• Title/Summary/Keyword: \gamma,\

Search Result 11,913, Processing Time 0.046 seconds

Effect of Mulberry Leaf Extract Supplement on Blood Glucose, Glycated Hemoglobin and Serum Lipids in Type II Diabetic Patients (상엽추출물이 제2형 당뇨병 환자의 혈당, 당화혈색소 및 혈청지질에 미치는 영향)

  • Yang, Jung-Hwa;Han, Ji-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.5
    • /
    • pp.549-556
    • /
    • 2006
  • The purpose of this study was to assess the effects of mulberry leaf extract supplement on blood glucose, glycated hemoglobin ($HbA_{1C}$) and serum lipids in type II diabetic patients, and also to assess safety in liver function after mulberry leaf extract supplement. The study was a randomized placebo-controlled trial and total 23 type II diabetic patients were divided into a MLE group taking 1,000 mg mulberry leaf extract supplement per day as experimental group and a placebo group taking 1,000 mg cellulose Powder supplement per day for 12 weeks. After 2 weeks of wash-out period, fasting blood glucose, $HbA_{1C}$, serum lipid levels and liver function test were analyzed before and after treatment of 12 weeks. The general baseline characteristics, nutrient intake and life style factors of study subjects were similar between two groups during intervention. The concentrations of fasting blood glucose and $HbA_{1C}$ (p<0.05) decreased significantly after mulberry leaf extract supplement in MLE group, while there were no changes found in placebo group. We also found it showed that mulberry leaf extract supplement for 12 weeks decreased significantly (p<0.05) the fasting blood glucose in poor fasting blood glucose group and $HbA_{1C}$ concentration in poor $HbA_{1C}$ group. The concentrations of LDL-cholesterol (p<0.05) and triglyceride (p<0.01) decreased significantly in MLE group after 12 weeks of taking the supplement, while there were no changes found in placebo group. The mulberry leaf extract supplement for 12 weeks didn't show hepatotoxicity. These results suggested that mulberry leaf extract supplement could be effective in improving fasting blood glucose and $HbA_{1C}$ levels in the diabetic patients, specially having high concentrations of fasting blood glucose and $HbA_{1C}$ among type II diabetic patients.

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

The Plan of Dose Reduction by Measuring and Evaluating Occupationally Exposed Dose in vivo Tests of Nuclear Medicine (핵의학 체내검사 업무 단계 별 피폭선량 측정 및 분석을 통한 피폭선량 감소 방안)

  • Kil, Sang-Hyeong;Lim, Yeong-Hyeon;Park, Kwang-Youl;Jo, Kyung-Nam;Kim, Jung-Hun;Oh, Ji-Eun;Lee, Sang-Hyup;Lee, Su-Jung;Jun, Ji-Tak;Jung, Eui-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.26-32
    • /
    • 2010
  • Purpose: It is to find the way to minimize occupationally exposed dose for workers in vivo tests in each working stage within the range of the working environment which does not ruin the examination and the performance efficiency. Materials and Methods: The process of the nuclear tests in vivo using a radioactive isotope consists of radioisotope distribution, a radioisotope injection ($^{99m}Tc$, $^{18}F$-FDG), and scanning and guiding patients. Using a measuring instrument of RadEye-G10 gamma survey meter (Thermo SCIENTIFIC), the exposure doses in each working stage are measured and evaluated. Before the radioisotope injection the patients are explained about the examination and educated about matters that require attention. It is to reduce the meeting time with the patients. In addition, workers are also educated about the outside exposure and have to put on the protected devices. When the radioisotope is injected to the patients the exposure doses are measured due to whether they are in the protected devices or not. It is also measured due to whether there are the explanation about the examination and the education about matters that require attention or not. The total exposure dose is visualized into the graph in using Microsoft office excel 2007. The difference of this doses are analyzed by wilcoxon signed ranks test in using SPSS (statistical package for the social science) program 12.0. In this case of p<0.01, this study is reliable in the statistics. Results: It was reliable in the statistics that the exposure dose of injecting $^{99m}Tc$-DPD 20 mCi in wearing the protected devices showed 88% smaller than the dose of injecting it without the protected devices. However, it was not reliable in the statistics that the exposure dose of injecting $^{18}F$-FDG 10 mCi with wearing protected devices had 26% decrease than without them. Training before injecting $^{99m}Tc$-DPD 20 mCi to patient made the exposure dose drop to 63% comparing with training after the injection. The dose of training before injecting $^{18}F$-FDG 10 mCi had 52% less then the training after the injection. Both of them were reliable in the statistics. Conclusion: In the examination of using the radioisotope $^{99m}Tc$, wearing the protected devices are more effective to reduce the exposure dose than without wearing them. In the case of using $^{18}F$-FDG, reducing meeting time with patients is more effective to drop the exposure dose. Therefore if we try to protect workers from radioactivity according to each radioisotope characteristic it could be more effective and active radiation shield from radioactivity.

