• Title/Summary/Keyword: 가이드 조건

Search Result 255, Processing Time 0.029 seconds

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

Development and Validation of an Analytical Method for Determination of Fungicide Tridemorph in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 tridemorph의 시험법 개발 및 검증)

  • Pak, Won-Min;Do, Jung-Ah;Lim, Seung-Hee;Park, Shin-Min;Yoon, Ji-Hye;Lee, Dong-seouk;Chang, Moon-Ik
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.290-297
    • /
    • 2017
  • The purpose of this study was developed for the determination of tridemorph in agricultural commodities samples. Tridemorph residues in samples were extracted with acetonitrile, partitioned with saline water, and then purified using and aminopropyl ($NH_2$) SPE catridge. The purified samples were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~2.5 ng) into a blank extract with $r^2$ > 0.999. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. The average recovery ranged between 75.9% and 103.7% at different concentration levels (LOQ, 10 LOQ, 50 LOQ, n = 5) with relative standard deviations (RSDs) less than 9.0%. An interlaboratory study was conducted to validate the method by Korea Advanced Food Research Institute. The average recovery ranged between 87.0% and 109.2% at different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$, n = 5) with relative standard deviations (RSDs) less than 8.0%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL40, 2003) and Food Safety Evaluation Department guidelines (2016). The results prove that the developed analytical methods is accurate, effective and sensitive for tridemorph determination.

Development and Validation of an Analytical Method for Fungicide Sedaxane Determination in Agricultural Products using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Sedaxane의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Park, Shin-Min;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.30-39
    • /
    • 2019
  • An analytical method was developed for the determination of sedaxane in agricultural products using liquid chromatograph-tandem mass spectrometry (LC-MS/MS). The samples were extracted with acetonitrile and partitioned with dichloromethane to remove the interference, and then purified by using silica SPE cartridges to clean up. The analytes were quantified and confirmed by using LC-MS/MS in positive ion mode using multiple reaction monitoring (MRM). The matrix-matched calibration curves were linear over the calibration ranges ($0.001-0.25{\mu}g/mL$) into a blank extract with $r^2$>0.99. For validation, recovery tests were carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ, n=5) with five replicates performed at each level. The recoveries were ranged between 74.5 to 100.8% with relative standard deviations (RSDs) of less than 12.1% for all analytes. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40, 2003) and Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for sedaxane determination in agricultural commodities.

Development and Validation of a Simultaneous Analytical Method for 5 Residual Pesticides in Agricultural Products using GC-MS/MS (GC-MS/MS를 이용한 농산물 중 잔류농약 5종 동시시험법 개발 및 검증)

  • Park, Eun-Ji;Kim, Nam Young;Shim, Jae-Han;Lee, Jung Mi;Jung, Yong Hyun;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.228-238
    • /
    • 2021
  • The aim of this research was to develop a rapid and easy multi-residue method for determining dimethipin, omethoate, dimethipin, chlorfenvinphos and azinphos-methyl in agricultural products (hulled rice, potato, soybean, mandarin and green pepper). Samples were prepared using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) and analyzed using gas chromatography-tandem mass spectrometry (GC-MS/MS). Residual pesticides were extracted with 1% acetic acid in acetonitrile followed by addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. The extracts were cleaned up using MgSO4, primary secondary amine (PSA) and octadecyl (C18). The linearity of the calibration curves, which waas excellent by matrix-matched standards, ranged from 0.005 mg/kg to 0.3 mg/kg and yielded the coefficients of determination (R2) ≥ 0.9934 for all analytes. Average recoveries spiked at three levels (0.01, 0.1, 0.5 mg/kg) and were in the range of 74.2-119.3%, while standard deviation values were less than 14.6%, which is below the Codex guideline (CODEX CAC/GL 40).

