• Title/Summary/Keyword: 가스포화 경우

Search Result 70, Processing Time 0.031 seconds

Clinical Experience of Long-term Home Oxygen Therapy (재택산소요법을 받고 있는 환자들에 대한 임상 관찰)

  • Lee, Young-Suk;Cha, Seung-Ick;Han, Chun-Duk;Kim, Chang-Ho;Kim, Yeun-Jae;Park, Jae-Yong;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.283-291
    • /
    • 1993
  • Background: Long-term low flow oxygen therapy not only increases survival, but also improves the quality of life in patients with chronic obstructive pulmonary disease (COPD) with chronic hypoxemia. For the assessment and improvement of the status of home oxygen therapy, we analyzed clinical experience of 26 patients who have been administered low flow oxygen at home. Method: Twenty-six patients (18 men and 8 women) who have been received long-term oxygen therapy (LTOT) at home were examined. We reviewed physical characteristics, clinical history, pulmonary function test, ECG, arterial blood gas analysis, hemoglobin and hematocrit, types of oxygen devices, inhalation time per day, concentration of administered $O_2$, duration of $O_2$ therapy, and problems in the home oxygen therapy. Results: The underlying diseases of patients were COPD 14 cases, far advanced old pulmonary tuberculosis 9 cases, bronchiectasis 2 cases, and idiopathic pulmonary fibrosis 1 case. The reasons for LTOT at home were noted for cor pulmonale 21 cases, for dyspnea on exertion and severe ventilatory impairment 4 cases, and for oxygen desaturation during sleep 1 case. The mean values of aterial blood gas analysis before home oxygen therapy were $PaO_2$ 57.7 mmHg, $PaCO_2$ 48.2 mmHg, and $SaO_2$ 87.7%. And the mean values of each parameters in the pulmonary function test were VC 2.05 L, $FEV_1$ 0.92 L, and $FEV_1$/FVC% 51.9%. Nineteen patients have used oxygen tanks as oxygen devices, 1 patient oxygen concentrator, 2 patients oxygen tank and liquid oxygen, and other 4 patients oxygen tank together with portable oxygen. The duration of oxygen therapy was below 1 year in 3 cases, 1~2 years in 15 cases, 3~5 years in 6 cases, 9 years in 1 case, and 10 years in 1 case. All patients have inhalated oxygen with flow rate less than 2.5 L/min. And only 10 patients have inhalated oxygen more than 15 hours per day, but most of them short time per day. Conclusion: For the effective oxygen administration, it is necessary that education for long-term low flow oxygen therapy to patients, their family and neighbor should be done, and also the institutional backup for getting convenient oxygen devices is required.

  • PDF

Magnetic Properties of NixFe100-x(x=40~50) Permalloy Powders and Dust Cores Prepared by Gas-Atomization (가스 분무법으로 제조된 NixFe100-x(x=40~50) 퍼멀로이 분말 및 압분 코아의 자기적 특성)

  • Noh, T.H.;Kim, G.H.;Choi, G.B.;Kim, K.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.6
    • /
    • pp.218-223
    • /
    • 2002
  • We investigated the magnetic properties of High Flux-type $Ni_{x}Fe_{100-x}$(x=40∼50, wt.%) permalloy powders and dust cores. The powder was prepared by conventional gas atomization in mass production scale. At the composition of $Ni_{x}Fe_{55}$, saturation magnetization was maximum. In case of lower Ni content than X=45, the $M_{s}$, decreased largely with the decrease in Ni content, which is due to the invar effect. The permeability of compressed powder cores increased with the decrease in Ni content, which was considered to be due to the decrease in the magnetostriction. In addition, the dust core with Ni=45% showed the lowest core loss because of the increase in electrical resistivity leading to the low eddy current loss. From the better frequency dependence of permeability, larger Q value and superior DC bias characteristics of Ni=45% than those of Ni=50% core, it was confirmed that the 45%Ni-55%Fe powder alloy was better material for the dust core than commercial High Flux core materials.

