• Title/Summary/Keyword: 가열 벽면 수

Search Result 29, Processing Time 0.025 seconds

Experimental Study on the Heat Transfer and Turbulent Flow Characteristics of Jet Impinging the Non-isothermal Heating Plate (비균일 온도분포를 갖는 평판에 대한 충돌제트의 열전달 및 난류유동특성에 관한 연구)

  • 한충호;이계복;이충구;이창우
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.272-277
    • /
    • 2001
  • An experimental study of jet impinging the non-isothermal heating surface with linear temperature gradient is conducted with the presentation of the turbulent flow characteristics and the heat transfer rate, represented by the Nusselt number. The jet Reynolds number ranges from 15,000 to 30,000, the temperature gradient of the plate is 2~4.2$^{\circ}C$/cm and the dimensionless nozzle to plate distance (H/D) is from 2 to 10. The results show that the peak of heat transfer rate occurs at the stagnation point, and the heat transfer rate decreases as the radial distance from the stagnation point increases. A remarkable feature of the heat transfer rate is the existence of the second peak. This is due to the turbulent development of the wall jet. Maximum heat transfer rate occurs when the axial distance from the nozzle to nozzle diameter (H/D) is 6 or 8. The heat transfer rate can be correlated as a power function of Prandtl number, Reynolds number, the dimensionless nozzle to plate distance (H/D) and temperature gradient (dT/dr). It has been found that the heat transfer rate increases with increasing turbulent intensity. The wall jet is influenced by temperature gradient and the effect becomes more important at higher radii.

  • PDF

Effect of Number of Heating Walls on Heat Transfer in the Reciprocating Square Channel (왕복운동을 하는 사각채널에서 가열벽면의 수가 열전달에 미치는 효과)

  • Kim Myung Ho;Bae Sung Taek;Ahn Soo Whan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.161-167
    • /
    • 2005
  • The improvements of the propulsive engine efficiencies could reduce the fuel consumption. Therefore. for a marine main diesel engine the substantial increase of stroke bore ratio. so that the engine speed can be significantly reduced in order to increase the Propulsive efficiency. As a typical example. a Sulzer RTA 60C engine has acylinder diameter of 600 mm and each cylinder is capable of delivering 2.369 kW in the speed range 91-114 rpm. In order to Provide basic data for thermal system of marine engine. this work performs an experimental study of heat transfer in a square channel with one rib-roughened wall under sin91e mode of reciprocating oscillation. A selection of heat transfer measurements illustrates the manner by which the reciprocating channel with two opposite heating walls has the higher heat transfer Performance than with four heating wall.

Numerical Simulation for Heat Transfer and Fluid Flow in the Channel with $45^{\circ}$ Incinlined Rib ($45^{\circ}$ 경사진 거칠기가 설치된 채널에서 유체유동과 열전달에 대한 수치모사)

  • Oh, S.K.;Kang, H.K.;Kim, M.H.;Bae, S.T.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.25-33
    • /
    • 2006
  • 거칠기가 한 벽면과 두 벽면에 설치된 사각채널에서 비압축성 유체유동과 열전달을 조사하기위해 3차원 수치모사를 행하였다. CFX (version 5) software package 를 사용하여 계산하였다. 거친 벽은 $45^{\circ}$경사진 거칠기가 설치되어 있다. 채널의 4 벽면은 일정한 열 유속으로 가열하였다. 수치계산 결과는 실험값과 잘 일치 하였다. 연구의 조건은 거칠기 피치와 높이의 비가 8이고, 거칠기 높이와 채널 수력직경의 비가 0.067이며, 레이놀즈수의 범위는 7,600에서 24,900이었다. 연구의 결과는 열전달계수와 마찰계수는 사각채널에서 거친 벽면의 수가 클수록 증가 함을 보였다.

  • PDF

Effects of Number of Heating Walls on Heat Transfer in the Rough Square Channel with Twisted Tape (테이프가 있는 거친 사각채널에서 가열벽면의 수가 열전달에 미치는 효과)

  • Ahn, S.W.;Kim, M.H.;Bae, S.T.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.17-22
    • /
    • 2006
  • Surface modifications like rib-roughening and displaced insert devices like the twisted tape are commonly used in applications such as compact heat exchangers and cooling systems. In this paper, regionally averaged heat transfer distributions in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. Regionally averaged Nusselt number and channel averaged Nusselt number in turbulent air flows are presented for Reynold numbers from 8,900 to 29,000. We have obtained the following conclusions from the experimental study: 1) The local Nusselt number in the two-sided heated case is higher than that in the four-sided heated condition. 2) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 3) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer coefficient.

