• Title/Summary/Keyword: 가스 소화설비

Search Result 74, Processing Time 0.024 seconds

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Results of the Precision Monitoring (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(II): 도시가스 및 수송용 - 정밀모니터링 결과 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.57-66
    • /
    • 2019
  • This study carried out on-site investigation and precision monitoring to prepare proper design and operation technical guidelines for the use of bio gas in organic waste resources (fertilizing urine, food waste, food waste, food waste, etc.). According to the government's mid- and long-term policy on bio gasification, the expansion of waste resources is actively being pushed forward. However, facilities that use the biogas produced for urban gas and transportation are still under-efficient. Precision monitoring was carried out for biogasification facilities of organic waste resources in seven locations nationwide. When the results of precision monitoring were summarized with the four-season average, the efficiency analysis of each organic waste resource showed that the organic breakdown rate was 66.3% on average on VS basis. Analysis of biogas characteristics before and after pretreatment revealed that the $H_2S$ average of the entire facility was measured at 949.7 ppm using iron salts and desulfurization (dry, wet) and that the quality refining facility shearing and rear end was 29.0 ppm and 0.3 ppm. The methane content was found to be reduced by 65.6% at the rear of the fire tank, 63.5% at the back and 97.5% at the rear.

Numerical Analysis on Development of Nozzle Shape for NOVEC Gas Extinguishing System (NOVEC가스 소화설비용 노즐 형상 설계에 대한 수치해석)

  • Yun, Jeong In;Jung, Kyung Kuk;Kim, Ji Sung;Kim, Sung Yoon;Rho, Beom-Seok;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.7
    • /
    • pp.939-944
    • /
    • 2018
  • Clean fire extinguishing agents refer to chemical that can replace Halon 1211 and Halon 1310 according to the Montreal Protocol fermented to protect the Earth's ozone layer. In Korea and abroad, system standardization and performance evaluation of clean fire extinguishing agents are being carried out. This paper proposes an optimal nozzle shape by modeling and numerical analysis of various nozzle shapes based on general clean fire extinguishing system. The ejection speed of the nozzle can be improved by studying three - dimensional modeling of the nozzle for two shapes, Type A and B. Flow analysis was performed on the two types of nozzles and the gas velocity and pressure distribution were measured with different nozzle diameters. It was confirmed that the jetting speed was changed at the nozzle outlet according to the number and diameter of the nozzle holes. The flow rate increased with increasing the pressure regardless of the nozzle hole diameter. Based on the results obtained from the experiment, the K-factor value was deduced. Finally, a nozzle with a 12-hole structure with a 5-mm nozzle hole was proposed.

Study on Energy Independence Plan for Sewage Treatment Plant (하수처리시설의 에너지 자립화 방안 연구)

  • Kim, Young-Jun;Lee, Jong-Yeon;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.49-55
    • /
    • 2010
  • The objectives of this study are to analyze the energy independence plan and to propose a suitable sewage treatment plant in Korea. The total amount of electricity consumption for public sewage treatment plant was estimated as 1,812 GWh in 2007. It was estimated that total 16 sewage treatment plants with renewable energy systems produced electricity of 15 GWh per year, which could replace 0.8% of total electricity used for sewage treatment. It was found that domestic sewage treatment plants with power generation plants by digestion gas were installed in 7 places and produced electricity of 13 GWh per year. It was also found that the power generation plants by digestion gas were the most cost-effective for sewage treatment plant out of the renewable energy systems based on the benefit-cost analysis.

Life Cycle Analysis of Greenhouse Gas Emissions of By-Product Hydrogen Produced from Coke Oven Gas in Steel Mill (제철소 코크스 오븐 가스 부생수소 전과정 온실가스 배출량 분석)

  • YEIM LEE;WOOJAE SHIN;YEJIN YU;HANHO SONG
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.636-642
    • /
    • 2022
  • The "Hydrogen Economic Activation Road map" was announced in 2019, and hydrogen demand is expected to exceed 470,000 tons per year in 2022 and keep increasing. Under this circumstance, it has become important to understand the greenhouse gas (GHG) emissions associated with various hydrogen production pathways. In this study, the evaluation of life cycle GHG emissions regarding the hydrogen produced as by-product from coke oven gas (COG) in steel mill is conducted. To cover the possible range of operations, three literatures were reviewed and their data of inputs and outputs for the process were adopted for calculation. Life cycle inventories and emission factors were mostly referred to GaBi and Intergovernmental Panel on Climate Change (IPCC) guidelines, respectively. When there are multiple products from a single process, the energy allocation method was applied. Based on these sources and the assumptions, the life cycle emission values of COG-based hydrogen were found to be 3.8 to 4.7 kg/CO2-eq./kg-H2.