A Study on the Factors Affecting the Influence Ranges of Ammonia Leakage by Using KORA Program (KORA 프로그램을 활용한 암모니아 누출사고 영향범위 결정 기여요인 연구)

  • Lim, Hyeongjun;Kwak, Sollim;Jung, Jinhee;Ryu, Taekwon;Choi, Woosoo;Lee, Jieun;Lee, Jinseon;Lee, Yeonhee;Kim, Jungkon;Yoon, Junheon;Ryu, Jisung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.38-44
    • /
    • 2018
  • Ammonia is used primarily as a refrigerant in refrigeration facility and SCR of a plant, and is frequently involved in leakage accidents. This study was conducted by selecting ammonia, a material with a wide influence range when evaluated, as a material with higher vapor pressure and lighter than air. In this study, the influence ranges were computed using KORA(Korea Off-site Risk Assessment supporting tool) with four different environmental factors : ground roughness, sealing, operating temperature, pressure, and leakage hole size. As a result, the difference in the influence range of ground roughness is approximately 4.62 times, while the ammonia storage tank shows a difference in the reduction rate of 0.64 when sealed. The extent of impact increased with increasing leakage depending on storage temperature and pressure, and when storing higher than the saturation vapor pressure, the impact range showed an average growth rate of 3.45 % per 0.1 Mpa($45^{\circ}C$). The influence ranges based on the size of the leakage holes is shown to be proportional to the area of the leakage zone.

Seismic attenuation from VSP data in methane hydrate-bearing sediments (메탄 하이드레이트 부존 퇴적층으로부터 획득한 수직탄성파 (VSP) 자료에서의 탄성파 진폭 감쇠)

  • Matsushima, Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • Recent seismic surveys have shown that the presence of methane hydrate (MH) in sediments has significant influence on seismic attenuation. I have used vertical seismic profile (VSP) data from a Nankai Trough exploratory well, offshore Tokai in central Japan, to estimate compressional attenuation in MH-bearing sediments at seismic frequencies of 30-110 Hz. The use of two different measurement methods (spectral ratio and centroid frequency shift methods) provides an opportunity to validate the attenuation measurements. The sensitivity of attenuation analyses to different depth intervals, borehole irregularities, and different frequency ranges was also examined to validate the stability of attenuation estimation. I found no significant compressional attenuation in MH-bearing sediments at seismic frequencies. Macroscopically, the peaks of highest attenuation in the seismic frequency range correspond to low-saturation gas zones. In contrast, high compressional attenuation zones in the sonic frequency range (10-20 kHz) are associated with the presence of methane hydrates at the same well locations. Thus, this study demonstrated the frequency-dependence of attenuation in MH-bearing sediments; MH-bearing sediments cause attenuation in the sonic frequency range rather than the seismic frequency range As a possible reason why seismic frequencies in the 30-110 Hz range were not affected in MH-bearing sediments, I point out the effect of thin layering of MH-bearing zones.

Adsorption and Desorption Dynamics of Ethane and Ethylene in Displacement Desorption Process using Faujasite Zeolite (제올라이트(faujasite)를 이용한 치환탈착공정에서 에탄, 에틸렌의 흡, 탈착 동특성)

  • Lee, Ji-In;Park, Jong-Ho;Beum, Hee-Tae;Yi, Kwang-Bok;Ko, Chang-Hyun;Park, Sung Youl;Lee, Yong-taek;Kim, Jong-Nam
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.768-775
    • /
    • 2010
  • Adsorption dynamics of ethane/ethylene mixture gas and desorption dynamics during the displacement desorption with propane as a desorbent in the column filled with faujasite adsorbent were investigated experimentally and theoretically. The simulation that adopted heat and mass balance and an ideal adsorbed solution theory (IAST) for the multicomponent adsorption equilibrium well predicted the experimental breakthrough curves of the adsorption and desorption. At the adsorption breakthrough experiments, roll-ups of ethane increased as the adsorption pressure increased and the adsorption temperature decreased. During the displacement desorption with propane in the column saturated with ethane/ethylene mixture gas, almost 100% of ethylene was obtained for a certain time interval. The adsorption strength of the desorbent greatly affected the adsorption and re-adsorption dynamics of ethylene. The re-adsorption capacity for ethylene has been greatly reduced when iso-propane, which is stronger desorbent than propane, was used as desorbent. It was found from the simulation that the performance of the displacement desorption process would be superior when the ratio of ${(q_s{\times}b)}_{C_2H_4}/{(q_s{\times}b)}_{C_3H_s}$ was 0.83, that is, the adsorption strengths of ethylene and the desorbent were similar.

