• Title/Summary/Keyword: 脉诊

Search Result 112, Processing Time 0.026 seconds

Finite Element Analysis of Packaging Shape for Pulse Diagnosis Sensor (FEM 분석을 통한 맥진센서모듈의 패키징 형태와 응력분포)

  • Shin, Ki-Young;Lee, Sang-Sik;Joo, Su-Bin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.167-173
    • /
    • 2011
  • Since many blood pressure pulse analyzer made to measurement of a pulse wave in quantitative way has been started, some sorts of pressure sensors are being developed. The result could differ and this cause either type of sensor or module shape, when pulse wave is measured. In this paper, calculate and compare the pressure sensor's stress distribution according to thickness of PDMS coating and existence of guide through Finite Element Method. As a result, the center of pressure sensor's stress increase as much as 24% as it is reduced as much as 0.3 mm that the PDMS coating thichness of pulse diagnostic sensor module, on the other hand the surrouding censor of center sensor's stress is reduced as much as 4.9%, and transmissive proportion of stress is small as little as 2.7%, When coating has guide.

Extraction of Respiratory Rate by using FFT for Radial Artery Pulse Waves Acquisited by Clip-type Pulsimeter with a Hall Sensor (홀센서 집게형 맥진기 요골동맥파에 FFT를 적용한 호흡수 추출 연구)

  • Cho, Hyun-Sung;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.178-182
    • /
    • 2012
  • This research suggested that the extraction of respiratory rate could be made possible by using frequency analysis in the data process for clip-type pulsimeter equipped with permanent magnet and Hall sensor. The pulse analysis included of cardiac motion information depending on variation of pulse waveforms is investigated by means of Fast Fourier Transformation (FFT). The peaks of FFT spectrums measured at 15, 20, 30, 40, and 50 tempos are coincided to each respiratory rate having 0.125 Hz, 0.16 Hz, 0.25 Hz, 0.33 Hz, and 0.41 Hz, respectively. The FFT spectrum using algorithm for the extraction of respiratory rate showed the best pulse waves measured during 300 s. Based upon these results, the clip-type pulsimeter could extract the effective respiratory rate reflecting physical effects.

Simulation Analysis of Spatially Arterial Pulse Wave using Two-dimensional Array Sensors with Magnetoresistive Device (2차원 배열 자기저항소자를 이용한 공간 맥진파형의 전산모사 분석)

  • Kim, M.S.;Kim, S.W.;Kim, G.W.;Lee, S.J.;Lee, S.G.;Lee, H.S.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.307-310
    • /
    • 2005
  • To get the spatial feature of arterial pulse, we designed spatial pulse diagnostic apparatus (SPDA) using a 2-dimensional magnetoresistive sensor array. The magnetic field distribution fur magnet may was simulated using finite element method. We recognized that the field distribution of parallel magnet mays was more sensitive and uniformed than that of perpendicular one. Also the spatial displacements of magnet array were agreed with the output signal of magnetic tunnel junction (MTJ) sensor array.

The effect of the BMI on the automatic pulse dianosis in Korean Traditional Medicine (BMI가 한의맥 자동진단에 미치는 영향)

