• Title/Summary/Keyword: 가변유량시스템

Search Result 40, Processing Time 0.024 seconds

가스 엔진 VRF시스템의 에너지 실사용량 & 시뮬레이션 평가와 전기 구동 VRF 시스템과의 성능비교에 관한 연구 (Evaluation of actual Energy consumption & Simulation of Gas Engine VRF System and Comparison with Electric VRF System)

  • 최슬건;전종욱;김강수
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.67-74
    • /
    • 2017
  • Purpose: As the recent climate environment changes so rapidly, environmental problems such as hot weather and fine dust have occurred, and interest in environmental policies and technology development is increasing in countries around the world. Similarly in the Architecture, researches to reduce greenhouse gas emissions and to reduce energy application are actively conducted. Looking at previous studies, it is analyzed that the electric VRF is more energy efficient than the gas engine VRF. However, energy costs have changed due to recent price hikes and discounts on gas charges due to high electricity consumption in summer. Method: In this study, the actual building of Gas Engine VRF system was modeled using SketchUp program, and EnergyPlus was used to simulate actual building. Also, Electric VRF system was simulated, and compared with Gas Engine VRF system. Result: The total secondary energy requirement of Electric VRF system was 19.6% less than that of the Gas Engine VRF system, But when analyzing with primary energy requirement, EHP used 15.8% more energy. CO2 emissions were also estimated to be 16.9% more EHP. Energy costs were 14.8% more in Electric VRF systems, because their electricity charges are 0.6 to 160% more expensive than gas charges.

난류충돌유동의 질량유량비에 따른 혼합유동구조에 관한 실험적 연구 (An Experimental Study on the Mixing Flow Structure of Turbulent Cross Flow with Respect to the Ratio of Mass Flow Rate)

  • 이대옥;노병준
    • 대한기계학회논문집
    • /
    • 제16권11호
    • /
    • pp.2150-2158
    • /
    • 1992
  • 본 연구에서는 복잡한 유동형태를 지닌 충돌분사류에 대한 유동특성을 연구하 기 위하여 단순화된 실험모델로써 형상이 동일한 두 원형분류의 충돌에 의한 충돌분류 의 혼합현상 및 유동구조 등을 질량유량비의 변화에 따라 유체역학적으로 구명하고자 하였으며, 본 연구 결과는 연소기관에서의 연소효율 증대 및 구조개선등의 공학적 응 용을 위한 기본자료로 활용하고, 이론적 연구에 의한 난류의 유동구조 및 유동특성 에 대한 타당성 입증과 이론적 모델의 보완을 위한 실험자료로 이용하고자 한다. 충돌유동에 영향을 미치는 주요인자는 노즐직경, 충돌각, 충돌질량유량비, 온도, 밀도 등이며, 이 인자들 중에서 충돌질량유량비와 출돌각이 충돌후 형성되는 난류혼합유동 에 지배적인 영향을 미치므로, 본 연구에서는 두 원형분류의 충돌질량유량비를 가변할 수 있는 장치를 고안하였으며, 두 분류의 충돌각을 45˚로 고정하고, 고속측과 저속측 노즐의 질량유량비를 1.0, 0.8, 0.6, 0.4로 설정하여 질량유량비에 따른 혼합 유동구 조의 구명을 위한 실험적인 연구를 수행하였다. 충돌후의 혼합유동의 특성을 연구하 기 위하여 유동중심궤적, 유동반폭, 유동단면, 2차원 및 3차원 유동장, 평균속도분포 등을 온라인 컴퓨터시스템을 이용하여 측정분석하였다.