The Seismic Design of Water Extinguishing Piping Systems for Equivalent Static Analysis Method (등가정적해석법에 의한 수계 파이프 시스템의 내진설계)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.100-105
    • /
    • 2012
  • In this study, seismic design in pipeline of pressurized water supply system of water extinguishing system has been carried out. This study described a generation of artificial earthquake wave compatible with seismic design spectrum, and also determined equivalent static loads to analyzed the response spectra acceleration by the simulated earthquake motion. This study constructed powerful engineering base for seismic design, and presented equivalent static analysis method for seismic design of water and gas extinguishing piping system. Also, this study readied basis that can apply seismic design and performance estimation of fire fighting system as well as pipeline of water extinguishing system from result of this research. Hereafter, if additional research by earthquake magnitude and ground kind is approached, reliance elevation, safety raising and performance based design of fire fighting system see to achieve.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Results of the Precision Monitoring (바이오가스 이용 기술지침 마련을 위한 연구(II) - 정밀모니터링 결과 중심으로)

  • Moon, HeeSung;Bae, Jisu;Park, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.1
    • /
    • pp.65-78
    • /
    • 2018
  • According to the in social aspects such as population growth, urbanization and industrialization, development of livestock industry by meat consumption, amount of organic wastes (containing sewage sludge and food waste, animal manure, etc) has been increased annually in South Korea. Precise monitoring of 11 organic wastes biogas facilities were conducted. The organic decomposition rate of organic wastewater was 68.2 % for food wastes, 66.8 % for animal manure and 46.2 % for sewage sludge and 58.8 % for total organic wastes. As a result of analyzing the biogas characteristics before and after the pretreatment, the total average of the whole facility was measured to be 560 ppm using iron salts and desulfurization, and decreased to 40 ppm when the reduction efficiency was above 90 %. Particularly, when iron salt is injected into the digester, the treatment efficiency is about 93 %, and the average is reduced to 150 ppm. In the case of dehumidification, the absolute humidity and the relative humidity were analyzed. The dew point temperature of the facility where the dehumidification facility was well maintained as $14^{\circ}C$, the absolute humidity was $12.6g/m^3$, and the relative humidity was 35 %. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure) through precision monitoring.

Photo-crosslinking of PLA Fabrics by UV Irradiation (자외선 조사에 의한 PLA 직물의 광가교)

  • Yun, Deuk-Won;Jang, Jin-Ho
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.51-51
    • /
    • 2011
  • PLA(Poly(lactic acid))는 옥수수, 사탕수수와 같은 천연재료에서 얻어진 젖산(lactic acid or lactide)을 원료로 하여 합성한 생분해성 고분자로서 석유자원의 고갈과 환경오염에 대한 관심이 고조됨에 따라 합성고분자를 대체할 재료로 각광받고 있다. 일반적인 PLA의 장점으로 투명성, 굽힘강성, 방수성, 가열밀봉성 등이 있으며, 단점으로는 열안정성, 내구성, 충격 강도 등이 있다. PLA를 섬유로 사용될 경우 농림 토목용 생분해성 소재 뿐 아니라 실크의 광택과 뛰어난 드레이프성, 감촉을 갖는 장점이 있다. 또한 수분을 신속하게 흡수하여 발산시키는 특성을 가지고 있고, 낮은 연소열과 가스량, 자기 소화성 등의 방염 특성 등을 지녀 의류 인테리어 소재로 매력적인 특성을 가지고 있다. PLA는 바이오고분자 중 비교적 높은 용융온도를 가지고 있지만 특히 염색 및 가공조건 등 고온 처리에 의해 기계적 강도가 저하되는 단점이 있어 내열성 및 기계적 강도의 향상이 필수적이다. 내열성 및 기계적 강도 향상을 위한 가장 손쉬운 방법은 고분자 사슬을 가교시키는 것으로서 열처리 또는 감마선, 전자선, 자외선 조사를 이용할 수 있는데 열에 의한 가교는 균일한 열전달과 고온이 필요하며 감마선 및 전자선 조사는 설비의 고비용과 방사성 노출 위험으로 인해 비친환경적이다. 따라서 다루기 쉽고 비용이 적게 들고 친환경적인 장점을 가진 자외선 조사법을 이용한 PLA의 광가교의 연구가 필요하다. 본 연구의 목적은 PLA 직물의 열안정성과 기계적 특성을 향상시키기 위해 광개시제와 자외선 조사를 이용하여 PLA 직물의 광가교를 수행하였다.

