• Title/Summary/Keyword: 가연

Search Result 480, Processing Time 0.02 seconds

A Study on the transition of Explosion to Eire of LPG and Its' Prevention (LP가스 폭발 후 화재 전이 현상 및 전이 방지에 관한 연구)

  • 오규형;이성은
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.20-26
    • /
    • 2004
  • The purpose of this study is to investigate the transition mechanism and prevention mechanism of gas explosion to fire. Transition phenomena of explosion to fire of LPG in the explosion vessel of its size of TEX>$100 cm {\times} 60 cm {\times} 45 cm$ was visualized using the high speed video camera and the mechanism was analysed from the videograph. Newspaper size of $30cm {\times} 20cm$ was used for combustible sample in this experiments and LPG-air mixture was ignited by 10 ㎸ electric spark. Experimental parameter was gas concentration, size of vent area and position of combustible solid. Size of vent area were varied as $10cm {\times} 9cm, 13cm {\times} 10cm, 27cm {\times} 20cm, 40cm {\times} 27cm$, and the position of combustible was varied in 4 point. Carbon dioxide was used to study the prevention mechanism of explosion to fire transition of LPG. Based on this experiment we can find that transition possibility of explosion to fire on solid combustible from explosion is depends on concentration of LPG-air mixture and the exposure time of solid combustibles in high temperature atmosphere of flame and burnt gas. And cooling or inerting of the atmosphere after explosion can be prevent the transition of explosion to fire on solid combustibles from gas explosion.

An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection (샌드위치패널 벽면보호용 스프링클러설비 적용 실험)

  • Seo, Dong-Hun;Kim, Won-Hyung;Kim, Jong-Hoon;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.37-43
    • /
    • 2017
  • Domestic sandwich panel buildings are widely used on walls and roofs of factories and warehouse facilities. Factory and warehouse facilities have high fire load and rapid spread of fire due to their use characteristics, leading to large fires. Due to the characteristics of materials, walls and roofs are collapsed, resulting in life damage and property damage. In this regard, this study examined domestic and international standards of sprinkler facilities to prevent ignition of sandwich panel walls. Also, in order to check whether the fire was prevented by installing the head on the wall of the sandwich panel, the fire test was carried out with 10 cm, 60 cm, and 120 cm from the wall along the sprinkler head installation standard of domestic fire safety standards. As a result of the fire test, it was confirmed that the sandwich panel was prevented from igniting when the head of water pressure 0.1 MPa and water quantity K-80 was installed. According to the separation distance, it was impossible to measure the temperature at 10 cm, but at 60 cm, At the maximum temperature of $525^{\circ}C$ and 120 cm, the maximum temperature of the wall of the sandwich panel was measured as $276^{\circ}C$. As a result of the fire test, considering the fire point of 450 degrees Celsius in the fire test of the sandwich panel, the distance from the sandwich panel wall to the combustible is more than 120 cm.

Proposal for Ignition Source and Flammable Material Safety Management through 3D Modeling of Hazardous Area: Focus on Indoor Mixing Processes (폭발위험장소 구분도의 3D Modeling을 통한 점화원 및 가연물 안전관리 방안 제안: 실내 혼합공정을 중심으로)

  • Hak-Jae Kim;Duk-Han Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purpose: This study aims to propose measures for the prevention of fire and explosion accidents within manufacturing facilities by improving the existing classification criteria for hazardous locations based on the leakage patterns of flammable liquids. The objective is to suggest ways to safely manage ignition sources and combustible materials. Method: The hazardous locations were calculated using "KS C IEC 60079-10-1," and the calculated explosion hazard distances were visualized in 3D. Additionally, the formula for the atmospheric dispersion of flammable vapors, as outlined in "P-91-2023," was utilized to calculate the dispersion rates within the hazardous locations represented in 3D. Result: Visualization of hazardous locations in 3D enabled the identification of blind spots in the floor plan, facilitating immediate recognition of ignition sources within these areas. Furthermore, when calculating the time taken for the Lower Explosive Limit (LEL) to reach within the volumetric space of the hazardous locations represented in 3D, it was found that the risk level did not correspond identically with the explosion hazard distances. Conclusion: Considering the atmospheric dispersion of flammable liquids, it was concluded that safety management should be conducted. Therefore, a method for calculating the concentration values requiring detection and alert based on realistically achievable ventilation rates within the facility is proposed.

가정용 소형 단상변압기 안전성 실태 분석

  • Kim, Seong-Sam
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.188-189
    • /
    • 2013
  • 본 논문에서는 산업현장과 교육시설에서의 가정용 소형 단상변압기의 규격품 사용 여부와 운영상의 안전성 실태를 분석하였다. 전기용품 안전 관리법에 따른 법정인증을 받지 않은 제품이 5개 조사되었으며, 단자 체결형 변압기의 경우 전원선 접속 불량(헐거움), 설치 및 고정 불량, 접지 미체결(누락), 전압조정 핸들 파손, 변압기 상부 가연물 방치가 주요 불합리 항목으로 조사되었다.