Magnetic Properties of RF Diode Sputtered FeN Multilayer Films (RF Diode 스퍼터 방법으로 증착된 FeN 다층 박막의 자기적 특성)

  • 최연봉;박세익;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.42-47
    • /
    • 1995
  • FeN thin films for inductive recording heads were sputter deposited using RF diode sputtering mehtod from a pure iron target onto 7059 glass substrates, and their magnetic properties were measured. The magnetic properties were greatly affected by film thickness, gas pressure, sputter power and flow ratio of $N_{2}$ to Ar. Single layer FeN films with their thickness varied from $1,000\;{\AA}$ to $6,000\;{\AA}$ were doposited. 800 W sputter power, 3 mT gas pressure, $N_{2}$ to Ar flow ratio of 6.6 : 100 were the sputtering conditions. Up to 7 layers of FeN films having total thickness of $6,000\;{\AA}$ were deposited using $SiO_{2}$ of $30\;{\AA}$ thickness as intermediate layers and their coercivity and saturation magnetization were measured. The sputtering conditions were the same as those in the single layer films. Easy axis coercivity of the single layer FeN films gradually decreased as their thickness was increased, but for the films with their thicknesses above $3,000\;{\AA}$, the coercivity changed very little. As the number of the FeN layers were increased, the coercivity decreased We estimated the grain size of FeN films from the FWHM (Full Width at Half Maximum) of X-ray diffraction peaks. The grain size steadily decreased from about $200\;{\AA}$ to $120\;{\AA}$ as the number of layers were increased. Minimum hard axis coercivity of 0.4 Oe was obtained when the number of layers was four. Maximum relative permeability was 2,900 when the number of layers was three. The cut off frequeocy of the multilayer films were above 100 MHz.

  • PDF

The Usefulness of Noninvasive Positive Pressure Ventilation in Patients With Acute Respiratory Failure after Extubation (기관내 관 제거 후 발생한 급성 호흡부전에서 비침습적 양압 환기법의 유용성)

  • Na, Joo-Ock;Lim, Chae-Man;Shim, Tae-Sun;Park, Joo-Hun;Lee, Ki-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.350-362
    • /
    • 1999
  • Background: Acute Respiratory failure which is developed after extubation in the weaning process from mechanical ventilation is an important cause of weaning failure. Once it was developed, endotracheal reintubation has been done for respiratory support. Noninvasive Positive Pressure Ventilation (NIPPV) has been used in the management of acute or chronic respiratory failure, as an alternative to endotracheal intubation, using via nasal or facial mask. In this study, we evaluated the usefulness of NIPPV as an alternative method of reintubation in patients who developed acute respiratory failure after extubation. Method: We retrospectively analyzed thirty one patients(eighteen males and thirteen females, mean ages $63\pm13.2$ years) who were developed acute respiratory failure within forty eight hours after extubation, or were extubated unintentionally at medical intensive care unit(MICU) of Asan Medical Center. NIPPV was applied to the patients. Ventilatory mode of NIPPV, level of ventilatory support and inspiratory oxygen concentration were adjusted according to the patient condition and results of blood gas analysis by the attending doctors at MICU. NIPPV was completely weaned when the patients maintained stable clinical condition under 8 $cmH_2O$ of pressure support level. Weaning success was defined as maintenance of stable spontaneous breathing more than forty eight hours after discontinuation of NIPPV. Respiratory rate, heart rate, arterial blood gas analysis, level of pressure support, and level of PEEP were monitored just before extubation, at thirty minutes, six hours, twenty four hours after initiation of NIPPV. They were also measured at just before weaning from NIPPV in success group, and just before reintubation in failure group. Results: NIPPV was successfully applied to thirty-one patients of thirty-two trials and one patient could not tolerated NIPPV longer than thirty minutes. Endotracheal reintubation was successfully obviated in fourteen patients (45%) among them. There was no difference in age, sex, APACHE III score on admission at MICU, duration of intubation, interval from extubation to initiation of NIPPV, baseline heart rate, respiratory rate, arterial blood gas, and $PaO_2/FiO_2$ between the success and the failure group. Heart rate and respiration rate were significantly decreased with increase $SaO_2$ after thirty minutes of NIPPV in both groups(p<0.05). However, in the patients of failure group, heart rate and respiratory rate were increased again with decrease in $SaO_2$ leading to endotracheal reintubation. The success rate of NIPPV treatment was significantly higher in the patients with COPD compared to other diseases(62% vs 39%) (p=0.007). The causes of failure were deterioration of arterial blood gas without aggravation of underlying disease(n=9), aggravation of undelying disease(n=5), mask intolerance(n=2), and retained airway secretion(n=l). Conclusion: NIPPV would be a useful therapeutic alternative which can avoid reintubation in patient who developed acute respiratory failure after extubation.

