• Title/Summary/Keyword: 가연성 한도

Search Result 45, Processing Time 0.019 seconds

A Study of Consequence Analysis of Physical Explosion Damage in CO2 Storage Tank (CO2 임시 저장 탱크에서의 물리적 폭발에 따른 피해영향 고찰)

  • Seo, Doo-Hyoun;Jang, Kap-Man;Lee, Jin-Han;Rhie, Kwang-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.12-19
    • /
    • 2015
  • $CO_2$ is non-flammable, non-toxic gas and not cause of chemical explosion. However, various impurities and some oxides can be included in the captured $CO_2$ inevitably. While the $CO_2$ gas was temporarily stored, the pressure in a storage tank would be reached above 100bar. Therefore, the tank could occur a physical explosion due to the corrosion of vessel or uncertainty. Evaluating the intensity of explosion can be calculated by the TNT equivalent method generally used. To describe the physical explosion, it is assumed that the capacity of a $CO_2$ temporary container is about 100 tons. In this work, physical explosion damage in a $CO_2$ storage tank is estimated by using the Hopkinson's scaling law and the injury effect of human body caused by the explosion is assessed by the probit model.

A Study on the Combustion Characteristics of Organic Insulation Materials According to the Gas Toxicity Evaluation Method (가스유해성 평가방법에 따른 유기단열재의 연소특성에 관한 연구)

  • Shim, Ji-Hun;Lee, Jae-Geol;Han, Kyoung-Ho;Kim, Ju-Wan;Song, Seok-Hun;Jo, Hyung-Won;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.519-524
    • /
    • 2022
  • Domestic building finishing materials are being evaluated according to KS F 2271 standards according to the notification of the Ministry of Land, Infrastructure and Transport, and this test is evaluated using laboratory animals. In this study, experiments were conducted on highly combustible organic insulation materials such as EPS, urethane, and phenolic foam. The purpose of this study was to analyze the cause of the behavioral suspension of the experimental mice by measuring the average behavioral suspension time of the mice caused by the harmful gas generated when these three types of insulation materials were burned. FTIR analysis and smoke density experiment were performed as a cause analysis method for the behavioral suspension of mice, and the experimental results were analyzed by dividing the causes of behavioral suspension into suffocation by particulate matter and toxic inhalation by gaseous substances. As a result of the test, urethane was evaluated as the most harmful insulation material, and as a result of FTIR analysis and smoke density test as a cause analysis for the gas toxicity test results, it is judged that the behavioral stop of the rats by suffocation is higher than the effect of toxic inhalation. This study is a basic study on the cause analysis of harmful gases, and it will be necessary to prepare the toxicity basis and analyze various materials and gases.

Fire Retardant Treatment to the Plywood with Di-ammonium Phosphate [(NH4)2 HPO4](I) -Hot and Cold Soaking Treatment and Redrying of Treated Plywood by Hot Platen- (제2인산(第二燐酸) 암모늄에 의한 합판(合板)의 내화처리(耐火處理)(I) -온냉침지처리(温冷浸漬處理)와 열판(熱板)에 의한 처리합판(處理合板)의 재건조(再乾燥) -)

  • Lee, Phil Woo;Chung, Woo Yang
    • Journal of Korean Society of Forest Science
    • /
    • v.60 no.1
    • /
    • pp.30-36
    • /
    • 1983
  • Plywood, the representative interior decorative or structural material, is so inflammable that it may cause big fires. Therefore, it is required inevitably to manufacture the "Fire retardant treated plywood", and it will be a study on the redrying of treated plywood that we ought to solve. This study was carried out to investigate the absorption of 20% $(NH_4)_2HPO_4$ solution into the soaked plywoods by hot/cold soaking for 3/3, 6/3, 9/3 and 12/3 hours and to study drying process with drying curves and drying rates by press-drying at the platen temperature of 130, 145, 160 and $175^{\circ}C$. Solution absorption of plywoods in hot/cold soaking method increased steadily with the prolonged soaking time, and water absorption is higher than DAP absorption, and then chemical retention (DAP) exceeded the minimum retention [$1.125kg/(30cm)^3$] even in the shortest soaking treatment. Drying curves of water-soaked plywoods inclined more steeply than those of DAP soaked plywoods. And the drying proceeded rapidly with the increase in platen temperature and terminated in 2.5-4 minutes at the temperature of 160 and $170^{\circ}C$. Drying rate also increased generally with the increase of platen temperature. So it was at $175^{\circ}C$ in DAP-soaking and at $160^{\circ}C$ in water-soaking when the drying rate became above 10%/min.