Investigation and Processing of Seismic Reflection Data Collected from a Water-Land Area Using a Land Nodal Airgun System (수륙 경계지역에서 얻어진 육상 노달 에어건 탄성파탐사 자료의 고찰 및 자료처리)

  • Lee, Donghoon;Jang, Seonghyung;Kang, Nyeonkeon;Kim, Hyun-do;Kim, Kwansoo;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.603-620
    • /
    • 2021
  • A land nodal seismic system was employed to acquire seismic reflection data using stand-alone cable-free receivers in a land-river area. Acquiring reliable data using this technology is very cost effective, as it avoids topographic problems in the deployment and collection of receivers. The land nodal airgun system deployed on the mouth of the Hyungsan River (in Pohang, Gyeongsangbuk Province) used airgun sources in the river and receivers on the riverbank, with subparallel source and receiver lines, approximately 120 m-spaced. Seismic data collected on the riverbank are characterized by a low signal-to-noise (S/N) and inconsistent reflection events. Most of the events are represented by hyperbola in the field records, including direct waves, guided waves, air waves, and Scholte surface waves, in contrast to the straight lines in the data collected conventionally where source and receiver lines are coincident. The processing strategy included enhancing the signal behind the low-frequency large-amplitude noise with a cascaded application of bandpass and f-k filters for the attenuation of air waves. Static time delays caused by the cross-offset distance between sources and receivers are corrected, with a focus on mapping the shallow reflections obscured by guided wave and air wave noise. A new time-distance equation and curve for direct and air waves are suggested for the correction of the static time delay caused by the cross-offset between source and receiver. Investigation of the minimum cross-offset gathers shows well-aligned shallow reflections around 200 ms after time-shift correction. This time-delay static correction based on the direct wave is found essential to improving the data from parallel source and receiver lines. Data acquisition and processing strategies developed in this study for land nodal airgun seismic systems will be readily applicable to seismic data from land-sea areas when high-resolution signal data becomes available in the future for investigation of shallow gas reservoirs, faults, and engineering designs for the development of coastal areas.

Improvement of an Analytical Method for Methoprene in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 살충제 메토프렌의 잔류분석법 개선)

  • Park, Eun-Ji;Kim, Nam Young;Park, So-Ra;Lee, Jung Mi;Jung, Yong Hyun;Yoon, Hae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • The research aims to develop a rapid and easy analytical method for methoprene using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A simple, highly sensitive, and specific analytical method for the determination of methoprene in livestock products (beef, pork, chicken, milk, eggs, and fat) was developed. Methoprene was effectively extracted with 1% acetic acid in acetonitrile and acetone (1:1), followed by the addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. Subsequently, the lipids in the livestock sample were extracted by freezing them at -20℃. The extracts were cleaned using MgSO4, primary secondary amine (PSA), and octadecyl (C18), which were then centrifuged to separate the supernatant. Nitrogen gas was used to evaporate the supernatant, which was then dissolved in methanol. The matrix-matched calibration curves were constructed using 8 levels (1, 2.5, 5, 10, 25, 50, 100, 150 ng/mL) and the coefficient of determination (R2) was above 0.9964. Average recoveries spiked at three levels (0.01, 0.1, and 0.5 mg/kg), and ranged from 79.5-105.1%, with relative standard deviations (RSDs) smaller than 14.2%, as required by the Codex guideline (CODEX CAC/GL 40). This study could be useful for residue safety management in livestock products.

Selection and Validation of an Analytical Method for Trifludimoxazin in Agricultural Products with LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Trifludimoxazin의 시험법 선정 및 검증)

  • Sun Young Gu;Su Jung Lee;So eun Lee;Chae Young Park;Jung Mi Lee;Inju Park;Yun Mi Chung;Gui Hyun Jang;Guiim Moon
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.3
    • /
    • pp.79-88
    • /
    • 2023
  • Trifludimoxazin is a triazinone herbicide that inhibits the synthesis of protoporphyrinogen oxidase (PPO). The lack of PPO damages the cell membranes, leading to plant cell death. An official analytical method for the safety management of trifludimoxazin is necessary because it is a newly registered herbicide in Korea. Therefore, this study aimed to develop a residual analysis method to detect trifludimoxazin in five representative agricultural products. The EN method was established as the final extraction method by comparing the recovery test and matrix effect with those of the QuEChERS method. Various sorbent agents were used to establish the clean-up method, and no differences were observed among them. MgSO4 and PSA were selected as the final clean-up conditions. We used LC-MS/MS considering the selectivity and sensitivity of the target pesticide and analyzed the samples in the MRM mode. The recovery test results using the established analysis method and inter-laboratory validation showed a valid range of 73.5-100.7%, with a relative standard deviation and coefficient of variation less than 12.6% and 14.5%, respectively. Therefore, the presence of trifludimoxazin can be analyzed using a modified QuEChERS method, which is widely available in Korea to ensure the safety of residual insecticides.

