• Title/Summary/Keyword: 가스밸브

Search Result 417, Processing Time 0.03 seconds

Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve (가스밸브의 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.70-75
    • /
    • 2017
  • This paper presents the FEM analysis results on the deformation behavior safety of automatic cut-off horizontal and conventional vertical gas valves. Based on the FEM analysis, the primary maximum deformation of $4.4{\mu}m$ was formed on the right end side of a valve body when the internal gas pressure was supplied on the screw port and gas discharge port of an automatic cut-off horizontal gas valve. And the secondary maximum deformation of $2.9{\mu}m$ was formed on the end side of safety valve port. This small deformation of an automatic cut-off horizontal gas valve is strongly related to the balanced design of a horizontal gas valve main body, which is composed of a screw part, gas outlet port, port for a stem and spindle shaft assembly, and safety valve port. But, the primary maximum deformation of 0.076mm was formed on the upper part of a conventional automatic cut-off vertical gas valve when the internal gas pressure was supplied on the screw port and gas discharge port. And the secondary maximum deformation of 0.055mm was formed on the left end side of a gas outlet port. This may effect on the sealing clearance of o-ring that is inserted on the groove of an automatic cut-off unit. Thus, this paper recommends an automatic cut-off horizontal gas valve compared with that of a conventional gas valve for a gas leakage free mechanism of a LPG cylinder valve.

Optimization Design of a Gas Valve for a LPG Cylinder Using a Taguchi's Experimental Method (다구찌 실험법을 이용한 액화석유가스 용기용 밸브의 최적설계에 관한 연구)

  • Kim, Chung-Kyun;Oh, Kyoung-Seok
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.23-28
    • /
    • 2006
  • This paper presents the strength safety and the weight reduction analysis of nine gas valve models for a LPG cylinder using a finite element analysis program, MARC and Taguchi's experimental method. The maximum Von Mises stress of a gas valve body represents a safety of a brass valve structure for the given gas pressure of $91kg/cm^2$, which considered a safety factor of a LPG gas cylinder. The weight reduction analysis is very important for reducing a gas flow friction loss and a manufacturing cost as a design parameter. The calculated results present an design model 9 as an optimized design data with 10mm radius of a lower part gas flow pipe A, 6mm radius of an upper part gas flow pipe B and a connecting length 2 mm of tapered pipe D between lower and upper pipes.

  • PDF

A Study on the Development of Overflow Cutoff Valve for Liquefied Petroleum Gas Cylinders (액화석유가스 용기용 과류차단밸브의 개발에 관한 연구)

  • Rhim Jong-Kuk
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.158-161
    • /
    • 2005
  • This research is about overflow cutoff valve for liquefied petroleum gas cylinders. This valve was developed based on Bernoulli's equation and Newton's equation. The structure of overflow cutoff valve was made by insert module instead of the ordinary valve that is used at present. Recently, the increase in use of gas for fuel in houses has resulted to more frequent occurrences of gas related accidents. In Korea, the government has made a law for the obligatory use of the cutoff valves. This cutoff valve is not ya developed. This research focuses on the use of over flow cutoff valve for LPG cylinders. If this valve is adapted, many accidents can be prevented.

A Study on the Modified Safety Valve for Vessels of Liquefied Petroleum Gas (LP가스 용기용 안전 밸브 개발에 관한 연구)

  • Rhim Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.38-42
    • /
    • 2005
  • This study introduced concept of safety valve about development of valve for LP gas cylinders. LP gas cylinders are used more because of convenience of use, but a lot of accidents are occurred. Specially, it is used by purpose to injure glossary or others and is sometimes used to a demonstration tool. Korean government was making mandatory to use overuse cutoff valve to reduce accident, but it is real condition that product development is not following. In this study, introduce concept of safety valve that introduce more original safety concept than overuse cutoff valve. This was developed by method that insert module to present use valve and flowing of gas is controlled in state that hose or regulator un-connects to valve. Also, flowing of gas cut-off immediately if hose is cut or occurrence of overuse is produced even if is using normally.

  • PDF

Development of Performance Test Procedure for the Excess Flow Valve for Buried Piping for the Domestic LPG Mass Supply System (국내 LPG 집단공급시설 환경에 적합한 매몰배관용 과류차단밸브 성능시험 절차 개발)

  • Jang, Chanyeong;Lee, Ugwiyeon;Lee, Jinhan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.16-27
    • /
    • 2018
  • Since 2014, the Korean government has begun distributing LPG pipelines and LPG tankers to mountainous or island areas where it is difficult to open urban gas supply chains. When installing LPG supply facilities at village level and county level, it supplied consumers with 10 times higher quasi-low pressure (25 kPa to 100 kPa) than conventional gas supply pressure, increasing the risk of gas accident. Due to the pressure that is 10 times higher than the conventional gas supply pressure, large amounts of gas are released at a faster rate when leaked. In order to secure safety of quasi-low-pressure gas pipes, excess flow valves for quasi-low-pressure gas pipes are not developed and are not supplied in Korea. Therefore, Korea Gas Safety Corporation is investigating the performance standards and products of the excess flow valves in order to localize the excess flow valves.

