A LPG Dispensing Control System based on a 16-bit Microprocessor (16-bit 마이크로프로세서로 구현한 LPG 충전 제어 시스템)

  • 이상훈;홍남관
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2002
  • In this paper, a POS interfacing and temperature compensable LPG dispensing control system(LDCS) has been developed. A LDCS includes a 16-bit 80C196 microprocessor, RAM, ROM, video driver, and programmable peripheral devices. Based on gas flow encoding pulse, temperature-voltage conversion values and apparatus calibration values, the LDCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with a 10-bit A/D conversion and its range is from +7$0^{\circ}C$ to -3$0^{\circ}C$ with a 0.5$^{\circ}C$ resolution.

  • PDF

Influence of particle size on sensing characteristics of hydrothermally treated nano-sized $SnO_2$ (수열합성법으로 제조한 나노 크기의 $SnO_2$ 입자 크기에 따른 반응 특성)

  • ;Anh-Hoa Bui
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.134-134
    • /
    • 2003
  • SnO$_2$를 모물질로 하는 가스센서는 n형 산화물 반도체로서 공기중의 산소의 흡탈착 및 전자의 수수에 의해 전기전도도의 변화로 특정 가스를 감지한다. 지금까지 반도체식 가스센서의 모물질로 가장 많이 연구되어 왔지만 아직도 선택성, 안정성 등 여러 가지 문제를 안고 있다. 그리고 개선방안으로 귀금속 촉매의 첨가 및 입자의 크기의 조절 등이 흔히 연구되어 왔다. 따라서 본 연구에서는 순수한 SnO$_2$ 를 이용하여 소결 온도 및 입자 크기에 의한 영향을 CO가스 및 수분에 대한 감도, 반응 시간을 통해 알아보았다. 수열 합성 및 침전 법으로 나노 크기의 SnO$_2$ 분말을 합성하여 스크린 인쇄법으로 후막 가스센서를 제조하였다 침전법에서 SnCl$_4$에 암모니아수로 pH=10.5로 적정하여 SnO$_2$ 분말을 얻었다. 그리고 입자 크기를 조절하기 위해 수열 합성 시 autoclave 내의 수열처리 온도를 100, 150, 20$0^{\circ}C$로 조절하여 SnO$_2$ 분말을 제조하고 입자 크기와 성분분석을 위해 XRD, SEM, TEM, BET 측정을 하였다. 그 결과 침전법으로 제조한 입자의 크기는 20nm 정도였으며 수열 처리한 SnO$_2$ 입자는 10nm이하의 미세한 입자를 얻을 수 있었다. 수열 합성 시 온도가 높아질수록 더 작은 입자 크기를 얻을 수 있었고 600, 7()0, 80$0^{\circ}C$ 열처리 후 입자성장이 침전법에 의한 SnO$_2$ 분말보다 더 작게 일어났다. 이렇게 제조한 나노크기의 SnO$_2$ 분말을 이용하여 습도 및 CO 가스에 대한 그 특실을 평가하였다. CO 20ppm에 대하여 40%정도의 감도를 보였으며 입자가 작아질수록 높은 감도를 보이는 것을 확인 할 수 있었다. 반면 CO 가스와 반응 후 회복 시 입자 의기가 작아질수록 회복이 늦어짐을 알 수 있었다. 그리고 15$0^{\circ}C$에서 습도에 대한 반응 후 회복시간을 조사해보니 같은 결과를 얻을 수 있었다. 이것은 입자 필기가 작아질수록 많은 흡착 사이트를 제공함으로써 높은 감도를 가지지만 반면 다량의 흡착된 가스들이 탈착 하는데 더 많은 시간이 소요되었기 때문이다.

