• Title/Summary/Keyword: 가압 시스템

Search Result 313, Processing Time 0.029 seconds

Convergence Study on Organic Sludge Treatment System (유기성 슬러지 처리 시스템에 관한 융합연구)

  • Han, Doo-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.213-217
    • /
    • 2020
  • An eco-friendly water purifier was developed using natural minerals, plants, and sludge from water purification plants. A wastewater complex treatment system using this water purification agent was developed. The wastewater complex treatment system goes through the process of inflow of contaminated water, input of water purification agent, operation of a pressurized flotation device, sludge flotation, sludge collection and treatment water discharge. This device was applied to the removal of green algae in livestock desorption liquid, broiler washing water, factory wastewater, sewage treatment plant and pond to obtain excellent removal rate. The use of natural water purification agents for organic waste purification has not been investigated.

PTA-I test of KSR-III Propulsion Feeding System (KSR-III 추진기관 공급계 PTA-I 종합수류시험)

  • 권오성;정영석;조인현;정태규;오승협
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.3
    • /
    • pp.22-29
    • /
    • 2003
  • The propulsion feeding system of KSR-III is composed of tubes, valves and PSC, and controls the flow of propellant entering to engine. The test of PTA-I is carried out to verify the characteristic of propulsion feeding system and component. The tests of operation characteristic of component, hydraulic characteristic of tubes, flow control using venturi, oscillation of dynamic pressure, characteristic of regulator are carried out. Troubles of component are found out, and renewed, and the performance of the propulsion feeding system is verified through PTA-I. The results of PTA-I are used to the configuration of propulsion feeding system and test of PTA-II.

Study on the Safety Analysis on the Cooling Performance of Hybrid SIT under the Station Blackout Accident (발전소 정전사고 시 Hybrid SIT의 냉각성능 평가를 위한 안전해석에 관한 연구)

  • Ryu, Sung Uk;Kim, Jae Min;Kim, Myoung Joon;Jeon, Woo Jin;Park, Hyun-Sik;Yi, Sung-Jae
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.64-70
    • /
    • 2017
  • The concept of Hybrid Safety Injection Tank (Hybrid SIT) proposed by the Korea Atomic Energy Research Institute (KAERI) has been introduced for the purpose of application to the Advanced Power Reactor Plus (APR+). In this study, the SBO situation of the APR+ was analyzed by using the MARS-KS code in order to evaluate whether the operation of the Hybrid SIT has an effect on the cooling performance of the Reactor Coolant System (RCS). According to the analysis, when the actuation valve on the pressure balancing line (PBL) is opened, the Hybrid SIT's pressure rises rapidly, forming equilibrium with the RCS pressure; subsequently, a flow is injected from the Hybrid SIT into the reactor vessel through the direct vessel injection (DVI) line. The analysis showed that it is possible to keep the core temperature below melting temperature during the operation of a Hybrid SIT.

The Hybrid Rocket Internal Ballistics with Two-phase Fluid Modeling for Self-pressurizing $N_2O$ I (자발가압 성질을 가진 아산화질소의 2상유체 모델링을 통한 하이브리드 로켓 내탄도 해석 I)

  • Lee, Jung-Pyo;Rhee, Sun-Jae;Woo, Kyoung-Jin;Oh, Ji-Sung;Jung, Sik-Hang;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.45-49
    • /
    • 2011
  • The blow-down oxidizer feed system with self-pressurizing $N_2O$ has more advantages than the regulated system. However, it is difficult to predict the exhaust flow rate because there exist two phases in the $N_2O$ tank - liquid phase and gas phase, and the properties of $N_2O$ in storage tank are varied continuously during blow-down. In this paper, a method that can analyse simply the blow-down oxidizer feed system is studied. The properties of saturated $N_2O$ are found from the NIST data base, and mass flow through the orifice is modeled as NHNE. Cold flow test with hybrid rocket combustor is performed for the comparison where the results should found from the good agreement.

  • PDF

A Study on Numerical Technique of the Hardened Grout Formed by Grouting (약액주입 시 형성된 고결체의 수치해석 기법 연구)

  • Lee, Jong-Hwi;Chun, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.6
    • /
    • pp.27-37
    • /
    • 2011
  • Recently, pressure grouting is widely being used in construction site for strength improvement of ground and water proof, reinforcement and so on. It is necessarily required to estimate an appropriate injection pressure and injection time for economical and reasonable construction in the site through the size and shape of the hardened grout measured according to ground condition. However, sampling for the hardened grout is time-consuming and needs high cost on preliminary test in the site. The system which could predict the size and shape of the hardened grout does not exist until now. Thus, numerical method based on VOF method and porous model was used for the calibration chamber injection test with injection pressure (50 kPa, 100 kPa, 150 kPa) in this study. The results indicate that the numerical technique based on VOF method and porous model among CFD analysis is expected to be a basic study for the prediction of the behavior and solidification of pressure grouting.

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Characteristics of Air Flow in the Vestibule with Multiple Fire Doors in an Apartment Building (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 공동주택 부속실내에 다수 출입문의 존재시 기류특성)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.30-36
    • /
    • 2014
  • The pressurized smoke control system in the vestibule is important for fire safety in buildings because it is concerned with egress time of people and the safety of fire fighters. The vestibule pressurization system can prevent smoke from entering the vestibule using differential pressure when fire doors are closed and using the egress velocity when fire doors are open. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule in order to assure the uniform air egress velocity through a fire door when it is open. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where multiple doors are installed and it was found that the reverse flow occurs when the damper position in vestibule is not appropriate.