  • PDF

Application of Earthworm Casting-derived Biofilter Media for Hydrogen Sulfide Removal (지렁이 분변토를 이용한 생물담체가 충전된 바이오필터에 의한 황화수소 제거)

  • Yoo, Sun-Kyoung;Lee, Eun-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.820-825
    • /
    • 2007
  • Earthworm casting was the natural fertilizer that contained high concentrations of nutrients such as nitrogen, phosphate and potassium and of over $10^8$ CFU/ml of microorganisms. Greater than 80% of feed was excreted through the fermentation by the intestinal enzyme, after worm had eaten feeds such as fallen leaves and rotten roots under the ground. Also, the soil structure of casting was known to be very efficient in the aspects of the porosity, the water permeability, and deodorizing activities. In this research, the biofilter packed with a biomedia made of casting and waste polyurethane foam, a binder, which helped to improve the durability and perpetuity of casting, was investigated to degrade malodorous hydrogen sulfide gas. The biomedia had no need of extra supply of nutrients and of microbial inoculations. On the beginning of the operations, it showed 100% removal of hydrogen sulfide gas without lag phase. At SV of 50 $h^{-1}$, hydrogen sulfide gas from the outlet of the biofilter was not detected, when inlet concentration increased to 450 ppmv. After that, removal efficiency decreased as increasing inlet hydrogen sulfide concentration. Hydrogen sulfide removal was maintained at almost 93% until inlet concentration was increased up to 950 ppmv, at which the elimination capacity of $H_2S$ was 61.2 g $S{\cdot}m^{-3}{\cdot}h^{-1}$. Maximum elimination capacity guaranteing 90% removal was 61.2, 65.9, 84.7, 89.4 g $S{\cdot}m^{-3}{\cdot}h^{-1}$ at SV ranging from 50 $h^{-1}$ to 300 $h^{-1}$, but was 59.3 g $S{\cdot}m^{-3}{\cdot}h^{-1}$ at SV of 400 $h^{-1}$. The results calculated from Michaelis-Menten equation revealed that $V_m$ increased from 66.04, 88.96, 117.35, 224.15, to 227.54 g $S{\cdot}m^{-3}{\cdot}h^{-1}$ with increasing space velocity in the range of 50 $h^{-1}$ to 400 $h^{-1}$. However, saturation constant$(K_s)$ decreased from 79.97 ppmv to 64.95 and 65.37 ppmv, and then increased to 127.72 and 157.43 ppmv.

THE EFFECTIVENESS OF TWO SEDATIVE REGIMEN USED FOR CHILD PATIENT WHO FAILED TO ORAL CHLORAL HYDRATE (Chloral hydrate 경구 진정에 실패한 소아환자를 대상으로 사용한 두 가지 진정요법의 효과)

