• Title/Summary/Keyword: 砂質土

Search Result 565, Processing Time 0.022 seconds

A study of Geotechnical Property of Stone Filler and Sewage Dredged Soil as Construction Materials (하수준설토와 석분의 건설재료로 재활용을 위한 지반물성연구)

  • Chung, Jae-Wook;Jang, Yeon-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.8-15
    • /
    • 2007
  • Geotechnical and environmental properties of stone fillers are analyzed by several laboratory experiment to identify the possibility of recycling fillers and sewage dredged soils as construction materials. The result of geotechnjical test shows that the sewage dredged soil is a sandy soil which contains 70-80% sand and is useful as an aggregate of construction site. Stone filler has large fine content, which may disqualifies the use as construction materials. However, this material is still useful as a filler in stone quarries or finished mines. From the environmental test, the liquids leached from two types of materials have satisfied the standard of chemical substances in the soil environment law and no harmful effect in ground pollution is expected when recycling.

A Study on the Lateral Behavior of Steel Pipe Piles in Centrifugal Test (원심모형실험에 의한 강관말뚝의 수평거동연구)

  • Kim, Yeong-Su;Seo, In-Sik;Kim, Byeong-Tak
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.5-20
    • /
    • 1996
  • This paper presents results from a series of model tests on laterally loaded single piles with both free-head and free-tip conditions. Model tests, using a centrifuge apparatus (middie size, Mark II in 7.1.7.) were carried out in sand based on the variation of different gravity acceleration and flexural stiffness of the pile and relative density of the soil. The aims of this study are to estimate the effect of gravity acceleratioil, flexordis stiffness, and relative density on the behavior of the pile embedded in Toyoura sand and to evaluate the applicability of a family of the p-y curves which was presented by several reseachers(Mur chison & O'Neill, neese et n., scott, Det worske veritas, nondner). The Program is deviloped by using p-y curves, and it can be used for the calculation of the displacement distri bution, bending moment distribution, and soil reaction distribution. By comparing meas ured responses with predicted one it is shown that the results of the p-y curve equation presented by Murchison & O'Neill and Kondner agreed with the general trend observed by the centrifuge tests much better than the numerical solutions predicted by the other sets of p -y curves.

  • PDF

Effect of Pile Head Constraint on Lateral Behavior of Single Rigid Pile in Two-Layered Sand Soil (2개층 사질토지반에서 단일 강성말뚝의 수평거동에 대한 두부 구속영향)

  • 김영수;서인식;김병탁;이상웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.217-224
    • /
    • 1999
  • This Paper shows the results of a series of model tests on the behavior of single rigid Pile, which subjected to lateral load, in non-homogeneous Nak-Dong River sands, consisted of two layers, upper and lower layers. The purpose of the present paper is to investigate the effect of ratio of lower layer thickness to embedded pile length ratio of soil modules of upper to lower layer (E$\sub$h1//E$\sub$h2/) and pile head constraint condition on the characteristics of lateral behavior of single pile. These effects can be quantified only by the results of model tests. As a model test result, in non-homogeneous sand, it shows that the lateral behavior depends upon the ratio of soil modules of upper to lower layer more than other factors. And, in respect of deflection, it was found that the reduction ratio of deflection by pile head fixity is the value of 0.5 and 0.6 for E$\sub$h1//E$\sub$h2/=0.18 and E$\sub$h1//E$\sub$h2/=5.56, respectively. The critical thickness of lower layer on the change of deflection is about 25 - 50% of pile embedded length. Also, in respect of maximum bending moment it was found that the reduction ratio of maximum bending moment by pile head fixity is the value of 0.55 and 0.7 for E$\sub$h1//E$\sub$h2/=0.18 and E$\sub$h1//E$\sub$h2/=5.56, respectively.

  • PDF

Effect of Visible Biopores on the Saturated Hydraulic Conductivity of Soil (가시 생물공극(生物孔隙)이 토양(土壤)의 투수계수(透水係數)에 미치는 영향(影響))

  • Park, Moo-Eon;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.14 no.2
    • /
    • pp.64-69
    • /
    • 1981
  • A field and laboratory experiments were conducted to evaluate the effect of visible biopores (larger than 0.2 mm in diameter) on the saturated hydraulic conductivity of Bonryang sandy loam (Coarse loamy over sandy, mixed, mesic family of Typic Udifluvents) developed on alluvial plains. The saturated hydraulic conductivity was significantly correlated with the equivalent permeble surface area (EPSA) which was calculated from the number of various sized biopores in the soil observed by naked eye, and negatively correlated with the bulk density. The effect of biopores on the saturated hydraulic conductivity was remarkable in subsoil al though it was not pronounced in plowed layer and sandy substrata. The bulk density was found to be correlated with the number and the EPSA of the visible biopores. A remarkable spatial variability was observed in the number of biopore and the bulk density.

  • PDF

Comparison of Extraction Methods for the Analysis of Total Petroleum Hydrocarbons in Contaminated Soil (오염토양내 석유계 총탄화수소 분석을 위한 추출방법의 비교)

  • Eui-Young Hwang;Wan Namkoong;Jung-Young Choi
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.2
    • /
    • pp.45-53
    • /
    • 2000
  • Two extraction methods for total petroleum hydrocarbon (TPH) from contaminated soil were evaluated. The soil used for this study was sandy loam. Diesel oil was selected as representative petroleum hydrocarbons and was spiked at 100, 10,000, 50,000mg TPH/kg dry soil. Percentage recovery of TPH by shaking method was higher compared to Soxhlet extraction. At extraction time of 2 hours and sample to solvent ratio of 1 : 5, the highest percentage recovery was obtained. In this condition, percentage recovery of TPH in soil contaminated with 100mg/kg and 50,000mg/kg as TPH was 95.9% and 95.5%, respectively The volume of solvent lost by volatilization in shaking method was relatively small compared to Soxhlet extraction.