Structural Analysis of Satellite Propulsion System Module Bracket (인공위성 추진시스템 모듈 브라켓의 구조해석)

  • Lee, Gyun Ho;Kim, Jeong Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.89-95
    • /
    • 2003
  • Propulsion system of the current developing satellite is roughly composed of propellant tank and four major modules. Each module prevides the pulse momentum for spacecraft attitude control, filling/draining of propellant and pressurant, propellant filtering, and the change of flow passage in the spacecraft emergency situation, respectively. These modules will be fixed on the propulsion platform with their suitable mounting brackers, so the brackets shall be designed sufficiently to support a function of the modules under launch environment and on-orbit condition. The purpose of this article is to check if all the bracket designs satisfy the defined structural requirements through finite element analysis, and then to verify structural safety.

Development of a Safety Assessment System on Aging Management in Existing CANDU Steam Generators (가압중수로 증기발생기의 경년열화 관리를 위한 안전성 평가 시스템 개발)

  • Shin, So Eun;Lee, Jeong Hun;Park, Tong Kyu;Jung, Jong Yeob
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Since steam generator (SG) tubes are located in the boundary between the primary and secondary systems of nuclear power plant (NPP), the SG is one of the most important components in the aspects of the safety of NPP. The magnetite ($Fe_30_4$) deposition, so-called fouling, is generally known as a major aging mechanism of CANDU SGs, and this aging mechanism makes the heat transfer efficiency between the primary and secondary systems of NPP reduced. Therefore, the development of SG safety assessment system which can evaluate the effect of the SG aging degradation mechanism should be needed for safety of NPP. In this study, through the suggestion of the guideline for SG safety assessment, it is possible to strengthen the basic of establishing the effective SG aging management technique. The SG safety assessment is carried out by CATHENA(Canadian Algorithm for THErmalhydraulic Network Analysis). It is possible to determine the integrity of SGs by identifying the main safety parameters which can be changed by the aging degradation of CANDU SGs.

Field Study for Location Estimation System of Dielectric breakdown in Gas Insulated Switchgear (GIS 절연파괴 위치 추정 시스템의 현장 적용 연구)

  • Min, Byoung-Woon;Lee, Jung-Bok;Kim, Jung Pyo;Kim, Jung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.543-544
    • /
    • 2015
  • GIS(Gas Insulated Switchgear:가스절연 개폐장치)는 절연성능이 뛰어난 $SF_6$가스로 절연되어 초고압 전력의 제어(차단,투입)를 담당하는 중요한 장치이다. GIS는 절연성능을 검증하기 위하여 현장 운전전에 공장검수시험(내전압시험)과 현장 가압 시험을 수행한다. 이 때 GIS의 조립/운반/설치의 오류로 인한 절연성능 저하로 절연파괴(내부아크)가 발생될 수 있다. 그러나 GIS는 $SF_6$가스로 밀폐되어 있어 절연파괴를 정확히 알 수 없을 뿐만 아니라 사고 위치를 확인하기 어렵다는 단점을 가지고 있다. 따라서 본 논문에서는 이런 문제를 해결하기 위하여 GIS 내부에서 발생되는 사고를 신속하게 탐지하고 위치를 정확하게 표정할 수 있도록 개발된 GIS 절연파괴 위치 추정 시스템의 현장 적용연구를 수행하였다. 이를 통해 GIS 절연파괴 위치 추정 시스템의 성능을 확인하였다.

  • PDF

Study on the Remote Control Power Management System of an Unmanned Stations (무인사업장의 원격제어 전원관리시스템 고찰)

  • Kim, Kwang-Soo;Lee, Gyeong-Bae;Choi, Jang-Geon;Lee, Kyung-Woo;Byun, Doo-Gyoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1317-1318
    • /
    • 2015
  • 최근 ICT 기술의 발전으로 원거리에 위치한 광역 상수도의 취수장, 가압장, 감압변실 및 배수지 등의 시설물은 중앙제어실에서 효율적인 설비운영을 위해 원격통합관리로 감시제어를 수행하여 생산성을 제고하고 있다. 단위사업장에 낙뢰 유입으로 인한 순간정전이나 오동작 등의 영향에 의한 누전차단기 트립 증상이나 제어계측설비의 시스템 다운현상이 발생할 경우에 전원설비나 계측제어설비를 복구하기 위해서는 운영자가 사업장 현장에 출동하여 설비를 복구해야만 한다. 출동에 따른 많은 시간과 비용이 발생할 뿐만 아니라 응급조치가 미흡할 경우에는 수돗물 공급 중단 등의 위험성이 발생할 소지가 있다. 본 논문에서는 단위사업장의 서지유입이나 설비 오동작 등의 원인으로 무인사업장 설비에 System down 현상이 발생하면 단위사업장에 출동하지 않고 원격의 중앙제어실에서 원격 명령 또는 자동 프로그램에 의한 전원 Reset 동작으로 현장 제어설비가 원활하게 동작함으로써 무인사업장의 효율적인 운영관리가 가능한 원격제어 전원관리시스템 구축사례를 제시하고자 한다.

  • PDF