  • PDF

전기화재(IV) -가연물 취급장소에서 고려하여야 할 정전기 대책-

  • 원종수
    • Fire Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.47-57
    • /
    • 1988
  • 정전기에 의한 사고가 발생하려면, 정전기의 발생, 착화 능력을 가진 위험한 방전의 발생, 폭발성 가스, 증기가 공기와의 비율에서 폭발 한계 내에 존재할 것 등의 세가지 조건이 필요하다. 따라서 정전기에 의한 착화, 폭발 사고를 방지하기 위해서는 항상 이 세가지 관점에서 검토하여, 어떤 조건 하에서도 3개 조건 중 적어도 하나 이상을 제거하는 것이 필요하다. 이하, 정전기에 의한 재해 중에서 그 방전이 착화원이 되어서 발생하는 가연성 가스 등의 폭발, 화재에 의한 재해의 방지 대책에 한정해서 개설한다.

  • PDF

실내가연물의 화재 성상에 관한 연구

  • Kim, Hong;Ham, Sang-Geun
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.109-112
    • /
    • 2000
  • 화재는 여러 가지 요인들에 의해 복합적으로 작용하는 현상이다. 특히 건물화재는 다분히 3차원적이고 무수히 많은 변수들에 의해 그 피해 규모가 급속히 커져가고 있는 추세에 있다. 건물화재는 각 국가의 고유한 사회 문화적 수준과 환경에 따라 큰 차이가 있으므로 선진국의 연구결과를 그대로 국내의 상황에 적용하는 데는 다소 무리가 있다 따라서 좀 더 많은 실험을 통한 우리의 환경에 좀 더 가까운 실험 데이터 및 결과가 필요하다(중략)

  • PDF

하수슬러지 재이용을 위한 성상 조사

  • An, Byeong-Ho;Park, Heung-Jae;Kim, Bu-Gil
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.507-509
    • /
    • 2008
  • 유입수 성상이 서로 다른 9개소의 하수처리장에서 발생하는 하수슬러지의 재이용 가능성에 대하여 퇴비 기준 및 부숙토 기준으로 검토하였다. (1) 공장폐수가 유입되는 하수처리장의 탈수케이크에 함유된 Cr, Cu, Pb성분은 퇴비 및 부숙토 기준치를 초과하였다. (2) 중금속의 함량에 관한 기준을 만족하는 탈수케이크는 가연분 함량이 낮으므로 직접적인 재이용은 어려울 것으로 생각된다.

  • PDF

A Study of Drone Forensics using BusyBox based on Linux (리눅스 기반 BusyBox를 사용하는 드론 포렌식 연구)

  • Ryu, Ga-Yeon;Hong, Deukjo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.273-275
    • /
    • 2017
  • 드론 기술이 발전하여 다양한 용도로 활용 가능해지면서 사용 범위와 시장을 더욱 넓혀가고 있다. 또한 사물인터넷(IoT) 시대에 포렌식 적용 대상의 범위가 스마트 워치, 스마트 TV 등 우리 생활에 다양하게 자리잡은 임베디드 시스템으로 확대되고 있다. 본 논문에서는 리눅스 포렌식 아티팩트 분석 기법을 이용하여 Busybox를 사용하는 드론에 대해 중요 데이터 증거를 수집하는 방법을 제시한다.

The Study on the Physical Properties of DTY Produced by Pin and Belt False Twist Texturing Systems (Pin과 Belt type 가연 System으로 제조된 DTY의 물성에 관한 연구)

  • 전계현;김승진
    • Textile Coloration and Finishing
    • /
    • v.12 no.2
    • /
    • pp.79-88
    • /
    • 2000
  • Draw textured yarns have many differences with yarn quality as well as wearing, due to the bulkiness, thermal and physical properties according to the false twist texturing system. In order to improve such property, many studies have been accomplished for developing good textured yarns and their fabrics, but these have been essentially obtained by experimental data or mathematical analysis. This study surveyed various properties of DTY produced by false twist texturing system, namely pin and crossed-belt false twist insertion systems. And 6 yarn specimens of 2 group(pin twisting type, belt twisting type) were measured and analysed.

  • PDF

가연성 가스의 누출에 따른 확산현상 연구

  • 오규형;이성은;김종복
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.180-185
    • /
    • 2000
  • 연료로 사용하는 가연성 가스의 양이 증가함에 따라 가스 사고 건수도 증가하고 있으며 가스사고 중 약 35% 정도가 가스의 누설사고였다. 이러한 가스의 누설사고는 일정시간 경과 후 적절하게 배출되지 못할 경우 화재나 폭발사고로 이어질 위험성이 매우 크다. 즉 가스의 누출은 폭발이나 연소의 3요소 중에서 가연물이 제공되는 과정으로 가스폭발사고나 화재를 예방하기 위해서는 근본적으로 가스의 누출을 방지해야 한다. (중략)

  • PDF