  • PDF

Study on the Waste Treatment Status and Characteristics in the Small Villages (농촌마을의 생활폐기물 처리실태 및 발생특성 연구)

  • Lee, Hyeong-Jin;Choi, Hun-Geun;Kim, Sung-Bum;Cho, Mun-Sik;Kim, Seong-Mi;Park, Soo-Jeong;Chung, Il-Rok;Oh, Gil-Jong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.112-130
    • /
    • 2006
  • In order to improve the waste management system for the unit of small villages, we visited 14 counties nationwide and investigated the present conditions of the farming and fishing villages on waste management. First, we selected one concentrated residential type village and one separated residential type village. Then we investigated the quantities and the characteristics of the domestic wastes generated from the 2 sample villages that we chose early on. The concentration of 7 heavy metals in open burned residuals was analyzed. The results are as follows: (1) We distributed the 799 questionnaires to public servants (83 Gun, 716 Myon) and 337 questionnaires to residents. In accordance with a result of questionnaire on the Volume-Based Waste Fee System, the rate of participated questionnaire was 70.3% from public servants and 31.8% from residents. (2) From the survey on two chosen villages, the generation of municipal waste was 48.6g/person/day in A Village, 54.3g/person/day in B Village. This amount was smaller than that of national average of 1.05kg because of excluding recyclable wastes and some of incinerated combustible waste. (3) The 14 counties entered the aged society. There were 2 aging societies, 8 aged societies and 4 super-aged societies. And the average ratios of Public financial independence and waste budget of financial independence were 16.1% and 17.9% respectively. These are lower than that of national average of 57.2% and 31.4%. This indicates that these factors seemed to be operated with the hindrance insettling Volume-Based Waste Fee System in the small villages.

  • PDF

Studies on Press Drying of Fire-Retardant Treated Plywood (내화처리합판(耐火處理合板)의 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Kim, Jong Man
    • Journal of Korean Society of Forest Science
    • /
    • v.56 no.1
    • /
    • pp.1-25
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable and can cause fire accidents. causing destruction of human life and property. To diminish the fire disaster, fire retardant plywood is indeed required. In the methods of manufacturing the fire retardant plywood, a soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions redrying of soaked plywood is of the utmost importance. In this study 3.5mm and 5.0mm thickness plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid minalith, and water solution, 1-, 3-, 6-, and 9 hour-soaking treatments in borax-boric acid and minalith, and 6- and 9 hours in the other chemicals were applied and after the treatment hot drying was applied to treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$ of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1) In the 9 hours-soaking treatment of fire retardants by hot and cold bath method, the chemical retentions of 3.5mm thickness plywood could be attained within the range ($1.125-2.25kg/(30cm)^3$) of minimum retention specification as follows: $1.353kg/(30cm)^3$ in monoammonium phosphate, $1.331kg/(30cm)^3$ in diammonium phosphate, $1.263kg/(30cm)^3$ in ammonium sulfate, $1.226kg/(30cm)^3$ in borax-boric acid. But the chemical retention, $0.906kg/(30cm)^3$, in minalith could not be attained within the range of minimum retention specification. And also in case of 5.0mm thickness plywood, chemical retentions, as $1.356kg/(30cm)^3$ and $1.166kg/(30cm)^3$ respectively, of ammonium sulfate and diammonium phosphate could be attained within the range minimum retention specification, but the other fire retardant chemicals could not. 2) In the 6- and - hours-soaking treatments of 3.5mm and 5.0mm thickness plywood, the drying curve sloped of chemical treated plywood was smaller than that of water treated. The drying rate related to thickness of treated plywood, was about three times as fast in 3.5mm thickness plywood compared with 5.0mm thickness plywood. 3) In the treatment at $120^{\circ}C$ of hot platen temperature, the drying rates of chemical-treated plywood showed the highest quantity in diammonium phosphate of 3.5mm and 5.0mm thickness plywood. But the drying rate of water treated plywood was highest during the 6- and 9 hours-soaking treatments. 4) The drying rate remarkably increased with proportion to increase of the platen temperature, and the values were respectively 1.23%/min., 6.54%/min., 25.75%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 3.5mm thickness plywood and 0.55%.min., 2.49%/min., 8.19%/min. in hot platen temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in 5.0mm thickness plywood. 5) In the fire retardant degree of chemical treated plywood, the loss in weight was the smallest in diammonium phosphate, next was in monoammonium phosphate and ammonium sulfate, and the greatest was in borax-boric acid and minalith. And the fire-retardant effect in burning time, flame-exhausted time and carbonized area were greatest in diammouniun phosphate, next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric acid and minalith.

  • PDF