PSO를 이용한 물 재이용 펌프시스템의 에너지 비용 제어 (Energy Cost Saving Control of Water Reuse Pumping System Using Particle Swarm Optimization)

  • 부창진;김호찬;강민제
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.860-867
    • /
    • 2015
  • 본 논문은 PSO 알고리즘을 이용하여 물 재이용 펌프 시스템의 에너지비용을 최소화 할 수 있는 방법을 제안한다. 1시간 단위의 시간대에서 펌프제어를 위해 계시별 요금제를 기반으로 하여 최적화 구간을 설정하고 PSO알고리즘을 이용하여 에너지 비용을 절감할 수 있도록 펌프동작을 제어한다. 물 재이용 펌프시스템에서 고정된 유량을 출력하는 펌프와 입력전력을 가변할 수 있는 펌프에 대해 TOU 기반에서 에너지 비용을 최대로 줄일 수 있도록 시스템을 동작시킨다. 시뮬레이션을 통해 제안한 에너지 비용 절감 방법이 기존 수위기반의 제어방법보다 비용을 절감할 수 있음을 확인할 수 있다.

EHA용 가변용적형 사판식 유압 피스톤 펌프의 하이브리드 제어 (Hybrid control of the swash plate-type variable displacement hydraulic piston pump for an EHA)

  • 권용철;홍예선
    • 한국항공우주학회지
    • /
    • 제41권4호
    • /
    • pp.291-298
    • /
    • 2013
  • 본 논문에서는 압력보상형 사판식 유압 피스톤 펌프와 밸브 제어형 실린더를 결합한 EHA에 대하여 유압 실린더의 소비 유량이 작으면 펌프 회전 속도를 낮추는 새로운 개념의 하이브리드형 제어 시스템을 제안하였다. 펌프 내 압력조절기의 사판각 제어와 간섭을 피하기 위해 위치 명령 신호의 속도 성분 평균치를 이용하여 펌프의 회전속도를 조절하였고, 시스템 압력이 기준치 이하로 낮아지는 것을 방지하기 위해 압력 스위치 기능을 추가하였다. 시뮬레이션과 실험 결과에 의하면, EHA의 동적인 응답 특성에 영향을 주지 않는 조건에서 하이브리드 제어를 통해 공전 모드에서의 펌프 회전속도를 1,800rpm에서 600rpm로 낮춤으로써 하이브리드 제어를 안 할 경우에 비해 펌프 구동 동력을 약 44%까지 절감시킬 수 있음을 확인하였다.

하수처리장 적용을 위한 Semi-카플란 수차가 장착된 마이크로수력발전 시스템: 기흥레스피아 사례 (Micro-Hydropower System with a Semi-Kaplan Turbine for Sewage Treatment Plant Application: Kiheung Respia Case Study)

  • 채규정;김동수;천경호;김원경;김정연;이철형;박완순
    • 대한환경공학회지
    • /
    • 제35권5호
    • /
    • pp.363-370
    • /
    • 2013
  • 소수력발전은 하수처리장 에너지 자립을 위한 효과적인 대안이다. 본 연구는 유량변동이 크고 유효낙차가 낮은 중소형 하수처리장(기흥레스피아) 적용을 위해 피치조절형 세미카플란(semi-kaplan) 마이크로수력발전의 적용 타당성을 평가하였다. 가변피치 semi-kaplan 수차는 유량조절을 위한 가이드베인은 생략하고 피치조절형 런너를 장착하여 기계적 결함은 줄이면서 유량변동이 큰 처리장에 특화된 기술이다. 마이크로수력발전 시스템은 설계조건(유량 0.35 $m^3/s$, 유효낙차 4.7 m)에서 90.2%의 수차효율 달성이 가능하였고 발전용량은 13.4 kW로 산정되었다. 설비가동률 74%로 가동 시 연간 약 86.8 MWh 에너지 생산을 통해 2.1%의 에너지 자립이 가능하고 이는 연간 49톤의 $CO_2$ 감축효과와 맞먹는다. 경제성 평가결과 초기 건설공사비가 200,000,000원 이하인 경우에는 내부수익률은 6.1%, 순현가는 15,539,000원, 편익-비용률은 1.08, 투자회수년은 15.5년으로 경제성이 충분한 것으로 나타났다.

