• Title/Summary/Keyword: ↑CSI

Search Result 469, Processing Time 0.033 seconds

A study on dosimetric comparison of craniospinal irradiation using tomotherpy and reproducibility of position (토모테라피를 이용한 뇌척수조사의 선량적 비교와 자세 재현성에 대한 고찰)

  • Lee, Heejeong;Kim, Jooho;Lee, Sangkyu;Yoon, Jongwon;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: The purpose of this study was to verify dosimetric results and reproducibility of position during craniospinal irradiation (CSI) using tomotherapy (Accuray Incorporated, USA). Also, by comparing with conventional CSI Technique, we confirmed the efficiency of using a Tomotherapy. Materials and Methods: 10 CSI patients who get tomotherapy participate. Patient-specific quality assurances (QA) for each patient are conducted before treatment. When treating, we took Megavoltage Computed Tomography (MVCT) that range of head and neck before treatment, L spine area after treatment. Also we conducted in-vivo dosimetry to check a scalp dose. Finally, we made a 3D conventional radiation therapy(3D-CRT) of those patients to compare dosimetric differences with tomotherapy treatment planning. Results: V107, V95 of brain is 0 %, 97.2 % in tomotherapy, and 0.3 %, 95.1 % in 3D-CRT. In spine, value of V107, V95 is 0.2 %, 18.6 % in tomotherapy and 89.6 %, 69.9 % in 3D-CRT. Except kidney and lung, tomotherapy reduced normal organ doses than 3D-CRT. The maximum positioning error value of X, Y, Z was 10.2 mm, -8.9 mm, -11.9 mm. Through in-vivo dosimetry, the average of scalp dose was 67.8 % of prescription dose. All patient-specific QA were passed by tolerance value. Conclusion: CSI using tomotherapy had a risk of parallel organ such as lung and kidney because of integral dose in low dose area. However, it demonstrated dosimetric superiority at a target and saved normal organ to reduce high dose. Also results of reproducibility were not exceeded margins that estimated treatment planning and invivo dosimetry showed to reduce scalp dose. Therefore, CSI using tomotherapy is considered to efficient method to make up for 3D-CRT.

  • PDF

Development of Real-Time Mental Work Load Measurement System using Heart Rate Variability base on Personal Computer (심박변화율을 이용한 PC 기반 실시간 정신작업부하 측정시스템 개발)

  • 고한우;윤용현;양희경;김동윤
    • Science of Emotion and Sensibility
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • The evaluation of mental workload is measured by subjective ratings, physiological signals. It takes long time to analysis the measured signals and is very tedious and time-consumming work. Therefore, to evaluate the affect of workload effectively, real-time measurement system is required. In this paper, real-time mental workload measurement system using cardiac autonomic indiced which reflect well the mental workload was developed and evaluated. Analyzed indices were HR, IBI, Lorentz plot, CSI, CVI, and LF/HF ratio of heart rate variability. The system was applied to evaluate the affect of arithmetic task and showed good results. This system was consisted of ECG amplifier, A/D converter, and personal computer, and algorithm was implemented using LabVIEW.

  • PDF

A Study on information structure of materials for green design -Based on the CSI MasterFormat- (그린 디자인을 위한 재료 정보 구조에 관한 연구)

  • 이현수;김은영
    • Korean Institute of Interior Design Journal
    • /
    • no.25
    • /
    • pp.290-294
    • /
    • 2000
  • Between multiple components of the building, materials have a direct impact on the environment. For many researchers have proposed guidelines for green design materials. However they didnt provide concrete criteria for selecting materials for selecting materials for achieving green design. From the perspective of this point, this paper proposes. Performance information expressed numerically is the most important factor. The purpose of this study is to provide the specific information about the performance of materials that has been ranked quantitatively. The performance information can be utilited in selecting materials for green design.

  • PDF

The Analysis and Simulation of Current Source Inverter-Induction Motor System Using Switching Function Representation (스위칭함수에 의한 전류형 인버어터 유도전동기 시스템의 해석 및 시뮬레이션)

  • 박민호;전태원;정승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.5
    • /
    • pp.185-192
    • /
    • 1986
  • This paper deals with the general mathmatical model of the CSI-fed induction motor system. The inverter is represented by a switching function matrix which is combined with the dg model of an induction motor. Complete system model is given by a set of differential equations in a closed form, which inherently includes the harmonic effects of the converter and the inverter. The model is valid in evaluating both the transient and steady state responses, while the more simple analytical model can be derived from the general model, in a steady state. With the model proposed, the digital simulation is carried out on a 10KVA CSI-induction motor system and the simulation results show good agreements with experimental ones.

  • PDF