액화석유가스 20kg용기의 가스누출량에 대한 실험적 연구

  • Lee, Jang-U;Park, Chan-Ok;Yeo, Chang-Hun;Park, Chan-Il
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.4 no.1
    • /
    • pp.82-85
    • /
    • 2004
  • 본 연구는 가스사고의 전형적이고 대표적인 폭발사고와 관련하여 LP가스용기밸브 압력정기, 중간밸브(볼밸브) 및 염화비닐호스로부터의 가스누출량이 어느 정도 되는지에 대하여 이론적으로 계산한 가스누출량과 실제 가스누출량에 대하여 실험을 통하여 연구함으로서 체적공간에서의 폭발과정과 점화원 및 사고경위를 조사하는데 중요한 자료로 활용하고 의도적이거나 취급 또 시공상의 부주의에 의한 가스누출 발생시 사고당시 가스누출량을 확인하는데 활용하고자 연구하게 되었다.

  • PDF

A Study on the Strength Safety of a Gas Valve (가스밸브의 강도안전성에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.60-63
    • /
    • 2018
  • This paper presents the FEM analysis results on the strength safety of a gas valve for a LPG cylinder. Based on the FEM analysis, the maximum von Mises stress on the boundary zone between a safety valve and the upper area of the thread is 99.2 MPa for the supplied gas pressure of 3.5 MPa in which the gas valve is fully opened. The maximum von Mises stress of 99.2 MPa is considered as safety value, because that value is lower than the yield stress of a brass material. In this case, the maximum deformation at the upper right part of the pressure regulator is 0.002mm. The maximum deformation zone is not a meaning part of the sealing part such as an O-ring or a diaphragm of a gas valve and a pressure regulator. The proposed hybrid gas valve model in which is integrated with a conventional cut-off valve and a pressure regulator is recommended as a gas leakage free mechanism and minimized compact size for a LPG cylinder.

Experimental Study on the Safety of a Valve for a Special Gas Cylinder (특수가스용기용 밸브의 안전성에 관한 실험적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.14-19
    • /
    • 2013
  • This paper presents an experimental study on the safety of a valve for a special gas cylinder. The test valves that were randomly dismantled from the special gas cylinder were experimented on the gas leakage and operation safeties. The crack, wear and deformation of the valve body, screw thread, safety disk, vent hole, stem and handle components that may affect to the gas leakage safety of a used valve were not found in this experimental study. A painted handle of a valve was partly stripped from the coated surface, and the surface of PT screw of a used valve body was rusted. But, these paint and rust problems do not affected to the gas leakage safety of used valves. And there was no gas leakage in the dismantled valve, and the permanent deformation and partial scars of a valve stem and O-rings were observed on the rubbing surfaces. Thus, the valve seat and O-rings are recommended to be replaced for a gas leakage safety of a dismantled valve. And it is necessary to repair and inspect handle fastening forces for a safe opening and closing operations of a valve.

Development of Degassing Valves for Food Packaging using Ring Type Rubber Disk (링타입 고무막을 이용한 식품 포장용 가스배출 밸브(Degassing Valve) 개발)

  • Yu, Ha Kyoung;Lee, Kyungo Ho;Oh, Jae Young
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.2
    • /
    • pp.35-39
    • /
    • 2014
  • One-way degassing valves are designed to allow pressure to be released from an air-tight package while preventing air from getting back into the package. Air, especially the oxygen ($O_2$) portion of air, can have negative effects on the package contents and its freshness. The most common application of the one-way degassing valve is for fresh roasted coffee. Demands of one-way degassing valves have been increasing with the high growth of global coffee market. In this study, we have developed one-way degassing valves for coffee and food packaging using ring type rubber disk, named SP valve. Its quality and performance was verified with test results to be equal with that of global top maker's product, Goglio valve. SP valves showed 820~1200 Pa of opening pressure, 10~50 Pa of closing pressure, 1.2~1.6 L/ min of flow rate. And, the SP valve applicable to ferment food packaging is expected to contribute to globalize Korean traditional food.

  • PDF

가스정책(2) - 가스누출확인배관용밸브, 은폐배관 점검구 대체 가능

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.295
    • /
    • pp.93-95
    • /
    • 2015
  • 지난 2013년 7월 25일 도시가스사업법 시행규칙 개정에 따라 도시가스 은폐배관 설치 시 천정에 가스누출점검을 위한 점검구를 뚫거나 값비싼 다기능가스안전계량기를 설치해야 한다. 이에따라 수많은 민원이 발생하여 대한설비건설협회(이하 협회)는 실내 미관을 위해 점검구의 크기를 축소하고, 가스누출 점검을 위한 대체방법으로 다기능가스안전계량기 뿐만 아니라 가정에서 저렴하게 설치할 수 있는 가스누출확인배관용밸브 설치도 허용해 줄 것을 건의해 왔다. 협회 건의에 대해 가스기술기준위원회는 지난 1월 27일 질의회신을 통해 가스누출확인배관용밸브 설치 시 은폐배관의 가스누출이 탐지 가능하므로 가정 내에서 이 밸브를 설치할 경우 점검구를 뚫지 않아도 된다고 회신했다.

  • PDF