  • Lee, Yu-Jung;Lee, Hae-Jung;Lee, Jeon;Kang, Jae-Hwan;Lee, Si-Woo;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1904-1905
    • /
    • 2007
  • 한의학적 중요 진단방법의 하나인 맥진은 한의사 경험에 의해 구전되거나 전수되어 판단 기준이 모호하여 객관화 및 표준화하기 어려운 상황이다. 이를 위해 한의사가 맥진에서 측정하는 물리적 요소를 신뢰성 있게 측정할 수 있는 맥진기 개발이 진행되었으며, 측정된 맥진기 데이터를 이용하여 맥의 부/침, 허/실, 대/세의 정도를 판별할 수 있는 함수식을 만들어 향후 맥진을 자동으로 진단할 수 있도록 알고리즘을 산출하는 연구를 수행중이다. 그런데 맥진기는 환자의 맥파 신호 이외에 다른 정보를 고려하고 있지 않고 있지만 임상에서 한의사들은 환자의 키와 몸집 등 눈으로 관찰된 환자정보를 반영하여 맥진을 한다. 따라서 본 연구에서는 환자의 기초 정보 중, BMI가 맥진에 영향을 줄 것으로 가정하고, BMI와 연관성이 있을 것으로 예상되는 부/침, 허/실, 대/세의 판별함수 결과 값을 이용하여 BMI의 등급에 따라 비교 분석하였다. 그 결과 부/침의 정도는 비만인 그룹에서 맥이 가라앉아있고 저체중인 그룹에서는 맥이 떠있는 경향이 나타났고, 대/세의 정도는 비만인 그룹에서는 맥의 굵기가 넓고 저체중의 집단에서는 맥의 굵기가 좁은 경향이 나타났다. 따라서 부/침, 대/세를 판별하는 진단 알고리즘을 개발할 경우 개인의 BMI를 고려한 진단 알고리즘이 연구되어야 하겠다.

  • PDF

Ontology Representation of Pulse-Diagnosis Data and an Inference System for the Diagnosis Service (맥진 데이터의 온톨로지 표현과 진단 서비스 추론 시스템)

  • Yang, Dong-Il;Park, Sun-Hee;Lim, Hwa-Jung;Yang, Hae-Sool;Choi, Hyung-Jin
    • The KIPS Transactions:PartB
    • /
    • v.15B no.3
    • /
    • pp.237-244
    • /
    • 2008
  • In this paper, an infra-structure using the ontology based on the pulse information is proposed for the context-aware service of medical information system in ubiquitous computing environment. An diagnosis service inference system that represents the pulse data which was generated by the pulse-diagnosis with wearable signal, temperature, humidity, time, and other factors as ontology with artificial intelligence methods and describes the service scenario based on the ontology is designed and implemented.

A study for Oriental Medicine Pulse diagnosis of pulse wave analysis on left/right blood vessel (좌우 맥파분석을 통한 혈관특성 및 한의맥진연구)

  • Lee, Yu-Jung;Woo, Young-Jae;Lee, Hae-Jung;Jeon, Young-Ju;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1968_1969
    • /
    • 2009
  • 한의학에서 맥진을 하는 위치인 좌, 우 요골동맥상의 촌(寸), 관(關), 척(尺) 위치는 손목에 있는 요골 경상돌기(styloid preocess) 부근의 볼록한 지점인 고골(高骨)을 기준으로 맥이 느껴지는 위치를 검지, 중지, 약지를 이용해 찾는다. 각각의 위치는 한의학적인 관점에서 각기 다른 장부의 기능과 연결되며 그 차이를 인지하여 맥을 진단하는데 그 결과에 따라 병증을 진단하는 요소로 활용되게 된다. 그러나 생리학적으로 좌, 우 요골동맥의 차이는 크지 않다고 알려져 있으며 차이에 대한 연구도 많지 않다. 본 연구에서는 기존연구에서 밝혀진 좌, 우 요골동맥의 혈류속도의 차이를 근거로 한의사 맥진시 센서 역할을 하는 손가락에서 감지된 좌, 우 맥진위치의 차이가 실제 맥진기에서도 나타나는지를 측정을 통해 확인 해 보고자 한다. 건강한 20대 남자 135명을 대상으로 맥파를 측정하여 맥파 파라메터 중 차이를 보이는 파라메터를 통계분석하였다. 그 결과, 11개의 파라메터가 좌, 우 맥진위치에서 차이를 보이는 것을 확인하였다. 차이를 보이는 변수는 특정 변수로 한정되지 않고 맥압과 관련된 (h1~5) 변수와 피크가 나타나는 시간의 변수, 맥파 파형의 면적 등 다양한 변수에서 차이를 확인할 수 있었다.