A study on the effect of ground conditions of room and pillar method on pillar and room strain (격자형 지하공간의 지반조건이 암주와 룸 변형률에 미치는 영향에 대한 연구)

  • Ham, Hyeon Su;Kim, Yong Kyu;Park, Chi Myeon;Lee, Chul Ho;Kim, YoungSeok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.577-587
    • /
    • 2021
  • Room and Pillar method is an underground facility construction method that maximizes the strength of the in-situ ground. In order to secure the safety of the underground space, it is necessary to secure the safety of the room actually used in addition to the safety of pillar of the room and Pillar method. In this study, the evaluation method for the safety of the room and rock pillar in the room and pillar method was studied through numerical analysis. Numerical analysis was performed for a total of 125 cases using ground conditions, pillar width, and room width as parameters, and the results were derived. As for the safety factor of the pillar, it was confirmed that the safety factor increased when the strength of the ground increased, and it was confirmed that the increment in the safety factor decreased when the width of the pillar was widened. The room strain was evaluated by applying the Critical strain. As the width of the pillar became narrower, the Critical strain was higher, and as the width of the room became smaller, the Critical strain was smaller. As a result of the correlation analysis between the safety factor of the pillar and the room strain, it was possible to derive the upper limit of the room strain that can secure the standard safety factor of the pillar according to the width of the pillar. It is judged that the results derived from this study can be used as a guideline to secure the safety of the room when the actual design is performed in consideration of the ground conditions and room width.

A Perception of Beginning Earth Science Teachers on Porphyritic Texture (반상조직에 대한 초임 지구과학교사들의 인식)

  • Kim, Yong-Hwan;Chung, Duk-Ho;Cho, Kyu-Seong;Choi, Jin-A;Park, Kyeong-Jin
    • Journal of the Korean earth science society
    • /
    • v.32 no.7
    • /
    • pp.860-870
    • /
    • 2011
  • This study is to explore the Pedagogical Content Knowledge of beginning earth science teachers about the porphyritic texture of igneous rocks, and to suggest the teaching device that can prevent a trial and error of students in earth science instruction. We developed an interview guideline concerned with basic perception on the porphyritic texture, formation condition and formation process of porphyritic rocks, teaching and learning on porphyritic rocks for it. And data was collected from 5 beginning earth science teachers (3 high schools, 2 middle schools) through a group discussion method. In result, despite the porphyritic texture can be found at hypabyssal rocks as well as volcano rocks and plutonic rocks, most beginning earth science teachers cognized that it could be found at hypabyssal rocks only by focusing the formation depth of hypabyssal rocks. Also, the formation of porphyritic texture should be considered the factors such as cooling rate, nucleation density, growth rate, growth time, etc. However they mainly reflected the formation temperature and growth rate as it's parameter. Participants have wrongly perceived that a phenocryst necessarily differs from a groundmass on chemical composition. And they are inclined to discriminate phenocryst from groundmass through their chemical differences, instead of grain size.

Analyzing association between low-density lipoprotein reduction by statin and adherence to medication using national health insurance service-national sample cohort (NHIS-NSC) (표본코호트기반 고지혈증 약제의 저밀도 콜레스테롤 감소량 및 투약순응도 분석)

  • Kim, Kyu-Jin;Jun, Chi-Hyuck;Lee, Hyeseon;Kim, Hun-Sung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.5
    • /
    • pp.1027-1041
    • /
    • 2017
  • Hyperlipidemia, the status of blood with high level of low-density lipoprotein cholesterol (LDL-C), is known as a main cause of coronary artery diseases such as myocardiac infarction or brain infarct. Statin is the representative prescription to hyperlipidemia and the effects of it depend on the patient's individual conditions such as health-caring habits or adherence to medication. The main effect of statin is reducing LDL-C, which should reach the target range based on National Cholesterol Education Program-Adult Treatment Panel III (NCEP-ATP III) guideline. In this research, the reduction of LDL-C and attainment to patient's target range are considered effects of statin. The association between factors - individual conditions and adherence to medication of patients - and the effects of statin is analyzed with National Health Insurance Service-National Sample Cohort (NHIS-NSC).