형상기업합금을 이용한 유량제어밸브의 위치제어 적용 시뮬레이션 (A Simulation Study of Position Control Performance of a Shape Memory Alloy-Actuated Flow Control Valve)

  • 최수현;이한석;국금환
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.79-87
    • /
    • 1999
  • In this study, a new type of flow control valve which is SMA actuated flow control valve is presented. The flow control valve is actuated by a small motion of shape memory alloy. The performance of this valve as a position control component is analyzed by computer simulation. A variable structure control technique is applied for the position control by the flow control valve. The position control performance of the valve is evaluated on the step responses of a PID control by a electrohydraulic servo valve. For the simulation study, first, the mathematical model of a hydraulic system, which is consisted of the flow control valve and a hydraulic cylinder, is formulated. This mathematical model and the designed variable structure control algorithm are then combined by the MATLAB software. The same sequence of work is carried out for the PID position control system with a electrohydraulic servo valve. The simulation results show the validity of the new type of flow control valve as a variable position control component.

  • PDF

가변 유입유량 공정시스템에 대한 상태방정식을 이용한 체재시간분포 해석 (Analysis of the Residence Time Distribution for a Variable Feed Rate System by the State-space Equation)

  • 문진호;정성희;김종범
    • 방사선산업학회지
    • /
    • 제4권1호
    • /
    • pp.85-89
    • /
    • 2010
  • The radioactive experiments are carried out for diagnosis of a variety of industrial processes in terms of the operation condition and the efficiency by measuring the residence time distribution. However, it is not easy to interpret the residence time distribution using the conventional methods when the flow rate is not constant and a number of processes are coupled in a complicated manner. In these cases, they can be analyzed by describing the system with mathematical models that can be defined with the state-space equations. In this paper, the residence time distribution of sludge was measured with a radiotracer, $^{46}Sc-EDTA$, in the digester of which the flow rate varies with time. The digester was assumed as a linear time variant system since the flow rate changed during the experiment and the operation efficiency of the digester was calculated by applying the state-spae equations.

불완전연소 가스발생기 연소특성 연구 (Combustion Characteristics of Fuel-rich Gas Generator)

  • 최호진;현형수;변종렬;박의용;윤현걸;임진식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.375-378
    • /
    • 2011
  • 덕티드로켓 추진기관에 사용되는 불완전연소 가스발생기를 설계/제작하고 연소시험을 수행하여 그 연소특성을 분석하였다. 추진시스템 설계요구조건을 바탕으로 가스발생기를 설계하고 산화제 함유량을 줄이고 금속연료 함량을 증가시킨 불완전연소용 고체연료 조성을 개발하여 가스발생기를 제작하였고, 이를 이용한 연소시험을 통해 다상 유동의 불완전연소 가스가 존재하는 가스발생기의 성능예측을 위해서는 별도의 해석기법이 요구됨을 확인하였다.

  • PDF

적층액츄에이터형 초음파 노즐을 이용한 경유분사 시스템의 구동특성 (Driving Properties of Diesel Injection System using the Multilayer Actuator Structured-ultrasonic Nozzle)