  • PDF

A Study on the Improvement of Sludge Digestion Efficiency by Solubilization Equipment and Gas Purification System (가용화장치 및 가스정제 설비에 의한 슬러지 소화 효율 향상에 관한 연구)

  • Jang, Seong-Ho;Yi, Pyong-In;Lee, Yong-Dea;Kim, Han-Soo;Cho, Han-Jin;Ryu, Jae-Young;Kim, Sang-Woo
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.853-859
    • /
    • 2014
  • The purpose of this study was to improve low digestibility in anaerobic digestion facility of the sewage treatment plant. To perform this research, sludge digestion and digestion gas purification facilities in sewage treatment plant was applied. In the result of this study, it was very effective for sludge reduction from the improvement of digestive efficiency. In addition, it was confirmed that high purity $CH_4$ (methane) was produced. This results can be useful as basic data to improve the low digestibility in anaerobic digestion processes.

Implementation of Smart Fire Safety System (스마트 화재 안전 시스템의 구현)

  • Duk-Kyu Choi;Yun-Ho Kang;Min-Sung Jang;Ju-An Son;Hee-Jun Seo;Hyeon-Gyu Lee;Jin-Ho Kim
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.01a
    • /
    • pp.279-280
    • /
    • 2023
  • 소방청 국정감사에서 2020년 전국 자동화재속보설비 화재신고 32,764건 가운데 32,685건이 오작동으로 출동해 소방서 출동의 99.8%가 헛걸음이었다. 그리고 화재가 발생할 경우 화재경보장치와 대피경로를 안내하는 비상등이 미흡하고, 화재 연기가 제거되지 않아 대피가 힘들어질 뿐만 아니라 미처 대피 못한 인원을 파악하는 등의 신속한 대처가 힘들다. 본 논문은 화재 상황에서 피해를 최소화하기 위한 '스마트 화재 안전 시스템' 기술을 제안한다. 화재가 발생할 경우, 대피 경로를 안내하는 유도등 작동 및 경보음과 LED의 작동으로 화재발생을 경고하여 신속한 대처를 할 수 있게 도와주고, 문과 창문의 자동 개방 및 환기팬 작동으로 인한 유해가스를 환기시켜 준다. 그리고 스프링클러 작동과 소화제를 자동 분사하여 화재의 번짐 등 2차 피해를 예방하여 준다. 또한, 자동 신고 기능으로 더욱 빠르게 화재를 진압할 수 있게 도와주기 때문에 피해를 최소화할 것이다.

  • PDF

Process gas purification using cyclone recirculation and cooling process (싸이클론 재순환, 냉각공정을 이용한 공정가스 정제 연구)

  • Kim, Ju-Hoe;Jo, Woo-Jin;Choi, Young-Tae;Jo, Young-Min;Kim, Sang-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2018
  • Renewable energy has been of interests in the area of modern alternative fuels. Biogas is produced in waste landfill sites through anaerobic digestion processes, including hydrolysis, acidogenesis, organic acid fermentation (acetogenesis), and methane fermentation (methanogenesis). High contents of fine dust and moisture limited its utilization for direct combustion, town gas and vehicle fuel. Thus, this study proposed a new design for a cooling device using a centrifugal cyclone for simultaneous removal of fine dust and moisture as a pretreatment in the purification processes. A heat exchanger and an ID fan, which are installed inside and outside of the cyclone, in order to cool the humid gas below the freezing point and form a foggy mist. Such an atmosphere enhanced to capture fine dust as recirculating the cold mist flow. The water removal rate was 80.8% at a relative humidity of 95%, and the particle removal efficiency was 98.3% for $2.5{\mu}m$. Simultaneous removal efficiency was 70.8% and 99.6% for particle and moisture respectively.