  • PDF

Performance Change of Gas Turbine with a Evaporation Cooling System in Summer Season (하절기 기화냉각장치 설치에 따른 가스터빈 성능변화)

  • Chung, Hyeon-Jo;Yoo, HoSeon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2017
  • This study analyzed the change of gas turbine performance with air temperature decrease by the evaporation cooling system in summer season. Gas turbine performance was tested on the condition that ambient temperature is $29{\pm}1^{\circ}C$. As a result, Air temperature at the compressor inlet was decreased by $4.12^{\circ}C$ after the installation of evaporation cooling system. Decreased air temperature followed by increased air density affected gas turbine performance, Which increased compressor pressure ratio by 0.27, improved compressor efficiency of 0.29 %p, improved gas turbine enthalpy drop efficiency of 0.31 %p, improved the gas turbine efficiency by 0.44 %p, improved electric power output by 4,489 kW. On the other side, the influence of the humidity increase and flow resistance increase was negligible.

  • PDF

Analysis of the Control Variables for Natural Gas Liquefied Process Using Mixed Refrigerant (혼합냉매를 이용한 천연가스 액화공정의 제어변수 분석)

  • Lee, Jae Yong;Kim, Mun-Hyun;Park, Chan-Cook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.51-57
    • /
    • 2013
  • The process of liquefied natural gas is less then $-160^{\circ}C$ to natural gas by cooling at atmospheric pressure. When control strategy was made, one of the most significant is analysis of process. It is important to understand the control variable change according to manipulated variable change. In this study, we experiment natural gas liquefied process using C3MR(Propane Pre-cooled Mixed Refrigerant) process by BSU(Bench Scale Unit). We analyzed the change of refrigerant temperature and natural gas temperature according to the change of refrigerant flow rate so as to search an influence flow rate according to adjust each manipulated variables. One of the manipulated variable affected a number of control variables, but were able to confirm a control variable with a large response.

The Estimation of Temperature distribution around Gas Storage Cavern (저온가스 저장공동 주위암반의 온도분포 예측에 관한 연구)

  • Lee, Yang;Lee, Seung-Do;Moon, Hyun-Koo
    • Tunnel and Underground Space
    • /
    • v.14 no.1
    • /
    • pp.16-25
    • /
    • 2004
  • As underground caverns have many advantages such as safety and operation, they can also be used for gas storage purpose. When liquefied gas is stored underground, the cryogenic temperature of the gas affects the stability of the storage cavern. In order to store the liquefied gas successfully, it is essential to estimate the exact temperature distribution of the rock mass around the caverns. The main purpose of this study is the development of theoretical solution to be able to estimate the temperature distribution around storage caverns and the assessment of the solution. In this study, a theoretical solution and a conceptual model for estimating two and three dimensional temperature distribution around the storage caverns are suggested. Based on the multi-dimensional transient heat transfer theory, the theoretical solution is successfully derived by assuming the caverns shape as simplified geometry. In order to assess the theoretical solution, by performing numerical experiments with this multi-dimensional model, the temperature distribution of the theoretical solution is compared with that of numerical analysis. Furthermore, the effects of the caverns size are investigated.

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

Thermodynamic Analysis on Hybrid Turbo Expander - Heat Pump System for Natural Gas Pressure Regulation (히트펌프를 적용한 터보팽창기 천연가스 정압기지의 열역학적 분석)

  • Sung, Taehong;Kim, Kyoung Hoon;Han, Sangjo;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.13-20
    • /
    • 2014
  • In natural gas distribution system, gas pressure is regulated correspond to requirement using throttle valve which is releasing huge pressure energy as useless form. The waste pressure can be recovered by using turbo machinery devices such as a turbo expander. In this process, excessive temperature drop occurs due to Joule-Thompson effect during the expansion process. Installing natural gas boiler before or after the turbo expander prevents temperature drop. Fuel cell or gas engine hybrid system further improve the efficiency, but 1~2% of total transporting natural gas is used for operating the hybrid system. In this study, a heat pump system is proposed as a preheating device which can be operated without using transporting natural gas. Thermodynamic analysis on evaporating and condensing temperatures and refrigerants is conducted. Results show that R717 is proper refrigerant for the hybrid system with high COP and low turbine work within the defined operating conditions. In domestic usage in Korea, the heat pump system has more economic feasibility owing to natural gas being imported with a high price of LNG form.

