• Title/Summary/Keyword: 가변압축기

Search Result 106, Processing Time 0.025 seconds

Performance of Compressor with Variable Capacity (용량가변 방식을 적용한 압축기의 성능연구)

  • 권영철;진의선;허삼행;김대훈;홍주태;문제명
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.214-218
    • /
    • 2004
  • In the present study, the variation of input power and efficiency improvement of a scroll compressor applying PWM method are experimentally investigated. The cooling capacity, input power and COP are measured under the cooling operation. The input power due to the change of the condenser and the coil addition in a main current part is measured to enhance the compressor efficiency. Measured results show that the input power and COP increase with increasing the tooling capacity. And the minimum input power of the compressor is observed. By the adoption of the double system, the consumption of compressor input power is reduced, compared with the existing system.

Effects of Variable Guide Vane Setting Angle on the Performance of Multi-Stage Axial Compressor (가변안내깃 설치각이 다단 축류압축기 성능에 미치는 영향)

  • Park, JunYoung;Seo, JeongMin;Lim, HyungSoo;Choi, Bumseok;Choi, Taewoo;Choi, Jaeho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.5
    • /
    • pp.9-18
    • /
    • 2016
  • Generally the variable guide vane is used to secure the sufficient operating point in the off-design condition. In this study the inlet guide vane, 1st and 2nd stators in a multi-stage axial compressor are movable to obtain the operating range. So the effects of variable guide vane setting angle on the performance of 2.5 stage axial compressor were investigated at 70 % and 90 % conditions of nominal rotating speed in this paper. The steady-state and unsteady numerical analyses were conducted at each operating condition. The performance map, lost efficiency and flow fields were compared.

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF

A Study on the Performance Prediction Method for an Axial Compressor with Variable Inlet Guide Vane (가변 입구 안내익이 있는 축류압축기의 성능예측 방법에 관한 연구)

  • Kim, Dong-Hyun;Kim, Sang-Jo;Kim, Kui-Soon;Son, Chang-Min;Kim, You-Il;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, numerical method, stage stacking method based on the result of numerical method and scaled stage stacking method have been applied to predict the performance of a multi-stage axial compressor with inlet guide vane. The results obtained through three different methods for off-design conditions were compared with performance test data. And the effect the angle of variable inlet guide vane was also investigated. The three-dimensional numerical simulation has been performed by using flow analysis program, $FLUENT^{TM}$ 6.3 and the performance prediction based on the stage stacking method has been performed with compressor analysis code from NASA.

An Approach for the Integrated Performance Analysis of a Small Turbofan engine with Variable Inlet Guide and Variable Stator Vane (가변 안내익 및 정익을 가지는 소형 터보팬 엔진의 성능예측을 위한 통합 해석법 연구)

  • Kim, Sang-Jo;Kim, Dong-Hyun;Son, Chang-Min;Kim, Kui-Soon;Kim, You-Il;Min, Seong-Ki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.23-32
    • /
    • 2012
  • The present study is aimed to develop an integrated performance analysis approach for the application of a compressor with variable inlet guide vane (VIGV) and vairable stator vane (VSV) in a small turbofan engine. For the integrated analysis approach, an engine performance analysis program, NPSS and a computer program used for predicting of axial flow compressor performance based on stage stacking method, STGSTK were linked with an optimisation package, Isight. This enables off-design performance analysis for the turbofan engine with VIGV and VSV hence provides the capability to predict stable operation condition of the engine with acceptable surge margin.

Design of Hardwired Variable Length Decoder for H.264/AVC (하드웨어 구조의 H.264/AVC 가변길이 복호기 설계)

  • Yu, Yong-Hoon;Lee, Chan-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.71-76
    • /
    • 2008
  • H.264(or MPEG-4/AVC pt.10) is a high performance video coding standard, and is widely used. Variable length code (VLC) of the H.264 standard compresses data using the statistical distribution of values. A decoder parses the compressed bit stream and searches decoded values in lookup tables, and the decoding process is not easy to implement by hardware. We propose an architecture of variable length decoder(VLD) for the H.264 baseline profile(BP) L4. The CAVLD decodes syntax elements using the combination of arithmetic units and lookup tables for the optimized hardware architecture. A barral shifter and a first 1's detector parse NAL bit stream, and are shared by Exp-Golomb decoder and CAVLD. A FIFO memory between CAVLD and the reorder unit and a buffer at the output of the reorder unit eliminate the bottleneck of data stream. The proposed VLD is designed using Verilog-HDL and is implemented using an FPGA. The synthesis result using a 0.18um standard CMOS technology shows that the gate count is 22,604 and the decoder can process HD($1920{\times}1080$) video at 120MHz.

Design of A 2.7-V MMIC SiGe HBT Up-converter and Variable Gain Amplifier for Cellular Band Applications (Cellular 주파수 대역 2.7-V MMIC SiGe HBT 상향 주파수 혼합기와 가변이득 증폭기의 설계)

  • 박성룡;김창우
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.146-149
    • /
    • 2000
  • SiGe HUT뜰 이용하여 Cellular 주파수 대역(824-849 MHz)에서 MMIC 상향 주파수 혼합기와 가변이득 증폭기를 설계하였다. 동작 전압은 2.7 V 이며, 이중평형 구조의 상향 주파수 혼합기는 12 dB의 변환이득, -0.6 dBm의 1dB 이득압축 출력전력, 30 dB 이상의 LO-RF 단자 격리도 특성, 1.25의 LO-VSWR. 1.34의 RF-VSWR을 가지며, 상호컨덕턴스형 가변이득 증폭기는 35 dB의 최대 선형이득, 13 dBm의 1dB 이득압축 출력전력, 42dB의 가변이득, 23dB의 3차 상호변조 교점 출력전력(OIP$_3$), 1.27의 입력 VSWR, 1.1의 출력 VSWR 특성을 보인다.

  • PDF

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree (전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성)

  • Beak, Seung-Moon;Moon, Choon-Geun;Kim, Hyun-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.282-288
    • /
    • 2010
  • The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.

Performance Analysis of Speech Recognition in Communication Systems using Speech Coder (음성 압축기를 사용한 통신 시스템에서의 음성 인식 성능 분석)

  • Han Sang-Wook;Jung Heui Suck;Park Hochong
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.179-182
    • /
    • 2002
  • 본 논문에서는 음성 압축기를 사용하는 디지털 이동통신 환경에서 한글 음성 인식기의 성능을 분석하기 위하여 다양한 표준 음성 압축기를 이용하여 음성 압축기의 구조, 전송률, 전송 채널의 에러율에 대한 성능을 측정하여 비교하였다. 동일한 구조의 음성 압축기에 대하여 전송률의 증가에 따라 음성 인식률이 증가하지만, 음성 압축기의 구조에 따라 동일 전송률에서도 많은 성능 차이가 발생하는 것을 확인하였다. 특히 IS-127 EVRC의 인식 성능이 매우 떨어지는 것을 알 수 있고, EVRC의 잡음 제거기와 가변 전송률에 의하여 음성 인식 성능이 저하되는 것을 확인하였다. 이를 통하여 청취 음질과 음성 인식 성능 사이의 상관 관계가 높지 않는 것을 알 수 있다. 모든 음성 압축기에 대하여 채널 에러율과 음성 인식기의 성능은 매우 밀접한 관계가 있음을 확인하였고, 평균적으로 채널 에러율 $1.0\%$에서 인식률이 $0.6\%$ 감소하고, 에러 $5.0\%$에서 인식률이 $1.8\%$ 감소한다.

  • PDF