  • PDF

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Comparison of the Uptakes of Tc-99m MIBI and Tc-99m Tetrofosmin in A549, an MRP-expressing Cancer Cell, In Vitro and In Vivo (MRP발현 인체 비소세포 폐암 A549에서 Tc-99m MIBI와 Tc-99m Tetrofosmin섭취의 비교)

  • Yoo, Jeong-Ah;Jeong, Shin-Young;Seo, Myung-Rang;Bae, Jin-Ho;Ahn, Byeong-Cheol;Lee, Kyu-Bo;Choi, Sang-Woon;Lee, Byung-Ho;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.382-392
    • /
    • 2003
  • Purpose: Uptakes of Tc-99m MIBI (MIBI) and Tc-99m tetrofosmin (tetrofosmin) in human non-small cell lung cancer A549, multidrug-resistance associated protein (MRP) expressing cell, were investigated in vitro and in vivo. Materials and Methods: Western blot analysis and immunohistochemistry were used for detection of MRP in A549 cells with anti-MRPr1 antibody. Cellular uptakes of two tracers were evaluated at $100{\mu}M$ of verapamil (Vrp), $50{\mu}M$ of cyclosporin A (CsA) and $25{\mu}M$ of butoxysulfoximide (BSO) after incubation with MIBI and tetrofosmin for 30 and 50 min at $37^{\circ}C$, using single cell suspensions at $1{\times}10^6cells/ml$. Radioactivities in supernatants and pellets were measured with gamma well counter. A549 cells were inoculated in each flanks of 24 nude mice. Group 1 (Gr1) and Gr3 mice were treated with only MIBI or tetrofosmin, and Gr2 and Gr4 mice were treated with 70mg/kg of CsA i.p. for 1 hour before injection of 370KBq of MIBI or tetrofosmin. Mice were sacrificed at 10, 60 and 240 min. Radioactivities of organs and tumors were expressed as percentage injected dose per gram of tissue (%ID/gm). Results: Western blot analysis of the A549 cells detected expression of MRPr1 (190 kDa) and immunohistochemical staining of tumor tissue for MRPr1 revealed brownish staining in cell membrane but not P-gp. Upon incubating A549 cells for 60 min with MIBI and tetrofosmin, cellular uptake of MIBI was higher than that of tetrofosmin. Coincubation with modulators resulted in an increase in cellular uptakes of MIBI and tetrofosmin. Percentage increase of MIBI was higher than that of tetrofosmin with Vrp by 623% and 427%, CsA by 753% and 629% and BSO by 219% and 140%, respectively. There was no significant difference in tumoral uptakes of MIBI and tetrofosmin between Gr1 and Gr3. Percentage increases in MIBI (114% at 10 min, 257% at 60 min, 396% at 240 min) and tetrofosmin uptake (110% at 10 min, 205% at 60 min, 410% at 240 min) were progressively higher by the time up to 240 min with CsA. Conclusion: These results indicate that MIBI and tetrofosmin are suitable tracers for imaging MRP-mediated drug resistance in A549 tumors. MIBI may be a better tracer than tetrofosmin for evaluating MRP reversal effect of modulators.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Effect of Retrovirus Mediated TNF-$\alpha$ Gene Transfer to Tumor Necrosis Factor(TNF) Sensitive Tumor Cell Lines on Sensitivity to TNF (Retroviral Vector를 이용한 TNF-$\alpha$ 유전자의 이입이 암세포의 종양괴사인자(TNF) 감수성에 미치는 효과)

  • Oh, Yeon-Mok;Park, Kyeo-Yeong;Jung, Man-Pyo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Goo;Sim, Young-Soo;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.87-96
    • /
    • 1994
  • Background : Since tumor necrosis factor was discovered in 1975, TNF has been well known about its cytotoxic effect on tumor cells in vivo and in vitro. According to the recent improvement of molecular biological techinques, it is possible that exogenous TNF gene is transferred to tumor cells and is expressed in theirs. By virtue of TNF gene transfer, we have expected that TNF expressed in TNF-gene-transferred tumor cells would kill tumor cells in vivo without systemic side effect. The expected mechanisms in which antitumor effects of TNF expressed in TNF-gene-transferred tumor cells are working would be as followings. In the first mechanism, TNF expressed in TNF-gene-transferred tumor cells would kill tumor cells around(like homicide). In the second mechanism, TNF expressed in TNF-gene-transferred tumor cells would kill themselves(like suicide). In the third mechanism, TNF expressed in TNF-gene-transferred tumor cells would recruit immune effector cells and kill tumor cells indirectly. In the last mechanism, TNF expressed in TNF-gene-transferred tumor cells would augment cytokine such as interferon-$\gamma$ to kill tumor cells. Among these four mechanisms of antitumor effect, only the second mechanism has not been established yet. Therefore, to elucidate the second mechanism, We performed this study. Method : We transferred TNF-$\alpha$ gene to NCI-H2058, a human mesothelioma cell line and WEHI164, a murine fibrosarcoma cell line by using retroviral vector(pLT12SNTNF). And, We determined by using MTT assay whether TNF expressed in TNF-gene-transferred tumor cell lines would kill themselves like suicide or not. Then, if TNF-gene-transferred tumor cell lines would not suicide themselves, I would know more about the TNF sensitivity of TNF-gene-transferred tumor cell lines to exogenous TNF also by MTT assay. Result : NCI-H2058 and WEHI164 which were sensitive to TNF, became far less sensitive to endogenous and exogenous TNF after being transferred TNF-$\alpha$ gene to. Conclusion : TNF-gene-transfer to NCI-H2058 and WEHI164 gave them resistance to TNF.

  • PDF