룰로오스와 PET 복합체로 만들어진 가정용 가습소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.13-18
    • /
    • 2016
  • Humidifiers are used to control indoor humidity. Element-type humidifiers have the advantages of simple structure and low energy consumption, and Japanese products have been widely used for the humidifying elements. In this study, a new humidifying element made of cellulose and PET was developed, and the performance was compared with that of a Japanese element. The mass transfer rates and pressure drops were measured for an element installed at the entrance of a suction-type wind tunnel. The humidification efficiency of the new element was 2 to 4% greater and the pressure drop was 23 to 32% smaller compared to the Japanese element. The mass transfer effectiveness ($j_m/f$) of the new element is also 5 to 28% higher. However, the water absorption capacity was smaller than that of the Japanese element, meaning further development is needed.

A CFD Study on Unsteady and Steady State of the Hydrogen Leakage for Residential Fuel Cell System (가정용 연료전지 시스템 내부 수소 누출의 비정상 및 정상 상태에 관한 전산 해석)

  • Chung, Tae-Yong;Ahn, Jae-Uk;Nam, Jin-Hyun;Shin, Dong-Hoon;Kim, Young-Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.41-46
    • /
    • 2007
  • The residential fuel cell system was modeled as a box-shaped chamber with vent openings, filled with various components such as reformer, desulfurizer, fuel cell stack and humidifier. When the vent openings are 1% of the total surface and hydrogen leakage 1%, hydrogen concentration is around 0.1% higher than the other regions from leak points in the chamber at 30 seconds and hydrogen concentration is increased from 0.3% to 0.7% in the upper region of the system after 200 seconds. When the vent openings are 1% of the total surface and hydrogen leakage 1%, 3%, 5%, the steady state result of CFD, 5% of hydrogen leakage is reached the lowest ignition limit in the system. When the vent openings are 2% of the total surface and hydrogen leakage 1%, hydrogen concentration is increased in the bottom of the system for 60 seconds. After 250 seconds, hydrogen concentration is reached the steady state in the system. As the vent opening of the total surface increased from 1% to 2%, averaged hydrogen mole fraction is under 1% in the system, however, upper regions of the system from the hydrogen leakage points are shown over 1% of hydrogen mole fraction.

  • PDF

A STUDY ON DEVELOPING A DESIGN OF SUPERSONIC HUMIDIFIER FOR HOME USE. - With a focus on 3 domestic companys Household electric appliances - (가정용 초음파 가습기 디자인개발에 관한 연구 - 국내가전 3사를 중심으로 -)

  • 오성진
    • Archives of design research
    • /
    • v.6 no.1
    • /
    • pp.23-46
    • /
    • 1993
  • The development of technology in modern industrial world which grows and changes every day is shortening the cycle of life span of products, so there is a flood of products around us. It is enough to say that this phenomenon leads to further emphasis on the aspect of design for human being. It is not a new fact that to design for the rational function and the modeling from to make a combination and to satisfy consumers' desire is a short cut to gain competitive superiority in developing new products for MIS security. Therefore the design which plays a leading role in the activity of creating more convenient, more aesthetic, and more econemical products is called 'NEW CORPORATE WEAPON'. The amount of effort made for developing products is different in each company, but recently the plan to develope new products and its process arouse more interest. This thesis purports to improve objective understanding about the development of design by investigating products development research and the process of analysis and designing as a case study on developing a domestic supersonic humidifier. This thesis consists of five chapters in all. In chapter one as a preface, the purpose the method and the scope of the study is described. Chapter two contains my effort to grasp the background of study on the design and the basic structure of supersonic humidifier. Chapter three is an examination into the present conditions of supersonic humidifier used in domestic and foreign area, and the shape of design. In chapter four, a guide for the development of design is established. The idea sketch based on a fundamental shape and the drawing are added to this. In chapter five on the basis of the result of analysis in the preceding research I describe the development of design of products on the premise that marketing gives proof for them but the products oriented by manufacturer are not included in this case. In this thesis, I try to recognize the process of the develpment of design and the importance of the plan for design in developing products by examining an investigative and analytic study on the design of products.