A Study on the Pyrolysis Processing for sludge disposal in sewage treatment plant (하수처리장내 슬러지 처리를 위한 열분해공정에 관한 연구)

  • Ha, Sang-An;Kim, Hyeoog-Seok;Sung, Nak-Chang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.4
    • /
    • pp.65-74
    • /
    • 2002
  • This Study was investigated operating condition of pyrolysis processing for sludge disposal in sewage treatment plant. Important parameters studied include running time of pyrolysis, run time of dry and pyrolysis processing, water content of sewage sludge, solids amount of sewage sludge(TS%), condition of pyrolysis temperature. Most degradation reaction of sewage sludge are first order, it assumed first order and elucidated the kinetics. This was the basis of characteristics analysis of sludge degradation mechanism. Also, with the increasing of temperature, how the yield of oil and char product change was observed, and the distribution of gas product components was observed. Main components of gas and carbon product are a little difference with pyrolysis temperature, but it consist of $CH_4$, $C_2H_4$, $C_3H_8$, $C_4H_{10}$, toluene, $C_6H_6$, $SO_2$, CO etc. The gas of $C_1-C_4$ yield increased along with degradation temperature of $670^{\circ}C$ and oil yield decreased of $C_6H_6$ and $C_6H_5OH$ with temperature of $600^{\circ}C$. Particularly, low value added char yield 134kg/t at $670^{\circ}C$, but increased to 194kg/t at pyrolysis temperature of $600^{\circ}C$. In the result of elementary analysis on it, it is mainly composed of carbon. From this fact, in pyrolysis of sludge, it comfirmed that carbonization reaction occur at high temperature well.

  • PDF

Microstructure and Magnetic Characteristics of Yttrium Iron Garnet Thin Films Prepared by RF Magnetron Sputter (고주파 마그네트론 스퍼터법에 의해 제조된 Yttrium Iron Garnet 박막의 미세구조 및 자기적 특성)

  • 박명범;김병진;조남희
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.3
    • /
    • pp.293-300
    • /
    • 1999
  • 고주파 마그네트론 스퍼터법을 이용한 YIG(yttrium iron garnet)박막 제조시 기판유형, 기판온도, 스퍼터전력, 스퍼터가스 등의 증착변수와 증착후 열처리 조건이 YIG 박막의 결정성, 화학조성, 미세구조 그리고 자기적 특성에 미치는 영향에 대하여 고찰하였다. 75$0^{\circ}C$ 이상의 온도에서 수행한 증착후 열처리에 의하여 비정질 박막이 결정화되었으며, 특히 GGG(gadolinium gallium garnet)기판 위에 제조된 박막은 강한 (111)우선배향성을 나타냈다. 박막조성은 스퍼터가스 내의 산소분율에 민감하게 영향을 받았으며, 산소분율이 20%인 스퍼터가스를 사용하여 제조된 박막은 Y2.88Fe3.84O12의 조성을 나타내었다. 증착후 열처리 온도가 90$0^{\circ}C$로부터 110$0^{\circ}C$로 증가함에 따라, GGG 기판위의 박막의 표면거칠기는 2.5nm에서 40nm로 증가하였으며, 보자력과 강자성 공명 선폭은 감소하였다.

  • PDF

A Study on the Supply Gas Temperature Characteristics of Silent Discharge Type Ozonizer by Applying Radio Frequency Voltage (고주파 전압인가에 의한 무성방전형 오존발생기의 원료가스 온도특성에 관한 연구)

  • 이상근;전병준;박용권;박원주;이광식;권혁한;송현직;박중협
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.46-54
    • /
    • 2001
  • In this paper, a co-axial cylinder type ozonizer using silent discharge applying radio frequency voltage known as an ozone generation was designed and fabricated. A cooling system was installed to investigate the characteristics of ozone generation in accordance with temperature change of the supplied gas known as an important factor. The characteristics of ozone generation were investigated in accordance with the change of cooling temperature.

  • PDF