  • 김도형;김화수;강진희;이유형;황락훈;류주현;홍재일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.174-174
    • /
    • 2008
  • 초음파를 이용하여 액체 연료를 분사하면 균일한 입경과 미립화가 우수하며 에너지 절약과 공해방지등을 할 수 있다. 또한 유속과 유량에 관계없이 이용할 수 있어 반도체 분야의 웨이퍼와 평판 표시기상에 사진 석판용 화학물질의 균일도포 컴퓨터 하드 디스크의 광택제 도포등에 사용할 수 있다. 이처럼 초저의 유출 용량을 요구하는 모든 공정 및 액체연료의 분사가 요구되는 모든 산업에 적용할 수 있는 장점을 가지고 있다. 하지만 현제까지 주로 사용되고 있는 초음파노즐의 액츄에이터는 단판액츄에이터형로 높은 교류전압을 인가해주어야 하는 단점을 가지고 있다. 이 단점을 해결하기 위해 적층액츄에이터형을 사용하여 초음파 노즐 구동하면 낮은 교류 입력전압에서도 단판액츄에이터형 초음파 노즐과 같은 특성을 가질 수 있다. 또한 초음파 노즐의 구동시 기계적인 진동을 이용하므로 많은 열을 발생시켜 노즐의 온도가 상승하여 세라믹 액츄에이터에도 그 영향을 미치게 되어 열적 열화 현상이 일어날 수 있기에 높은 큐리온도를 가지는 액츄에이터가 필요하다. 본 실험에서는 $Pb(Mn_{1/3}Nb_{2/3})_{0.02}(Ni_{1/3}Nb_{2/3})_{0.12}(Zr_{0.50}Ti_{0.50})_{0.86}O_3$ 조성을 사용하여 $900^{\circ}C$의 저온에서 액상 소결하여 적층혈액츄에이터를 제작하였으며 압전 및 유전 특성을 조사하였다. 제작된 초음파노즐을 구동하기 위해서는 약 36kHz의 30V이상의 교류입력전압 할 수 있는 구동회로가 필요로 한다. 압전액츄에이터의 구동을 위해서는 정확한 정현파 입력이 필요 없다. 압전액츄에이터의 특성상 유사 정현파 입력 만으로도 임피던스 매칭이 이루어지기 때문에 설계가 쉽고 간편한 Push-Pull 방식을 이용한 PWM인버터를 사용하였고 인버터의 출력 주파수를 34~38kHz까지 가변 할 수 있게 설계하였다. 제작된 적층액츄에이터형 초음파 노즐을 PWM인버터로 실제 액체 연료인 경유를 분사하였을 때의 액츄에이터의 온도 변화에 따른 공진주파수와 온도 의존성, 전기적 특성을 조사하고 미립화 분사되는 경유의 미립자 크기 및 최대 분사량을 조사 하였다.

  • PDF

지형학적 순간단위도(GIUH)에 의한 강우-유출해석 (A Study on Rainfall-Runoff Analysis by Geomorphological Instantaneous Unit Hydrograph (GIUH))

  • 최흥식;박정수;문형근
    • 한국방재학회 논문집
    • /
    • 제6권1호
    • /
    • pp.49-58
    • /
    • 2006
  • 본 연구는 미계측이나 자료가 결핍된 유역에서 지리정보시스템을 이용하여 유역의 지형학적 매개변수를 얻어 유도된 지형학적 순간단위유량도에 의한 강우-유출의 특성을 분석하였다. 횡성댐 상류 섬강시험유역에서 얻어진 실측자료를 사용하였고, 직접유출을 분석하기 위하여 가변기울기법을 이용하였다. 아울러 4차 하천유역인 섬강시험유역은 Horton-Strahler의 차수법칙에 따라 일정한 규칙을 가지고 발달한 수계임을 확인하였다. GIUH의 사용에 따른 섬강시험유역의 규모계수 결정식의 변형을 하였고, 유출특성속도는 1.0m/s으로 나타났다. 4차 하천유역인 섬강시험유역의 출구인 매일교수위국과 3차 하천유역의 출구인 소군교와 농거리교수위국에서의 GIUH에 의한 수문곡선은 첨두시간이후의 유역의 저류능에서 약간의 차이를 보이나, 실측값과의 비교에서 잘 일치하였다. 아울러 유역을 보다 세분화하여 적용한 GIUH모형에 의한 수문곡선을 상류유입수문곡선으로 하여 HEC-HMS를 이용하여 수문 추적한 결과가 전체유역을 대상으로 한 GIUH모형에 의한 수문곡선보다 실측치에 잘 일치하였다. 전반적으로 GIUH에 의한 강우-유출해석은 미계측 유역에 사용성이 있는 것으로 평가된다.