  • PDF

Evaluation Technique of Ground Densification on Sand Deposit using SASW and Resonant Column Tests (표면파시험과 공진주시험을 이용한 사질토지반 개량평가 시스템의 개발)

  • 김동수;박형춘;김성인
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 1999
  • In order to assess the quality and depth of ground densification by compaction, SPT and/or CPT are performed before and after compaction. Both methods are intrusive and one point tests, require a substantial time to evaluate a large area, and their results are quite dependent on the operation technique and soil type. In this paper, the quality and extent of ground densification by compaction was evaluated by using in situ SASW test and laboratory resonant column (RC) test results. SASW test was used to determine the shear wave velocity profiles before and after compaction, and RC test was adopted to determine the correlation between the normalized shear wave velocity and the density of the site, which is almost uniquely independent of confinement. Testing and data reduction procedures of both tests were discussed, and a simplified evaluation procedure of ground densification was proposed. Finally, the feasibility of the proposed method was verified by performing field study at Inchon International Airport Project. Field densities determined by the proposed method matched well with those determined by sand cone tests.

  • PDF

Estimation of Bearing Capacity for Open-ended Pile in Sands Considering Soil Plugging (II) - Applicability of New Design Equation - (사질토지반에서 폐색효과를 고려한 개단말뚝의 지지력 산정 (II) - 새로운 지지력 산정식의 적용성 -)

  • 백규호
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.199-206
    • /
    • 2002
  • The bearing capacity of open-ended piles is affected by the degree of soil plugging, which is quantified by the incremental filling ratio, IFR. However, most design criteria for open-ended piles do not consider the variation of pile bearing capacity with IFR. In this study, new design equations for calculating the pile base and shaft load capacities, based on IFR value of the pile, were proposed using the results of model pile tests. A full-scale pile load test was also conducted on fully instrumented open-ended pile driven into gravelly sand. The IFR for the pile was continuously measured during pile driving. In order to check the accuracy of predictions made with the proposed equations, the equations were applied to two examples, including the pile load test preformed in this study. Based on the comparisons with the pile load tests results, the proposed equations appear to produce satisfactory predictions.

Uplift Behavior of Group Micropile according to Embedded Pile Condition in Sand (사질토지반에서 그룹 마이크로파일의 설치조건에 따른 인발거동특성)

  • Kyung, Doo-Hyun;Kim, Ga-Ram;Park, Dae-Sung;Kim, Dae-Hong;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.2
    • /
    • pp.27-37
    • /
    • 2015
  • The micropile is small diameter pile foundation of which diameter is below 300 mm. This system has been applied to reinforce the foundation structure. In the present study, the effects of embedded conditions of group micropiles were investigated from a series of uplift load tests. For the study, uplift load tests were performed using group micropiles in various pile spacing and installation angle. The increase of uplift resistance and the reduction of uplift displacement were investigated in the tests. As the result, the resistances were principally changed by embedded pile angle, the resistance increase were 33%, 59% and 5% for $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of embedded pile angle. The uplift displacement reduction increases with lower pile spacing condition and the reduction ratios of uplift displacements in the same spacing condition were 50%, 53%, -45% for $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of embedded pile angle.

A Study on the Soft Ground Subsidence beneath the Jack-up Rig Working for Offshore Wind Turbine Installation (해상풍력발전 설치를 위한 jack-up rig 작업 시 연약지반에 발생하는 지반침하에 관한 연구)

  • Lee, Eui-Chang;Jang, Won-Yil;Shin, Sung-Ryul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1136-1142
    • /
    • 2012
  • With concern for new renewable energy sources rising, the offshore wind turbine energy market is growing. In order to install offshore wind turbines safely in a harsh environment, jack-up rigs need to be used. Recently, a WTIV(Wind Turbine Installation Vessel), which has a self-propelling system, was developed to replace traditional jack-up rigs. Since the jack-up rig works at 60 meters of depth in offshore and the seafloor is composed mostly of soft clay and sand, it is necessary to conduct a stability examination for ground subsidence before using it. This study conducts an improved numerical analysis of the effect of jack-up rig loading on the soft ground by using FLAC3D considering consolidation theory. This includes analyzing the amount of subsidence when applying different cases of surchargings. It can be concluded that the mid-loading method has an advantage as regards clay layers and the pre-loading method has an advantage as regards sand layers.

Three-Dimensional Finite Element Analysis of Tieback Walls in Sand

  • Lim, Yu-Jin;Briaud, Jean-Louis
    • Geotechnical Engineering
    • /
    • v.13 no.3
    • /
    • pp.33-52
    • /
    • 1997
  • A three dimensional nonlinear finite element analysis is used to study the influence of various design decisions for tieback walls. The numerical model simulates the soldier piles and the tendon bonded length of the anchors with beam elements, the unbonded tendon with a spring element, the wood lagging with the shell elements, and the soil with solid 3D nonlinear elements. The soil model used is a modified hyperbolic model with unloading hysteresis. The complete sequence of construction is simulated including the excavation, and the placement and stressing of the anchors. The numerical model is calibrated against a full scale instrumented tieback wall at the National Geotechnical Experimentation Site (NGES) on the Riverside Campus of Texas A&M University. Then a parametric study is conducted. The results give information on the influence of the following factors on the wall behavior : location of the first anchor, length of the tendon unbonded zone, magnitude of the anchor forces, embedment of the soldier piles, stiffness of the wood lagging, and of the piles. The implications in design are discussed.

  • PDF