  • Lee, Sang-Min;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.505-516
    • /
    • 2000
  • Chloral hydrate is one of the most widely used sedative agents to control the difficult-to-treat young age group in the dental clinic. We are often frustrated to see the patient still awake and cry with agitation even after far more than the normal onset time of Chloral hydrate. In such a case, the patient has to be rescheduled for another sedation visit with different agents and/or routes which greatly disappoints the guardians. This study was designed to test the efficacy of one sedative regimen that can possibly help the clinician complete scheduled treatment without postponement. We have tried sleep induction with mixed gas of Enflurane(2vol%) and $N_2O(50%)-O_2(50%)$ for $60\sim120$ seconds to 35 patients of those who failed to respond properly to the dose(70mg/kg)of oral Chloral hydrate. The Result of this regimen was compare to those of two oral regimen of Chloral hydrate/Hydroxyzine and Chloral hydrate only Analyses of result on vital signs and behavior pattern were performed. The outcome of the study suggest that sleep induction by a short inhalation of low dose of $Enflurane/N_2O-O_2$ provide dentist with suitable condition for the completion of scheduled treatment in the patient who failed to oral Chloral hydrate. Evidence of adverse effect was not detected or reported during and/or after the procedures.

  • PDF

퇴적 마그네슘의 승온속도와 열분해특성

  • Han, U-Seop;Lee, Su-Hui
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.116-116
    • /
    • 2013
  • 마그네슘은 스마트폰, 전자기기 케이스, 내화벽돌과 아크용접봉 제조시의 첨가물 등으로 사용되고 있는데, 최근에는 재활용을 위한 마그네슘 용해로를 취급하거나 가공하는 사업장이 증가하고 있어 사고위험성이 높아지고 있다. 금속분을 취급하는 사업장에서의 금속분진은 저장이나 축적 등과 같이 주로 퇴적물로서 존재한다. 퇴적분진의 발화온도는 퇴적물 형상과 두께, 입경, 분위기 가스의 유속, 산소농도, 부유분진의 농도, 퇴적밀도, 수분 등의 많은 영향인자가 관여하기 때문에 이론적 예측이 힘들고 실험적인 측정에 의존할 수 밖에 없는 것이 현실이다. 본 연구에서는 연소성이 높고 화재폭발사고사례가 많은 마그네슘(Mg) 분진을 사용하여 승온속도 변화에 따른 열분해특성을 조사하였다. 퇴적분진의 열적특성을 조사하기 위하여 METTLER TOLEDO의 TGA/DSC1를 사용하였으며, Mg 시료의 평균입경은 38, $142{\mu}m$이다. 입경 $38{\mu}m$의 Mg 시료의 열중량분석 결과, 중량증가는 $400{\sim}500^{\circ}C$의 범위에서 시작되며 $550^{\circ}C$에서 급격하게 중량이 증가하고 있으며, 증량증가개시온도(Temperature of weight gain)는 $460^{\circ}C$에서 시작하여 $900{\sim}950^{\circ}C$ 범위에서 중량 증가 포화값에 도달하였다. 입경 $142{\mu}m$의 Mg에 대하여 공기중 승온속도를 5, 10, $20^{\circ}C/min$으로 변화시키면서 실온에서 $900^{\circ}C$까지 가열 시키는 경우의 시료의 중량 변화에 따른 열분해 특성은 승온속도가 증가할수록 2단계의 S자 곡선은 완만하게 상승을 나타내며 중량증가개시온도가 높아지는 경향을 보이고 있다. 중량증가개시온도가 승온속도에 따라 변화하는 결과를 나타내고는 있지만, 시료량의 증가에 따른 영향을 열중량분석 실험방법의 제약으로 인하여 확인할 수 가 없었다. 그러나 만일 시료량이 크게 증가하는 경우에는 동일한 승온조건에서 중량증가 개시온도는 낮아질 가능성이 있다. 중량증가는 시료의 산화반응에 의한 것이므로 시료량의 증가는 시료 내부에의 열의 축적을 용이하게 하여 보다 낮은 온도에서도 산화반응이 충분히 일어나는 조건이 형성되기 때문이다. 승온속도가 증가할수록 산화 반응한 괴상형태의 연소입자가 크게 증가하고 있는 것을 알 수 있다. 승온속도에 따른 중량개시온도 곡선을 보면 [그림 24]와 같으며 승온속도 5, 10, $20^{\circ}C/min$의 증가에 따라 중량개시온도는 각각 490, 510, $530^{\circ}C$가 얻어졌으며 승온속도의 증가에 따라 중량개시온도가 증가하는 경향을 보이고 있다.

  • PDF