  • PDF

A study on development of 1kW SOFC test system (1kW급 연료전지 평가시스템 개발에 관한 연구)

  • Hwang, Hyun Suk;Lee, Sanghoon;Lee, Juyoung
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.24-27
    • /
    • 2016
  • In this study, a 1kW Solid Oxide Fuel Cell(SOFC) test system was developed. A SOFC is the most promising power system to provide the higher efficient(over 50%) for house application area(1~10kW). To develop the optimized test system, the temperature control module that controls the preprocess and reaction condition, the flow control module that controls of the mass of reactants, and the electric loader that tests the discharge performance condition, etc. The temperature control module was designed to provide the high control resolution(under $1^{\circ}C$ at $750^{\circ}C$ of operating temperature) using K-type thermal couple. The flow control module was designed control blower and heater precisely using the phase control method. And the electric loader is designed that provide CV, CC, CR discharge mode and minimized the operating error adopting the independent DC-DC converter on analog input and output module. The performance of the developed SOFC test system showed that the accuracy of stack voltage was 0.15% at 80V and stack current was 0.1% at 100A.

Characteristics of Bioaerosol Generation of Household Humidifiers by User Practices (가정용 가습기의 사용자 습관에 따른 실내공기 중 바이오에어로졸의 발생특성)

  • Kim, Ik-Hyeon;Kim, Ki Youn;Kim, Daekeun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.503-509
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate the generation characteristics of airborne bacteria and fungi while operating a household humidifier, in consideration of user habits. Methods: Microbial samples were collected in a closed chamber with a total volume of 2.76 $m^3$, in which a humidifier was operated according to experimental strategies. A cultivation method based on the viable counts of mesophilic heterotrophic bacteria and fungi was performed. Experimental strategies were divided into three classes: the type of water in the water reservoir (tap water, cooled boiled water); the frequency of filling the reservoir (refill every day, no refill); and the sterilization method (sterilization function mode, humidifier disinfectants). Results: Significant increases in the concentration of airborne bacteria were observed while the humidifier was in operation. The concentration had increased to 2,407 $CFU/m^3$ by 120 hours when tap water filled the reservoir without any application of sterilization, while for cooled boiled water, it was merely 393 $CFU/m^3$ at a similar time point. Usages of disinfectant in the water tank were more effective in decreasing bioaerosol generation compared to sterilization function mode operation. Generation characteristics of airborne fungi were similar to those of bacteria, but the levels were not significant in all experiments. Calculated exposure factor can be used as an indicator to compare biorisk exposure. Conclusion: This study identified the potential for bioaerosol generation in indoor environments while operating a household humidifier. User practices were critical in the generation of bioaerosol, or more specifically, airborne bacteria. Proper usage of a humidifier ensures that any biorisks resulting from generated bioaerosol can be prevented.

Investigation of Vortical Flow Field Visualization by Micro Water Droplet and Laser Beam Sheet (미세수적과 레이저 평면광에 의한 와류장의 가시화 연구)

  • 이기영;손명환
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • A new off-surface visualization method of using the micro water droplet and laser beam sheet was presented. About a size of 5 to TEX>$10\mu\textrm{m}$ micro water droplet could be made from home-style ultrasonic humidifier, A 3 W Argon ion laser and cylindrical lens were used to generate a laser beam sheet, which interrogate specific cross section of the vortical flow field. Application of this new visualization method was conducted in KAFA small-sized low speed wind tunnel of having the test section of 0TEX>$0.9 m(W){\times}$0.9 m(H){\times}2.1 m(L)$$$. Visualization results show this method relatively easy and safe flow visualization method for wind tunnel testing. Moreover, this method is also make up for the disadvantage of smoke visualization, and can be applied to higher flow velocity range than that of smoke visualization.