  • PDF

Effect of Number of Heating Walls on Heat Transfer in Ribbed Rectangular Channel (거친 사각채널에서 가열 벽면의 수가 열전달에 미치는 효과)

  • Bae Sung Taek;Ahn Soo Whan;Kim Myoung Ho;Lee Dae Hee;Kang Ho Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.514-520
    • /
    • 2005
  • Surface heat transfer of a fully developed turbulent air flow in a $45^{\circ}$ inclined ribbed square duct with two and four heating walls was experimentally investigated, at which the experimental works were peformed for Reynolds numbers ranging from 7,600 to 26,000. The pitch-to-rib height ratio, p/e, was kept at 8 and rib-height-to-channel hydraulic diameter ratio, $e/D_h$ was kept at 0.0667. The channel length-to-hydraulic diameter ratio, $L/D_h$ was 60. The heat transfer coefficient values were decreased with the increase in the number of heat-ing walls. Results of this investigation could be used in various applications of internal channel turbulent flow involving roughened walls.

Hydrocarbon Fuel Heating Experiments Simulating Regeneratively Cooled Channels of LRE Combustor (로켓엔진 연소기 재생냉각채널을 모사한 탄화수소계 연료가열시험)

  • Lim, Byoung-Jik;Lee, Kwang-Jin;Kim, Jong-Gyu;Yang, Seung-Ho;Kim, Hui-Tae;Kang, Dong-Hyuk;Kim, Hong-Jip;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.5
    • /
    • pp.78-84
    • /
    • 2007
  • In the regeneratively cooled combustion chambers of liquid rocket engine using hydrocarbon fuels, coking occurs as the wall temperature increases which results in compounds deposition on the wall of cooling channels. This phenomenon reduces cooling capability of the coolant which finally causes damage to the combustor by overheating of the chamber wall. In this paper, experiment results using an electrical heating equipment to simulate the regeneratively cooled channel are introduced and based on the results the compatibility of copper alloy with hydrocarbon fuel Jet A-1 is investigated.

Numerical Analysis of Forced and Mixed Convection around the Circular Cylinder for Compressible Flow (압축성 유동장에서의 원형 실린더 주위의 강제 및 혼합대류에 대한 수치 해석)

  • 최윤호;이현찬;유재석;김기현
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.126-139
    • /
    • 1995
  • 저속의 압축성 유동장에서의 원형 실린더 주위의 유동 및 열전달특성을 해석하였다. 비압축성 유동장에서의 실린더 주위의 유동 및 열전달현상에 대하여는 실험과 수치해석을 포함한 광범위한 연구가 진행되어 왔으며 매우 잘 알려져 있다. 실린더 벽면과 주위 유동장의 온도차가 큰 경우, 밀도의 변화가 커지므로 유동장은 압축성 유체가 되나 지배 방정식의 복잡함과 적절한 수치해석 방법의 부족으로 실린더 주위의 유동장을 압축성유체로 해석한 경우는 매우 드물다. 현재 압축성유동 해석에 널리 사용되는 time marching algorithm은 저속의 유동장 해석시 지배방정식에 나타나는 eigenvalue들의 괴리에 의하여 수렴속도가 현저히 떨어지게 된다. 본 연구에서는 이와 같은 난점을 극복할 수 있는 time-derivative preconditioning 방법을 사용하여 온도차가 큰 유동장에서의 강제 및 혼합대류에 대한 계산을 수행하였고 이들의 열전달특성을 비교하였다. 강제대류의 경우 실린더 벽면 온도의 증가에 따른 밀도 감소의 영향은 유동장의 Re수를 감소시켜 확산의 영향을 증가시키면서, 혼합대류의 경우 부력의 영향은 가열되는 유동장의 범위와 재순환 영역을 강제대류에 비해 현저히 감소시킨다.

