• Title/Summary/Keyword: 가스온도

Search Result 3,261, Processing Time 0.026 seconds

Non-gray Radiation in the Entrance Region of a Smooth Tube (평편한 튜브의 입구 영역에서의 비회복사)

  • Seo, Tae-Beom
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.91-103
    • /
    • 1995
  • Non-gray radiation with convection in the entrance region of a smooth tube is numerically investigated. The fluid is a mixture of carbon dioxide, water vapor, and nitrogen to simulate combustion products of propane. The flow is assumed to be laminar and hydrodynamically and thermally developing. The P-1 approximation is used to simplify the radiative transfer equation and the exponential wide band model is adapted to model the spectral absorption coefficients of non-gray gas mixture. The bulk mean temperature and Nusselt number variation along the tube axis are shown for several inlet and wall temperature pairs to show the effect of temperature on the heat transfer characteristics. Nusselt numbers for simultaneously developing flow are compared to those for thermally developing flow. In addition, the effect of the mole fraction of the non-gray gases on convective and radiative Nusselt numbers is investigated.

  • PDF

Solubility of Methane in Poly(n-Butyl Methacrylate) at Elevated Pressures (Poly(n-Butyl Methacrylate)에 의한 메탄가스의 용해도)

  • ;;;Stern, S. A.
    • Membrane Journal
    • /
    • v.2 no.2
    • /
    • pp.129-134
    • /
    • 1992
  • The solubility of methane in poly(n-butyl methacrylate)(PnBMA) was determined at pressures up to 35 atm. These measurements were made by volumetric technique in the temperature range from -10 to 30$^{\circ}$C. The solubility was found to be a nonlinear function of the applied pressure and could be satisfactorily described by dual-mode sorption model at temperatures below the glass txansition temperature($T_g$) of the polymer. The Langmuir capacity constant decreased with increasing temperature and vanished near the glass transition temperature of PnBMA. The solubility isotherm became linear at temperatures above the glass transition temperature of PnBMA. The temperature dependence of the dual-mode sorption parameters was also discussed.

  • PDF

Combustion Performance Test of Syngas Gas in a Model Gas Turbine Combustor - Part 2 : NOx/CO emission Characteristics, Temperature Characteristics and Flame Structures (모델 가스터빈 연소기에서 합성가스 연소성능시험 - Part 2 : NOx/CO 배출특성, 온도특성, 화염구조)

  • Lee, Min Chul;Yoon, Jisu;Joo, Seong Pil;Yoon, Youngbin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.8
    • /
    • pp.639-648
    • /
    • 2013
  • This paper describes on the NOx/CO emission characteristics, temperature characteristics and flame structures when firing coal derived synthetic gas especially for gases of Buggenum and Taean IGCC. These combustion characteristics were observed by conducting ambient-pressure elevated-temperature combustion tests in GE7EA model combustor when varying heat input and nitrogen dilution ratio. Nitrogen addition caused decrement in adiabatic flame temperature, thus resulting in the NOx reduction. At low heat input condition, nitrogen dilution raised the CO emission dramatically due to incomplete combustion. These NOx reduction and CO arising phenomena were observed at certain flame temperature of $1500^{\circ}C$ and $1250^{\circ}C$, respectively. As increasing nitrogen dilution, adiabatic flame temperature and combustor liner temperature were decreased and singular points were detected due to change in flame structure such as flame lifting. From the results, the effect of nitrogen dilution on the NOx/CO and flame structure was examined, and the test data will be utilized as a reference to achieve optimal operating condition of the Taean IGCC demonstration plant.

Gas Nitriding (가스 질소화)

  • 이상윤
    • Journal of the KSME
    • /
    • v.22 no.4
    • /
    • pp.308-315
    • /
    • 1982
  • 가스실화업은 페라이트 화학열처리(ferritic thermochemical treatment)로서 실소운자가 500-560.deg. C의 온도범위에서 페라이트상 내에 확산삼투되므로 실온까지 냉각할 시 상변태가 일어나지 않는다. 가스실화볍은 1920년대 처음으로 이용되었으며 그 이후로 이의 적용범위가 확대되어 현재는 상당히 많은 종류의 강에 적용되고 있다.

  • PDF

Numerical Study of Turbine Blade Surface Gas Temperature with Various RPM and Blade Edge Shape (터빈 블레이드 회전수 변화와 터빈 블레이드 엣지 형상 변화에 따른 표면 가스온도 분포 해석)

  • Lee, In-Chul;Byun, Yong-Woo;Koo, Ja-Ye;Lee, Sang-Do;Kim, Kui-Soon;Moon, In-Sang;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.49-52
    • /
    • 2008
  • The numerical analysis for gas temperature of turbine blade surface has been performed to investigate development of temperature with various blade edge shape. Two different types of the turbine which one is "Sharp" edge and the other is "Round" edge was modeled. Computations have been carried out several turbine rotational speeds in the range from 0 to 10,000 rpm for the each types of turbine edge shape. As a result, the more rotational speed of turbine increased, the more turbine blade's temperature decreased. It is also found that the surface temperature of turbine blades for sharp type edge were lower than the round type edge.

  • PDF

A Study on Effects of Temperature Difference between the Inside and Outside the Meter-Run on Natural Gas Flow Measurement Errors (천연가스 계량배관 내$\cdot$외의 온도차가 계량오차에 미치는 영향에 관한 연구)

  • Ha Youngcheol;Lee Chulgu;Chang Seungyong;Lee Kangjin
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.83-89
    • /
    • 1998
  • Experiments had been conducted Qualitatively regarding flow measurement errors of orifice flowmeter due to temperature difference between the inside and outside the natural gas meter-run in case of no pipe insulations. The primary factors considered in this study are fluid velocity and surrounding temperature. In addition, a portion of thermal radiation due to the sun was involved as a factor. The results showed that the considerable errors were not detected even in conditions of low flow rates and large temperature difference between the inside and outside the meter-run.