  • PDF

Scientific Palpation Theory for the Manufacture of the Palpation Diagnosis Tool and Health Life (진맥기 제작과 생활의학 활용을 위한 과학적 진맥이론)

  • 장동순;신미수;백영수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.118-126
    • /
    • 2000
  • 동양의학에서 인체의 주된 생리 정보는 체질과 맥진에서 얻어질 수 있다 체질은 선천적인 오장 육부 기능에 대한 정보를 제공한다. 체질에 대한 판단은 얼굴형상, 맥진, 사주 등의 방법에 의한다. 반면에 진맥은 현재의 오장육부의 건강 상태를 나타낸다. 오장육부의 생체정보는 인체경락의 전기 전도도를 측정하는 방법에 의해서도 얻어질 수 있으나 본 논문에서는 진맥에의한 방법만을 토론한다. 체질과 진맥 정보는 치병에 있어서 처방의 기간과 강도를 결정 할 수 있는 결정적인 변수이다. 이 두가지 정보 중에서 하나라도 결핍될 경우 병에 대한 효율적인 대응이 어려워진다. 그 이유는 처방의 강약 조절이 어렵고 그 결과 다른 부작용 유발가능성이 크다. 본 논문에서는 진맥이론의 일반적 전개를 위하여 음양오행 성질의 과학적인 정의를 기초로 하였다. 구체적인 맥상의 판단에는 (1) 음의 맥과 양의 맥의 절대적 크기와 상대적 비(즉 음양의 강도와 비), (2) 오행의 성질에 기초한 맥의 형상, 그리고 (3) 맥의 느낌이나 성질등 3가지 정보를 종합한 방법으로 맥상을 파악한다. 이러한 맥진기술 이론은 분류방법이 간단할 뿐만아니라 이론이 일반적이다. 그래서 한의학의 전문가는 물론이고 일반인 모두 쉽게 익혀 덜인의 건강상태를 스스로 파악하는 것이 가능하다. 진맥기 제작의 기년 이론으로서 역할을 할 수 있다. 오행이론에 기초 할 경우 맥상은 5가지 대표적인 맥으로 분류된다. 맥의 이름은 황제내경에 제시된 한의학적인 이름과 함께 맥상을 쉽게 유추 할 수 있는 실생활적인 이름을 병용하였다. 예를 들어 위장이 약할 때 나타나는 홍맥을 진빵같이 부드러운 맥으로, 폐가 나쁠 때 나오는 흩어지는 모맥을 도우너츠형 연기맥으로, 신장이 나쁠 때 나오는 단단한 석맥을 고구마형상의 돌덩어리맥으로, 간이 나쁠 때 나오는 긴장된 현맥을 팽팽한 고무줄맥으로 그리고 심장이 나쁠 때 나오는 작고 연한 구맥을 튀어오르는 물방울맥으로 명명하였다. 이외에 진맥에 의하여 인체의 한열이나 지삭 부침등의 정보가 가능하며, 이러한 정보는 고혈압이나 중풍 확률, 비만 가능성 지수, 골다공증 선행지수 그리고 심장기능 파악(불전맥이나 대맥) 등 다양한 인체 정보를 파악하는 데 응용될 수 있음을 강조한다.

  • PDF

Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device (영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석)

  • Kim, Dong-Young;Lee, Sang-Suk;Hyeon, Seog-San;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.146-151
    • /
    • 2014
  • The pulse waveforms of a carotid artery in the neck and a radial artery in the hand wrist were individually measured by using clip-type pulsimeter equipped with a permanent and Hall device. The pulse transit time and the pulse wave velocity obtained through comparison of two pulse waveforms were analyzed each other. A value of the pulse wave velocity was about 8.5 m/s similar to one measured by a conservative method. This result suggests that the clip-type pulsimeter as the reproducible and reliable one oriental diagnostic medical device can be predicted to any atherosclerosis state in the cardiac circulatory system.