  • PDF

Numerical Analysis of Heat Transfer in the Ribbed Channel Inserted with Tape (테이퍼가 설치된 리브(rib)이 있는 채널의 열전달에 대한 수치해석)

  • Kang, Ho-Keun;Ahn, Soo-Whan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.638-644
    • /
    • 2010
  • Numerical predictions of a fully developed turbulent flow through a square duct ($30mm{\times}30mm$) with twisted tape inserts and with twisted tape plus interrupted ribs are respectively conducted to investigate regionally averaged heat transfer and flow patterns. A rib height-to-channel hydraulic diameter(e/$D_h$) of 0.067 and a lengthto-hydraulic diameter(L/$D_h$) of 30 are considered at Reynolds number ranging 8,900 to 29,000. The interrupted ribs are axially arranged on the bottom wall. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 28 mm, length of 900 mm, and 2.5 turns. Each wall of the square channel is composed of isolated aluminum sections. Two heating conditions are investigated for test channels with twisted tape inserts and rib turbulators: (1) electric heat uniformly applied to four side walls of the square duct, and (2) electric heat uniformly applied to two opposite walls of the square channel. The results show that uneven surface heating enhances the heat transfer coefficient over uniform heating conditions, and significant improvements can be achieved with twisted tape inserts plus interrupted ribs.

Application of Open-source OpenFOAM for Simulating Combustion and Heating Performance in Horizontal CGL Furnace (수평형 CGL 소둔로의 연소 및 가열 성능 해석을 위한 오픈소스 OpenFOAM 기반 전산유체 해석)

  • Kim, GunHong;Oh, Kyung-Teak;Kang, Deok-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.553-561
    • /
    • 2017
  • The main motivation for this study was to establish a CFD-based procedure for the analysis of heating characteristics, particularly in industrial furnaces. As certain open-source software packages have gained popularity in dealing with complex industrial problems, the OpenFOAM framework was selected for further development of advanced physical models to meet industrial requirements. In this study, the newly developed comprehensive model was applied to simulate physical processes in the full-scale horizontal furnace of a continuous galvanizing line (CGL). The numerical results obtained indicate that the current approach predicts heating characteristics reasonably well. It was also found that radiative heat transfer plays a dominant role in heating the moving strip. To improve the predictability of our method, further work is required to model the turbulence-chemistry interaction realistically, as well as to impose a physically correct thermal wall boundary condition.

Improvement of Drying Performance of Natural Convection Drier Part I : Analysis of Natural Convection Drier (자연대류형 건조기의성능향상을 위한 모형실험 I. 자연대류형 건조기의 분석)

  • 류관희;정도섭;정창주
    • Journal of Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.25-31
    • /
    • 1979
  • 본연구는 건조에 필요한 열과 공기를 열원으로부터의 자연대류만에 의존하는 간역화력건조기의 성능향상을 도모하기 위하여 실시되었으며 옥수수를 대상으로 모형실험을 통하여 분석한 결과는 다음과 같이 요약된다. 1. 건조기 화구의 공기열입구의 크기는 송풍량에 영향을 미치며 공기의 유입속도가 16m/min 이하가 되도록 충분히 만들어야 한다. 2. 곡물층을 통과하는 송풍량은 곡물층의 두께가 클수록 증가하며 송풍량과 곡물층 두께와의 관계는다음식으로 나타났다. $q=CD^{-k}$ 3. 송풍량은 실험범위내에서는 열원으로부터 곡물층의 높이와 가열공기의 온도상승에 따라 각각 직선적으로 증가하였다. 4. 송풍량은 곡물층의 두께, 열원으로부터의 곡물의 높이 및 가열공기의 온도상승에 의하여 옥수수층의 경우 다음과 같이 추정될 수 있다. $ q=0.00265H(\Delta T) D^{-0.76}$ 5. 바람이 송풍량에 미치는 영향은 매우 커서 8km/hr의 풍속을 가진 바람이 유입구측으로부터 볼 때 송풍량은 바람이 없을 때보다 무려 5배나 증가하였다. 6. 건조실의 전후방간의 가열공기의 온도차이는 열원으로부터 곡물층의 높이가 낮을수록 증가하였으며 이 현상은 바람이 불 때 더욱 현저하게 나타났다. 7. 건조기의 벽면을 통한 열손실은 열원으로부터 곡물층의 높이와 가열공기의 온도상승에 따라 각각 직선적으로 증가하였다.

  • PDF