  • PDF

Test Results of Composite Cylinder Surface Temperature change between Pool Fire and Single Impinging Jet Flame Exposure Condition (전체 화염 및 단일 화염 노출 조건에서 복합재료 용기 표면 온도 변화 비교)

  • Lee, Jae-Hun;Hwang, Jun-Ho;Kim, Young-Seop;Kim, Hyo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.648-651
    • /
    • 2009
  • 탄소섬유강화플라스틱(CFRP:Carbon Fiber Reinforced Plastic)용기의 외부에 화재가 발생할 경우 함침된 수지(Resin)가 탄화되면서 자체 강도가 약화되고 충전된 가스가 외부 온도 상승에 따라 압력 상승이 발생하여 용기의 폭발로 이어지는 사고가 발생할 개연성이 높다. 화염 노출조건에서 복합재료 용기의 폭발을 방지하기 위하여 용기용 밸브에 내장된 온도감응식 압력안전장치(TPRD:Thermally activated Pressure Relief Device) 작동 성능을 검증하기 위한 방법으로 화염실험(Bonfire test)를 실시하고 있으나, 개방 공간에서 실시되는 이 실험은 표면 온도 변화가 매우 크게 발생하여 실험에 대한 재현성(Reproducibility)에 의문이 제기되고 있다. 따라서, 표면 온도를 일정하게 유지하기 위한 실험 방법의 개선이 필요하다. 본 연구에서는 경유+heptane을 이용한 전체 화염에 노출되는 경우와, 천연가스를 이용한 단일화염에 노출되는 경우의 실험 결과 비교를 통하여 화염 노출 표면 온도를 일정하게 유지하기 위한 가열 방법의 타당성을 검토하였다. 또한, 복합재료 라이너(Liner)의 온도 변화 비교를 통하여 집중화염 노출 조건에서 열전달 특성을 알아보았다.

  • PDF

Prediction of Pressurant Mass Requirement for Propellant Tank with Operating Condition Variation (운용조건 변화에 따른 추진제탱크 가압가스 요구량 예측)

  • Kwon, Oh-Sung;Han, Sang-Yeop;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.54-62
    • /
    • 2011
  • The pressurant mass required for propellant tank pressurization with operating condition variation was estimated by using the numerical model already developed for this purpose. The model was applied to the concept design results of KSLV-II first stage oxygen tank. The supplied pressurant temperature, oxygen volumetric flow rate, and the ratio of length to diameter of the tank were selected as variables. The required pressurant mass and mass flow rate, collapse factor, ullage temperature distribution were predicted, and the results showed that the pressurant temperature had the largest effect on the amount of the required pressurant mass. The pressurizing efficiency of the propellant tank was calculated through analyzing energy distribution in the ullage. It was found that the gas-to-wall heat transfer in the ullage was dominant, and much of the pressurant energy was lost to tank wall heating.

Role of Plant Extracts to Remove Hydrogen Sulfide in the Air-Lifter Reactor (Air-lift 반응기내 황화수소제거시 식물정유추출물의 역할)

  • Park, Jong-Woo;Park, Young-G.;Kim, Jeong-In
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.421-428
    • /
    • 2010
  • This paper reports on the experimental investigation carried out to evaluate the physical optimal conditions in the absorption column to remove odorous hydrogen sulfide gas. Hydrogen sulfide gas, as a highly undesirable contaminant, is most widely emitted from environmental treatment facilities. The absorbent mixed with natural second metabolites extracted from conifer trees and chemical absorbent of 2-aminoethanol was applied to remove it via chemical neutralization. The absorbent of natural second metabolites was achieved by a removal efficiency of 20-40% by itself depending on the treatment conditions, but the complex absorbent mixed with 0.1% amine chemical provides the removal efficiency of 98%. The optimal removal efficiencies have been examined against the two major parameters of temperature and pH. This study shows that the aqueous solution by natural second metabolites can be used as an appropriate absorbent in the column absorbed for the removal of hydrogen sulfide gas.

Electrical Property Changes of $\textrm{NO}_X$ Sensitive $\textrm{WO}_3$ Thin Films as Applied DC Voltages on 8YSZ Substrate (8YSZ 기판에 증착한 $\textrm{WO}_3$ 박막의 DC 전압에 따른 $\textrm{NO}_X$ 감지특성)

  • 전춘배;박기철
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.8-12
    • /
    • 1999
  • $\textrm{WO}_3$ semiconductive film, which is known to have a sensitivity on $\textrm{NO}_X$ gas was prepared on 8YSZ (8% Yttria stabilized $\textrm{ZrO}_2$) ionic conductor substrate that has oxygen ion pumping effect. Microstructure and electrical properity, especially $\textrm{NO}_X$ sensitivity as a function of DC voltage applied to 8YSZ substrate was examined. When the $\textrm{WO}_3$ film was annealed, it showed amorphous structure, while crystallization was occurred at $600^{\circ}$C revealing orthorhombic phase of $\textrm{WO}_3$. As the annealing temperature increases, (111) and (001) peaks of $\textrm{WO}_3$ film was enhanced. At $400^{\circ}C$ when DC voltage was applied, comparing with no DC bias, more stable and large response characteristics was showed, and the best sensitivity was observed at 2V. Recovery characteristics of NO gas was much better that that of $\textrm{NO}_2$ gas.

  • PDF